一、中兴9210设备:

1、登陆设备:telnet X.X.X.X 输入用户名和密码即可登录

2、查看设备板卡:

yl-xyx-kltb9210-01-01# show card*******查看设备板卡(如下:ASIGB和ASIGC为用户板)

Slot CardType CardState RunCardType SoftVer PortNum PortType

------------------------------------------------------------------------

1 ASIGB UP ASIGB 3.5h 3

2 ADSL2/MPVC

2 ASIGB UP ASIGB 3.5h 32 ADSL2/MPVC

3 ASIGC UP ASIGC 3.4f 32 ADSL2/MPVC

4 NONE DOWN NONE 0 none

5 NONE DOWN NONE 0 none

6 NONE DOWN NONE 0 none

7 NONE DOWN NONE 0 none

8 NONE DOWN NONE 0 none

MAIN SCB MASTER SCB 5.0.0P5T1 0 none

BAK NONE DOWN NONE 0 none

9 NONE DOWN NONE 0 none

10 NONE DOWN NONE 0 none

11 NONE DOWN NONE 0 none

12 NONE DOWN NONE 0 none

13 NONE DOWN NONE 0 none

14 NONE DOWN NONE 0 none

15 NONE DOWN NONE 0 none

16 GFHA UP GFHA 8 ETHER

2、查看模板:

①yl-xyx-kltb9210-01-01# show adsl profile ****查看端口可以引用的设备模板

All existed Line Profile:

-------------------------

DEFV AL.PRF

DEF8M.PRF

DEF2M.PRF

DEF1M.PRF

DEFHM.PRF

ADSL1M512K.PRF

ADSL2M512K.PRF

ADSL3M512K.PRF

ADSL4M512K.PRF

ADSL3M256K.PRF

ADSL8M512K.PRF

1M512K.PRF

2M512K.PRF

3M512K.PRF

4M512K.PRF

5M512K.PRF

6M512K.PRF

7M512K.PRF

8M512K.PRF

4068K512K.PRF

12M512K.PRF

20M512K.PRF

ADSL10M768K.PRF

ADSL12M768K.PRF

ADSL16M1024K.PRF

ADSL20M1024K.PRF

8M640K.PRF

ADSL4928K.PRF

ADSL9856K640K.PRF

ADSL14752K768K.PRF

ADSL2688K512K.PRF

ADSL8608K640K.PRF

ADSL672K192K.PRF

ADSL1344K512K.PRF

ADSL7392K640K.PRF

ADSL6144K640K.PRF

ADSL4000K512K.PRF

②yl-xyx-kltb9210-01-01#

查看端口可以引用的具体的设备模板(以ADSL9856K640K.PRF为例)****** show adsl profile ADSL9856K640K.PRF AtucConfRateMode : adaptAtStartup

AtucConfRateChanRatio : 0 AtucConfTargetSnrMgn : 80 AtucConfMaxSnrMgn : 310 AtucConfMinSnrMgn : 0 AtucConfDownshiftSnrMgn : 0 AtucConfUpshiftSnrMgn : 0 AtucConfMinUpshiftTime : 0 AtucConfMinDownshiftTime : 0 AtucChanConfFastMinTxRate: 32 AtucChanConfInterMinTxRate: 32 AtucChanConfFastMaxTxRate: 9856 AtucChanConfInterMaxTxRate: 9856 AtucChanConfMaxInterDelay: 16

AturConfRateMode : adaptAtStartup

AturConfRateChanRatio : 0 AturConfTargetSnrMgn : 80 AturConfMaxSnrMgn : 310 AturConfMinSnrMgn : 0 AturConfDownshiftSnrMgn : 0 AturConfUpshiftSnrMgn : 0 AturConfMinUpshiftTime : 0 AturConfMinDownshiftTime : 0 AturChanConfFastMinTxRate: 32 AturChanConfInterMinTxRate: 32 AturChanConfFastMaxTxRate: 640 AturChanConfInterMaxTxRate: 640 AturChanConfMaxInterDelay : 16

-----------------------------------------------------------

adslAtucDMTConfFreqBins:

[ 0] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 16] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 32] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 48] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON adslAturDMTConfFreqBins:

[ 0] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 16] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 32] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 48] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 64] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 80] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [ 96] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [112] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [128] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [144] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [160] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [176] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [192] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [208] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [224] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [240] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [256] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [272] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [288] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [304] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [320] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [336] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [352] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [368] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [384] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [400] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [416] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON [432] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

[448] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

[464] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

[480] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

[496] ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON LineDMTConfEOC : byte

ConfProfileLineType : interleavedOnly

LineDMTConfTrellis : on

AtucConfMaxBitsPerBin : 15

AtucConfTxStartBin : 6

AtucConfTxEndBin : 511

AtucConfRxStartBin : 6

AtucConfRxEndBin : 31

AtucConfUseCustomBins: disable

AtucConfDnBitSwap : disable

AtucConfUpBitSwap : disable

AtucConfREADSL2Enable: disable

AtucConfPsdMaskType : 275

AtucConfPMMode : L2&L3-disable

AtucConfPML0Time(second) : 240

AtucConfPML2Time(second): 120

AtucConfPML2ATPR(dB) : 3

AtucConfPML2Rate(kbps): 512

AtucConfMinINP : 2

AturConfMinINP : 2

yl-xyx-kltb9210-01-01#

3、yl-xyx-kltb9210-01-01# show adsl status slot 1*****查看1槽位的所有端口状态和引用的速率模板以及实际可达的端口速率

Port Admin Link Up Down Profile

(kbps)(kbps)

----------------------------------------------------------------------------

1/1 enable down 0 0 ADSL14752K768K.PRF

1/2 enable up 637 9853 ADSL9856K640K.PRF

1/3 enable up 637 8605 ADSL8608K640K.PRF

1/4 disable down 0 0 ADSL8M512K.PRF

1/5 enable up 512 4096 ADSL4M512K.PRF

1/6 enable down 0 0 ADSL14752K768K.PRF

1/7 enable up 766 14751 ADSL14752K768K.PRF

1/8 enable up 766 14751 ADSL14752K768K.PRF

1/9 enable up 638 8192 ADSL8M512K.PRF

1/10 enable up 640 8096 ADSL8M512K.PRF

1/11 enable up 766 14748 ADSL14752K768K.PRF

1/12 enable up 766 14751 ADSL14752K768K.PRF

1/13 enable down 0 0 ADSL4M512K.PRF

1/14 enable down 0 0 ADSL3M512K.PRF

1/15 enable up 509 4927 ADSL4928K.PRF

1/16 enable up 766 14751 ADSL14752K768K.PRF

1/17 enable up 506 4095 ADSL4M512K.PRF

1/18 enable down 0 0 8M512K.PRF

1/19 enable up 638 8192 8M512K.PRF

1/20 enable up 512 4096 ADSL4M512K.PRF

1/21 disable down 0 0 ADSL14752K768K.PRF

1/22 enable down 0 0 ADSL4M512K.PRF

1/23 disable down 0 0 ADSL4M512K.PRF

1/24 enable up 512 4096 ADSL4M512K.PRF

1/25 enable up 512 4096 ADSL4M512K.PRF

1/26 enable down 0 0 ADSL3M256K.PRF

1/27 disable down 0 0 ADSL8M512K.PRF

1/28 enable up 640 8160 ADSL8M512K.PRF

1/29 enable up 509 4095 ADSL4M512K.PRF

1/30 enable down 0 0 ADSL4M512K.PRF

1/31 enable up 506 3072 ADSL3M512K.PRF

1/32 enable up 248 3070 ADSL3M256K.PRF

End

举例解释:如上的

Port Admin Link Up Down Profile

(kbps) (kbps)

----------------------------------------------------------------------------

1/3 enable up 637 8605 ADSL8608K640K.PRF

1/4 disable down 0 0 ADSL8M512K.PRF

*********

⑴1/3端口的释意为:端口为的打开状态(enable);而且为激活状态(UP);端口引用的模板为:ADSL8608K640K.PRF;用户实际可达的速率为:上行(up)637kbps;下行(down)8605kbps;

⑵1/4端口的释意为:端口为的关闭状态(disable);而且不在线状态(down);端口引用的模板为:

ADSL8M512K.PRF;因为用户未在线,端口没有激活,因此用户实际可达的速率均为0(即不可知);

3、打死激活端口及更改端口速率:(以端口1/1为例);

yl-xyx-kltb9210-01-01(config)# interface dsl-mpvc 1/1 *****进入1/1端口

DSL(config)# interface adsl 1/1 *********中兴9806E时进入单板的命令

①打死端口1/1

yl-xyx-kltb9210-01-01(cfg-if-dsl(m)-1/1)# shutdown

②激活端口1/1

yl-xyx-kltb9210-01-01(cfg-if-dsl(m)-1/1)# no shutdown

③更改端口速率(即引用模板)**除8220以外的其他设备

yl-xyx-kltb9210-01-01(cfg-if-dsl(m)-1/1)# adsl profile ADSL4928K512K.PRF

注意:引用的速率模板必须为集团要求的模板,见后附件;

中兴8220设备:

ZHAOSU# conf adsl profile 1/1 ADSL8608K640K.PRF

4、复位单板:(注意:只能对用户单板进行复位,而且在此用户单板上的用户均不正

常的情况下才能做)。

yl-xy-XianJu-9210-01-01# reset card 1 ****意为对1槽位用户板进行复位

5、保存命令:

DSL# ena

Password:

DSL$ copy run start

Are you sure to save configuration data? [y/n]y

Save finished successfully.

中兴8220设备的保存命令为:

/# save

Please wait for a while:

Save success!

6、退出命令:

DSL$ logout

退出成功后,显示“Connection closed by foreign host.”

以上命令,中兴9210和9806E设备命令除进入单板的命令不同(如上),其他命令基本相同。

二、中兴9800和9806H设备和其他设备不同的命令(其他命令均相同):

1、端口1/1的状态查看:

yl_xyx_71t3lzx9806h# show interface 1/1 port-status

Port AdminStatus LinkStatus AtucTxRate(kbps) AturTxRate(kbps)

-----------------------------------------------------------------

1/1 enable up 4096 512

2、端口1/1-24的状态查看(即第一槽位所有端口查看):adsl line-profile ADSL4928K512K.PRF

yl_xyx_71t3lzx9806h# show interface 1/1-24 port-status show adsl status slot 1 Port AdminStatus LinkStatus AtucTxRate(kbps) AturTxRate(kbps)

-----------------------------------------------------------------

1/1 enable up 4096 512

1/2 enable up 9856 636

1/3 enable down N/A N/A

1/4 enable up 4096 512

1/5 enable down N/A N/A

1/6 enable down N/A N/A

1/7 enable down N/A N/A

1/8 enable down N/A N/A

1/9 enable down N/A N/A

1/10 enable down N/A N/A

1/11 enable up 9853 636

1/12 disable down N/A N/A

1/13 enable down N/A N/A

1/14 enable down N/A N/A

1/15 disable down N/A N/A

1/16 enable down N/A N/A

1/17 enable down N/A N/A

1/18 enable down N/A N/A

1/19 enable down N/A N/A

1/20 enable up 9855 636

1/21 enable up 9855 636

1/22 enable up 9855 636

1/23 enable down N/A N/A

1/24 enable up 4096 512

3、中兴9800设备增加了端口状态、端口最大可达速率、实际可达速率以及信噪比和衰耗值和输出的上下行功率的命令,命令如下:

①yl-62tuan-zx9800-01-01# show interface 2/1-12 adsl-status

Port Link CurrRate AttainableRate SnrMgn Atn OutPwr

Status down/up(k) down/up(k) down/up down/up down/up

----------------------------------------------------------------------

2/1 up 8191/509 12560/943 218/164 101/225 163/119

2/2 down 0/0 0/0 0/0 0/0 0/0

2/3 up 8191/509 25384/1148 280/328 109/230 147/122

2/4 down 0/0 7200/1024 256/180 183/324 195/121

②其中中兴8220设备查看端口的实际可达速率及衰减值等方法如下:

ZHAOSU# show interface 2/1-32 brief (这是查看2槽位第1至32端口的状态,也可以只看一个端口如:show interface 2/1 brief ,如没有显示,则表明端口没有在线)

③简单查看端口状态和目前引用的速率模板的方法:

show adsl status 2/1

----------------------------------------

ADSL LINE STATUS OF CARD 2 PORT 1 INFO: LineCoding..............................G.dmt LineType................................interleavedOnly LineSpecific. 0

LineConfProfile.........................ADSL4M512K.PRF LineAlarmConfProfile....................DEFV AL.PRF AdminStatus.............................up

OperStatus..............................down

TestStatus..............................NONE

三、查看设备的读写团体字,读写团体字的作用:在新开设备时及时添加至IP综合网管,并必须填写可读可写的团体字,否则,设备和综合网管不能通信,端口的自动停开机等将无法执行):

Show snmp community

1、中兴8220设备查看团体字:

/# show community

access-level communityname

-------------------------------------------

read xjtelecom

read&write yltelecom

2、中兴9800和9210设备及其他中兴设备SNMP团体字的查看:

yl-glx-chengxi9800-01-01# show snmp

Trap IP List

1 : 218.31.66.94

2 : 61.128.107.216

3 : 222.83.23.41

4 : 222.83.23.43

5 : 222.82.255.41

6 : 222.82.255.40

-------------------------------------------------------

Community List

1 : xjtelecom read-only

2 : yltelecom read-write

中兴9210团体字查看及显示结果:

yl-zs-kalasu-9210-01-01# show snmp

Snmp Community:

CommName Permission ViewName

--------------------------------------------------------------------- xjtelecom readOnly public yltelecom readWrite public

Trap Community:

Community IpAddress SnmpVer BaseType zteNms

---------------------------------------------------------------------

inittrap 136.1.4.71 2 trap false

public 218.31.66.94 2 trap false

public 218.84.40.66 2 trap false

IPzhwg 222.83.23.41 2 trap false

IPzhwg 222.83.23.43 2 trap false

四、华为5600设备:

1、查看设备板卡:

yl-yn-dxy-ma5600-A01#display board 0

-------------------------------------------------------------------------

SlotID BoardName Status SubType0 SubType1

-------------------------------------------------------------------------

0 H568ADGE Normal

1 H56AADGE Normal

2 H56AADGE Normal

3 H56AADGE Normal

4 H56AADGE Normal

5 H56AADGE Normal

6 H56AADGE Normal

7 H561SCUB Active_normal O2GS O2GS

8

9 H56AADGE Normal

10 H56AADGE Normal

11 H56AADGE Normal

12 H56AADGE Normal

13 H56AADGE Normal

14 H56AADGE Normal

15 H56AADGE Normal

2、查看模板:

①yl-yn-dxy-ma5600-A01#display adsl line-profile

{ |profile_index<1,1002> }:

Command:

display adsl line-profile

------------------------------------------------------------------------------

Profile Profile Operating Channel Min Down Max Down Min Up Max Up

Index Name Mode Mode Rate Rate Rate Rate

------------------------------------------------------------------------------

1 DEFVAL All Interleaved 3

2 6144 32 640

112 112 All Interleaved 32 9856 32 640

113 113 All Fast 32 672 32 192

114 114 All Fast 32 1344 32 512

115 115 All Fast 32 2688 32 512

116 116 All Fast 32 4928 32 512

117 117 All Interleaved 32 8608 32 640

118 118 All Interleaved 32 14752 32 768

119 119 All Interleaved 32 22528 32 1024

120 120 All Interleaved 32 20480 32 1024

121 121 All Interleaved 32 16384 32 1024

122 122 All Fast 32 4096 32 512

123 123 All Interleaved 32 8192 32 640

124 124 All Interleaved 32 10240 32 768

125 125 All Interleaved 32 12288 32 768

444 444 All Fast 32 8608 32 640

1000 ADSL LINE All Fast 32 6144 32 640

PROFILE 10

00

------------------------------------------------------------------------------

Total: 64

Note : The unit of rate is Kbps

②查看端口可以引用的具体的设备模板

yl-yn-dxy-ma5600-A01# display adsl line-profile 112 (以ADSL9856K640K索引号为112的为例) -----------------------------------------------------------------------------

Profile index :112 Name: 112

ADSL transmission mode : All(G992.1~5,T1.413)

Trellis mode : Enable

Upstream channel bit swap : Enable

Downstream channel bit swap : Enable

Channel mode : Interleaved

Maximum downstream interleaved delay(ms) : 16

Maximum upstream interleaved delay(ms) : 6

Target downstream SNR margin(dB) : 6

Maximum acceptable downstream SNR margin(dB) : 31

Minimum acceptable downstream SNR margin(dB) : 0

Target upstream SNR margin(dB) : 6

Maximum acceptable upstream SNR margin(dB) : 31

Minimum acceptable upstream SNR margin(dB) : 0

Downstream SNR margin for rate downshift(dB) : 0

Downstream SNR margin for rate upshift(dB) : 0

Upstream SNR margin for rate downshift(dB) : 0

Upstream SNR margin for rate upshift(dB) : 0

Minimum upshift time in downstream(seconds) : 0

Minimum downshift time in downstream(seconds) : 0

Minimum upshift time in upstream(seconds) : 0

Minimum downshift time in upstream(seconds) : 0

Downstream form of transmit rate adaptation : Adapting at startup

Minimum transmit rate downstream(Kbps) : 32

Maximum transmit rate downstream(Kbps) : 9856

Minimum transmit rate upstream(Kbps) : 32

Maximum transmit rate upstream(Kbps) : 640

------------------------------------------------------------

3、查看1槽位的所有端口状态和引用的速率模板以及实际可达的端口速率yl-yn-dxy-ma5600-A01#display board 0/1

---------------------------------------

Board Name : H56AADGE

Board Status : Normal

Port Port Type Port Status Line Profile Alarm Profile Ext Profile

-----------------------------------------------------------------------------

0 ADSL Activating 7 1 --

1 ADSL Activated 125 1 --

2 ADSL Deactivated 118 1 --

3 ADSL Activated 44

4 1 --

4 ADSL Activated 19 1 --

5 ADSL Activating 125 1 --

6 ADSL Activated 118 1 --

7 ADSL Activated 125 1 --

8 ADSL Activated 117 1 --

9 ADSL Activating 125 1 --

10 ADSL Activated 38 1 --

11 ADSL Activated 38 1 --

12 ADSL Activated 125 1 --

13 ADSL Activated 19 1 --

14 ADSL Activating 7 1 --

15 ADSL Activated 7 1 --

16 ADSL Activated 118 1 --

17 ADSL Activated 38 1 --

18 ADSL Activated 118 1 --

19 ADSL Activated 118 1 --

20 ADSL Activated 7 1 --

21 ADSL Activated 46 1 --

22 ADSL Activating 118 1 --

23 ADSL Activated 117 1 --

24 ADSL Deactivated 7 1 --

25 ADSL Activating 444 1 --

26 ADSL Activated 13 1 --

27 ADSL Activated 38 1 --

28 ADSL Activating 444 1 --

29 ADSL Activated 19 1 --

30 ADSL Activated 125 1 --

31 ADSL Activating 7 1 --

-----------------------------------------------------------------------------

Total number of activated port : 22

Total number of unactivated port: 10

3、华为5600设备特有的在线端口实际可达速率、最大可达速率以及衰减值和信噪比、

输出功率值等查看(以1槽位为例)

①yl-yn-dxy-ma5600-A01(config)#interface adsl 0/1 **进入单板1槽位

②yl-yn-dxy-ma5600-A01(config-if-adsl-0/1)#display line operation all **显示在线端口以上各项信息的命令

{ || }:

Command:

display line operation all

It will take several minutes, and console may be timeout, please use command idle-timeout to set time limit

Are you sure to continue? (y/n)[n]:y

yl-yn-dxy-ma5600-A01(config-if-adsl-0/1)# ****以下各项含义和中兴设备相同,具体释意参考前面

----------------------------------------------------------------------------

Xdsl UpNoise DwNoise Up Stream Dw Stream MaxUp MaxDw UpOut DwOut Up Dw

Port Margin Margin attenuate attenuate Rates Rates Power Power Rates Rates

---- ------- ------- --------- --------- ----- ----- ----- ----- ----- -----

1 18.5 16.6 9.5 19.0 1189 23820 11.5 20.

2 766 12288

3 20.0 27.8 4.0 11.0 1158 22000 5.

4 20.3 638 8607

4 19.

5 25.9 5.5 7.9 1217 2239

6 1.6 12.3 640 8192

6 13.5 11.4 15.0 32.5 1054 17996 11.

7 20.3 766 14751

7 13.5 12.8 10.5 21.5 1066 19484 9.7 11.7 766 12287

8 20.0 20.4 11.0 20.0 1227 18480 11.8 18.3 640 8608

10 24.0 30.0 6.0 9.5 966 7761 10.8 14.2 512 4096

11 7.0 26.5 13.0 22.0 416 7761 11.0 19.6 416 4096

12 16.0 22.2 7.5 17.5 1154 21920 9.7 20.3 766 12287

13 20.5 27.1 12.0 25.5 1153 22676 11.7 20.3 637 8191

15 22.0 17.5 6.0 10.0 1024 8096 11.7 15.6 640 8096

16 13.5 10.0 9.0 18.8 1062 20136 7.8 9.7 766 14751

17 24.0 30.7 5.0 19.8 1155 22056 7.3 17.6 506 4091

18 13.5 8.7 16.0 36.0 1062 19196 11.7 20.3 766 14751

19 15.5 16.4 5.5 18.4 1114 22156 7.8 20.2 766 14751

20 16.5 11.5 7.0 12.5 932 8064 11.5 19.6 640 8064

21 24.0 30.3 11.0 22.5 1153 22672 11.4 20.3 510 4928

23 17.0 14.9 6.0 11.2 1041 20404 5.0 4.7 637 8607

26 20.5 34.0 9.5 18.5 1157 22452 11.7 17.8 637 3072

27 20.5 31.0 7.5 9.5 879 7761 10.8 17.6 512 4096

29 18.5 17.8 16.5 35.0 1078 17192 11.6 20.3 637 8191

30 13.5 16.9 14.5 28.0 1065 21616 11.6 20.3 766 12287

----------------------------------------------------------------------------

Notice: The port not displayed is not activated

4、打死激活端口和速率模板的引用:(以1槽位0端口为例,即端口为0/1/0);

①yl-yn-dxy-ma5600-A01(config)#interface adsl 0/5 **进入单板1槽位

②yl-yn-dxy-ma5600-A01(config-if-adsl-0/1)#deactivate 0 **打死0/1/0号端口

③yl-yn-dxy-ma5600-A01(config-if-adsl-0/1)#activate 0 ***激活0/1/0号端口

④yl-yn-dxy-ma5600-A01(config-if-adsl-0/1)#activate 9 profile-index 51 **将端口0/1/0的速率由7号模板改为112号索引的速率模板(即8192-640K的速率改为9856-640k)注意:速率模板引用必须先打死才能够引用新的模板

5、复位套片:(此命令使用的前提为:如果1块板子连续的8个、16个或24个、32个端口不正常,则可以进行套片复位进行尝试)可以理解为前半块和后半块单板,所以前半块单板的套片为0,后板块单板的套片为1;以0套片为例(进入单板下操作)

yl-yn-dxy-ma5600-A01(config-if-adsl-0/1)#chipset reset 0 **复位单板的前16个端口

5、复位单板(在全局下,进入config下做):

yl-yn-dxy-ma5600-A01(config)#board reset 0/1

6、保存数据

yl-yn-dxy-ma5600-A01#save

{ |configuration }:

7、退出:

yl-yn-dxy-ma5600-A01#quit

Check whether system data has changed. Please save data before logout. Are you sure to log out? (y/n)[n]:y

一定注意:所有设备做完操作后一定要做保存和退出命令,如果没有正常退出,则会出现设备吊死的情况。

五、OLT设备一些常用的查看命令:

1、查看单板:

中兴OLT:yl-bayandaic220#show card

华为OLT:①进入enable模式:yl-yn-81ju-MA5680T-01-01>enable

②查看单板:yl-yn-81ju-MA5680T-01-01#display board 0

2、查看设备配置:

中兴olt:yl-bayandaic220#show run

华为olt:在进入enbale模式后:yl-yn-81ju-MA5680T-01-01#display current-configuration

3、查看注册的ONU:《此命令也可以用来确定光猫注册不上来时的PON口是否不正确等。》

①中兴OLT:yl-bayandaic220#show onu unauthentication

②华为OLT:yl-yn-81ju-MA5680T-01-01#display ont autofind all

------------------------------------------------------------------------

Number : 1

F/S/P : 0/5/1

Ont Mac : 0026-ED7E-EAF2

Password :

Loid : 0026ed7eeaf2

Checkcode : 1111

VenderID : ZTE

Ontmodel : F400

OntSoftwareVersion : V1.1.0c_ZL2

OntHardwareVersion : V1.0.0

Ont autofind time : 2012-01-24 20:31:05+08:00

***通过以上命令可以看到,被发现的光猫以及光猫的MAC地址和通过哪个PON口上来的,如果没有发现则没有显示。

③查看PON口的配置(如果为FTTH,则可以看到数据下发到PON口上的情况,以0/6/1PON 口为例:

yl-yn-81ju-MA5680T-01-01# display current-configuration port 0/6/1

或简单显示被下发的业务:yl-80ju-MA5680T-2#display service-port port 0/1/0

{ |autosense|ont|sort-by }:

Command:

display service-port port 0/1/0

Switch-Oriented Flow List

----------------------------------------------------------------------------

INDEX VLAN VLAN PORT F/ S/ P VPI VCI FLOW FLOW RX TX STATE

ID ATTR TYPE TYPE PARA

----------------------------------------------------------------------------

55 2010 QinQ epon 0/1 /0 1 - vlan 46 10 10 up

56 1010 QinQ epon 0/1 /0 1 - vlan 45 8 11 up

58 10 QinQ epon 0/1 /0 1 - vlan 41 7 7 up

60 3010 QinQ epon 0/1 /0 1 - vlan 43 9 9 up

----------------------------------------------------------------------------

如果查到有如上所述的VLAN均存在,则说明宽带、IPTV、语音业务均下发正常;

中兴OLT:

yl-gl-c300-1#show run interface epon-olt_1/2/1 **查看PON口1/2/1下被注册的光猫的SN Building configuration...

!

interface epon-olt_1/2/1

p2p mode group

onu 3 type ZTE-F460 loid 9995600056C ip-cfg static

onu 4 type ZTE-F460 loid 9995600057C ip-cfg static

onu 5 type ZTE-F460 loid 9995600058C ip-cfg static

onu 6 type ZTE-F460 loid 9995600059C ip-cfg static

yl-gl-c300-1#show run interface epon-onu_1/2/1:3 **查看1/2/1的第3个分光(即ONTID=3的光猫上下发的业务数据情况

Building configuration...

!

interface epon-onu_1/2/1:3

admin enable

property description $onuname$$$

sla-profile ftth-up vport 1

encrypt direction downstream disable vport 1

mac-bind disable

ems-autocfg-request enable

switchport mode hybrid vport 1

service-port 1 vport 1 user-vlan 45 vlan 45 svlan 1021

service-port 2 vport 1 user-vlan 41 vlan 303 svlan 21

service-port 3 vport 1 user-vlan 43 vlan 43 svlan 3021

service-port 4 vport 1 user-vlan 46 vlan 46 svlan 2021

traffic-profile HSI vport 1 sport 2 direction egress

traffic-profile HSI vport 1 sport 2 direction ingress

traffic-profile ITV vport 1 sport 1 direction egress

traffic-profile ITV-1 vport 1 sport 1 direction ingress

traffic-profile ITMS vport 1 sport 4 direction egress

traffic-profile ITMS vport 1 sport 4 direction ingress

traffic-profile VOIP vport 1 sport 3 direction egress

traffic-profile VOIP vport 1 sport 3 direction ingress

ONU设备操作方式和宽带设备基本相同,只是登录时请通过本县OLT的公网网管IP地址登陆即可。

2012年1月30日

自动喷漆机安全操作规程

编号:SM-ZD-48401 自动喷漆机安全操作规程Through the process agreement to achieve a unified action policy for different people, so as to coordinate action, reduce blindness, and make the work orderly. 编制:____________________ 审核:____________________ 批准:____________________ 本文档下载后可任意修改

自动喷漆机安全操作规程 简介:该规程资料适用于公司或组织通过合理化地制定计划,达成上下级或不同的人员之间形成统一的行动方针,明确执行目标,工作内容,执行方式,执行进度,从而使整体计划目标统一,行动协调,过程有条不紊。文档可直接下载或修改,使用时请详细阅读内容。 1.操作人员要求 1.1本机的操作人员必须经专业培训, 熟习机器的结构性能、传动原理和安全生产知识。只有生产部定员的操作人员才有权操作指定机台。 1.2操作人员上班时必须按规定穿戴好防静电工作服。 2.开机前准备 2.1开机前先检查润滑系统油箱中的润滑油是否足够,不足时应及时添加。 2.2开机前先检查往复机传动链条的松紧度,如松紧度不合适应及时调整。 2.3开机前先检查往复机传动链条上是否有漆渣,如有应及时清理。 2.4开机前应先检查气源压力是否正常。 2.5开机前应检查气管及接头是否漏气。

3.工作过程中 3.1 先空机运行2个来回,查看往复机是否存在卡阻现象,查看枪嘴是否堵塞。 3.2 必须在箱体停稳后方可启动自动喷漆机。 3.3 在喷漆过程中,禁止穿越漆房。 3.4 在操作过程中,禁止更改操作系统的参数。 3.5 若出现异常情况时,应按下急停按钮。 3.6 漆房内严禁烟火,严禁吸烟,严禁带火种进入漆房内。 3.7 严禁在漆房内进行清除灰尘和打磨作业。 3.8 严禁在漆房堆放其他杂物。 3.9 一旦发生火情,应及时报警,切断电源,关闭运行设备,关闭临近漆房门,积极组织救火。 3.10 保证漆房周围安全通道畅通。 4.工作完成 4.1 喷漆往复机停靠在固定位置。 4.2 关闭控制面板、主电源、气阀。 4.3 清理往复机链条上的漆渣,加注润滑油。

设备安全操作规程

1、目的 规范作业程序,确保安全生产。 2、适用范围 液压单板剪裁机 3、采用液压单板剪裁机裁木皮时,应遵守本规程。 3.1操作员必须经培训合格后可上岗,非本机操作员不得操作机器。 3.2操作员穿好工作服,严禁戴手套,工作时精神必须高度集中。 3.3开启机床前,先检查机床各部分是否完好,螺丝螺母有无松动现象; 3.4检查工作台面有无杂物,清除与工作物无光的物件; 3.5接通电源,面板指示灯亮,计数器背灯亮,打开“电源”按钮;对刀线照明灯亮; 3.6检查机床光电镜,打开“光电转换”开关,用物体挡住光电镜对射孔,此时,光电开关发出响声,双手启动“刀启动”按钮无作用; 3.7接通电源,调整减压阀,使压力符合机床要求,检查汽缸上下作用是否平稳,否则调整单向节流阀; 3.8打开“电源”按钮,旋转“光电”转换开关,按下“夹紧”扭,压板工作,双手控制两个“刀启动”,刀板工作,剪切后,刀板抬起后,压板自动抬起。工作完毕,关闭“总停”切断电源。 3.9经常检查各部分是否完好,各轴承及润滑点经常润滑,减速机应保持油面线,油雾器供油充分,过滤器经常清洗,以保证进入汽缸及其他元件的压缩空气的质量,认真维护保养,以保持机床使用寿命。

1、目的 规范作业程序,确保安全生产。 2、适用范围 (细)木工带锯机 3、采用带锯机裁板时,应遵守本规程。 3.1操作员必须经培训合格后可上岗,非本机操作员不得操作机器。 3.2操作员穿好工作服,戴好防尘口罩,严禁戴手套,工作时精神必须高度集中。留长发者须将头发盘起。 3.3使用前,检查电源接线是否安装牢固,检查传动皮带的张紧度,主轴制动手柄应在“放松”位置; 3.4清除工作平面及主轴附近的障碍物,当确认以上各项处于完善的情况下即可起动; 3.5操作时,不要穿戴有可能被机床的部件挂扯的衣物及饰品; 3.6在操作过程中,刀具的刃口可能造成人员的伤害,所以要保持上肢和身体的其他部位远离工作区域; 3.7操作过程中产生的碎屑能使地面变滑,应按规定时间进行清理; 3.8更换刀具必须关闭机床的总开关,更换时,应带保护手套; 3.9刀片应保持锋利,不蹦刃、卷刀、弯曲。 4.0严禁送料时猛进猛退,野蛮操作。 编制:朱业辉批准:龚伟杰

中控系统操作手册

中控系统操作手册 前言 会议系统为集成度高且设备集中的一个弱电子系统,为保证此系统能长时间、稳定运行及请用户单位指派专门管理人员及操作人员进行管理和操作,非相关操作人员禁止动用会议室设备(包括各种遥控器),操作人员请严格遵守以下操作流程进行操作,以免误操作而影响整个会议系统的稳定性,甚至导致设备损坏。 详细操作说明如下: 第一部分:3楼外事会议室操作说明 ` (1号和2号外事会议室和新闻发布中心设备操作一样,下面以1号外事会议室为例说 明) 操作流程 第一步:进入设备间,检查调音台推子是否都拉到最底端,如没在最底端,请全部拉到最底端;然后开启系统电源(中控电源、时序控制器电源、强电控制模块电源及其 它电源)用触摸屏开启系统,点击触摸屏起始页,所有设备即可自行按顺序打开。 系统开启后说明:机柜内所有设备电源开启,投影机供电。。。 · 第二步:检查机柜内设备及调音台的电源开关是否打开,若没打开请手动开启。判断开启与否请通过设备指示灯观察。 第三步:根据实际会议内容需求,通过触摸屏依次开启相应的设备、切换相应的信号(详见“、ST-7600C触摸屏的操作”)推起调音台推子。 注:1、触摸屏方向请指向机房,保证最佳的接收信号 第四步:当会议结束,离开操作间时,首先将调音台推至最底端,然后通过触摸屏关闭系统,待时序电源关闭(关闭系统后3分钟)后方可关闭机房,然后离开。 注:1、中控主机及继电器模块无需关闭,请保持常供电状态 ~ 注:1、开启系统前,确保调音台推子拉到最下面,以免造成设备损伤甚至烧毁。 2、音频信号处理设备,如:调音台,均衡器等设备的相关设置已经调试完毕。如无特 殊需求,请勿随意调整原设备的设置,以免影响会议系统的声效。

设备管理软件使用手册

设备经管软件使用手册 一:系统简介 该系统主要用于智能大厦的设备经管,一幢高度智能化大厦的给排水,消防,照明,门禁,防盗报警,电梯,娱乐休闲,停车场,办公,通讯等设备投资巨大,种类繁多,数量庞大,这成千上万个设备分布于信息枢纽大厦主楼和附楼的每一层楼中,对这些设备的经管,需要用科学高效的方式进行经管。 该系统记录设备最基本的资料,如设备名称,类型,编号,位置等。 建立相关的资料库,详细介绍设备性能,用途,使用方法,常见故障及解决办法。 设备相关的资料库详细记载设备厂家,供应商的地址,电话,联系人,原施工单位的地址,电话,联系人,施工图,以及当前备件数等等。 必须建立相关的资料库详细记载当前设备状态,设备经管者。 详细记载每一设备的维修记录,故障分析,结论,解决技术方案,以便提供将来参考。 经管人员可根据具体情况制定维护计划,系统根据计划提醒维护人员实施并填写日志。

系统具有一定程度的智能,如提醒经管者当前哪个设备备件不足,哪个设备没按计划进行维护,能为经管者协调工作。若与BMS,BAS 系统结合,可实现即使短信通知经管者。 二:操作 一)界面简介: 功能键 工程 设备清单 系统 位置 设备经管 子系统 按功能键将进入各具体功能。 按工程栏,系统栏,子系统栏,位置经管栏查寻设备,列在右上的列表里。

二)基本资料录入 1.工程登记,楼宇登记,部门登记。 《到第一个记录。 〈到下一个记 录。 〉到上一个记录。 》到最后记录。 增加:先按增加,接着录入内容, 按确定完成操作。 修改,删除类同。 2.用户注册。

先完成部门的注册以便在这里可以选择。不用填写部门。 操作: 先填写或修改资料,再按增加或修改完成。删除时先选定记录后按删除完成。 以下操作同用户注册。 3.用户权限设置。 先完成用户注册以便方便选择.

常用仪器、设备操作规程流程

常用仪器、设备操作流程、高频电刀操作流程图 打开高频电刀的开关 调整高频电刀功率,符合医嘱要求 粘贴负极板远离切口位置,纵形贴 传递高频电刀笔于手术台 L开始使用高频电刀 .术毕关闭电源 整理用物,分类处理阴道镜操作流程图 打开计算机 点击桌面上的阴道镜操作界面 r~ 开女 -------------- 术毕关闭阴道镜电源开关 I 关闭计算机

、微量注射泵、输液泵的检查流程 检查外观是否清洁,消毒是否规范 Q ___________________________________ 3 -------------------------------------- 检查电源线、配件是否齐全、完整 关机 四、吸引器操作流程 备齐用物至床旁,评估患 j 者,做好解释 一 接通吸引器电源,连接吸引器各管路 --------------- f r 打开电源开关 吸引结束,关闭吸引管 、 ------ --------- 整理用物,使用中吸引瓶 「每天消毒处理 检查外观是否清洁,消毒是否规范 < ___________ _ _____________ J 检查电源线、配件是否齐全,储液瓶及管路连接紧密 y _____________________ _________________ 开机 V ____ 丿 调节负压 五、吸引器的检查流程

六、心电监测操作流程图 < A 备齐用物至床旁(心电监护仪、电极片]5个、棉 .球做,做女接通电作,取得电患者或家属的配合 丿 r ------------------------- 做好皮肤准备—— --------------- ■> 安装电极片,连接心电导联线,屏幕上心电波出现 、. ____________________ _ _____________________________ _ _________________________________ 』 「选择正确类型和尺寸的传感器,安置 「 选择尺寸适 于 病人手指上确认现血完全放度指 数松紧适度缠 —设置病人信息及各项 报警上下限,记录各项参数 七、除颤仪使用操作流程 备齐抢救器械和药品 清洁除颤部位皮肤,电极板均匀涂抹导电胶 y ----------------------------------- 选择同步或非同步电复律,选择合适的能量 充电,嘱旁人让开,准确放置电极板并与皮 <~ 肤接触紧密,同吋按下电极板上的放电键 除颤完毕,观察心电图是否转为窦性心律,如仍为 <室颤,再次充电,间隔一定时间 后重复步骤 o ,安置 八、除颤仪的检查流程 操作完毕,将能量开关回复至 病人,监测心率做心律,并遵医嘱用药

设备操作说明书

废水处理设备 系统操作说明书 苏州万科环境工程有限公司 2014年2月(第一版) 操作和维护该系统时,必须遵守该手册中的操作程序。本手册仅针对本系统,如对其它水处理系统按照本手册操作引起损失,本公司恕不负责。 目录 1 人身安全注意事项.............................................................................................. 1.1电气................................................................................................................ 1.2机械................................................................................................................ 1.3开停机............................................................................................................ 1.4通道............................................................................................................... 1.5安全用具....................................................................................................... 1.6安全检查表................................................................................................... 2 废水处理工艺...................................................................................................... 3处理设备构筑物的运行与控制参数................................................................... 3.1地坑................................................................................................................ 3.2调节池............................................................................................................ 3.3气动隔膜泵.................................................................................................... 3.4管道混合器.................................................................................................... 3.5沉淀池............................................................................................................ 3.6回用水池........................................................................................................ 3.7除油过滤器.................................................................................................... 4加药系统............................................................................................................... 4.1加碱系统....................................................................................................... 4.2混凝剂加药系统........................................................................................... 4.3絮凝剂加药系统........................................................................................... 5. 压滤机系统........................................................................................................ 6. 触摸屏操作说明................................................................................................

喷漆机安全操作规程

喷漆机安全操作规程主要危险源:缠绕、毒物伤害、机械伤害、火灾等 工作前: 1、开机前首先检查开关柜内的电源开关是否已合上,气压达0.6Mpa以上,以下各部分要逐项检查: (1)喷漆机前后进出光电开关是否灵敏、工作正常; (2)传送带位置是否正确,有无跑偏; (3)油漆泵气源是否打开,往复运行有无异常; (4)清洗机的电、气是否已开,洗机水是否加足; (5)回收机、刮刀、布辊位置是否正确,各部分有无漆垢等。 2、各部位检查无误后方可开机,开机时每一项启动应有10秒钟以上间隔,不得一次性全部启动,而且要边看边听,确认是否运转正常。如不能正常运转应做检查后再次启动,再次启动后还不动作时应停机找维修人员修理,排除故障后再开机。 工作中: 1、使用过程中出现故障应查明原因,属气压不足时应待气压上升后再开机,如属电流过大发生热保护,应等复位后再开机。如已两次动作,就不能再启动,应请电工查明原因后方可开机。 2、设备运行中操作者不准离岗,如需临时离开必须向副手交代,有人接岗后方可离开。 3、设备运行中手不得伸入正在运转的部件中,以防出现手被卷入的事故。 4、工作中发生电机过热、运行噪声过大等现象,应停机检查,确认无误后方可继续运行。 工作后: 1、下班时应按顺序关机,不得一次性拉总闸。 2、喷漆机应在停机状态,清洗油漆泵及喷枪及管道。 3、剩余的油漆及稀释剂应加盖密封后在指定地点存放。 4、把垃圾分类后送到垃圾站指定位置。 遇到紧急情况时: 1、应立即停止作业,拉闸断电,再做紧急处理。 (1)如有人中毒立即抬至空气清新处抢救,并同时报告班长或安全员等领导。 (2)如有火情立即呼喊报警,同时扑救初级小火,如果无法控制立即按火警预案疏散,同时报告班长、安全员等领导。

喷涂车间设备管理文件

受控状态:____________ 喷涂车间 设备管理文件 版次/修改状态/ 编制:______________ 审核:______________ 批准:_______________ 发布日期:实施日期:

设备管理文件整理说明 在傅总的关心和指导下,公司工艺小组对喷涂车间在用生产机械设备文件(设备管理办法,设备管理台帐,设备档案资料台帐,设备润滑油管理办法,设备实行包机到人维护卡,设备日常维护保养记录,设备维修记录,设备操作规程等)进行了收集整理,发现喷涂车间的设备管理文件非常少,尤其是关键设备相关规章制度记录表格都没有,根据车间实际情况和公司发展需要,我们整理,新编写“设备管理办法”“设备润滑油管理办法”等文件和记录表格共18种。 在整理编写过程中,我们编写人员下车间了解情况,查询相关法律法规,借鉴其它同行业先进管理文件,结合喷涂车间是实际情况,编写了“喷涂车间设备管理文件”。由于我们的专业水平有限,在收集整理修订编写过程中,还可能存在不足之处,甚至出现错误,请各位领导、师傅在使用中给提出改正意见,便于我们更加完善喷涂车间设备管理文件,指导车间进行科学使用维护维修设备,为设备达到完好,能“长、安、稳、满、优”运行,为保障生产任务完成奠定基础。 公司工艺小组

目录 1、设备管理办法 (3) 2、设备润滑管理办法 (13) 3、喷涂车间设备加油一览表 (19) 4、设备管理台帐 (20) 5、设备档案资料(台帐) (22) 6、设备日常保养操作规范 (23) 7、设备保养(维护)申请单 (24) 8、设备维护计划记录表 (25) 9、设备包机维护责任人卡 (26) 10、喷涂线维护保养记录 (27) 11、抛丸机维护保养记录 (28) 12、空压机维护保养记录 (29) 13、喷涂线安全操作规程 (30) 14、行车安全操作规程 (31) 15、抛丸机安全操作规程 (32) 16、砂轮机安全操作规程 (34) 17、空压机安全操作规程 (35) 18、喷涂工具使用管理办法 (33)

设备安全操作规程大全

设备安全操作规程大全 一、一般安全操作规程 1、本一般安全操作规程使用于公司所有生产设备。 2、只有接受过机器操作培训及安全操作培训并考核合格的人员才能操作机器。 3、非本机台定岗人员未经许可不得操作机器。 4、必须在机器状况良好,所有安全防护罩和防护仪器正常,接地保护良好,并且机器的所有功能正常时,才能使用机器。 5、不得闲置任一安全装置,不得防碍任一安全装置的正常工作。 6、机台操作人员要清楚本机台所有安全防护装置、急停、缓停、的作用。 7、正常情况下的停机操作,不允许用紧急廷臣代替正常停车;不允用打开安全防护装置的方式停车。 8、严禁关闭自动加油装置。 9、当按下紧急停车装置(按钮或拉绳)时,机器立即停止运行,且所有控制装置将不起作用。这些急停装置应定期检查其功能是否完好。 10、开机前应确保机器内没有人,没有人接触机器。 11、机器运行时,禁止将手、脚或身体的任何部位伸进机器内或靠近运行的机

器部件。 12、机器运行时操作人员不得离开机器。 13、机器运行时,严禁攀上机器。 14、禁止隔着机器传替工具。严禁在机器上放置工具及其它物品,以免进入机器,造成功能事故。 15、保持机器周围的工作区域和机身干净整洁。地面、平台和机器的内部需定期清洁。油脂、机油以及其它粘滑物等危险品应及时清除,防止人员滑倒。 16、进入机器内操作前,必须锁死急停按钮,必要时须停电并锁死。 17、非专业人员不准随意打开电气接线盒、动力柜、配电柜和控制柜,必要时应要求专业人员做指导。 18、有的机台可能会用到一些溶剂做清洗用,无论使用任何溶剂,应注意对皮肤的保护,应用如手套等保护物品,且事后要立即将剩余的溶剂放到指定的溶剂存放的地点,以免在机器工作时发生意外。 19、任何溶剂不得放在机器的发热部位或接近电器原件。 20、发现机器出现故障应立即停机并向当班维修人员汇报,同时通知其它可能使用此机器的人员。 22、发生事故时,应立即向有关部门领导汇报并保护好现场,同时催当时情况写出真实的书面报告。

设备管理系统概要设计说明书

设备管理系统概要设计说明书 1

1引言............................................................................... 错误!未定义书签。 1.1编写目的............................................................. 错误!未定义书签。 1.2背景..................................................................... 错误!未定义书签。 1.3定义..................................................................... 错误!未定义书签。 1.4参考资料............................................................. 错误!未定义书签。2总体设计....................................................................... 错误!未定义书签。 2.1需求规定............................................................. 错误!未定义书签。 2.2运行环境............................................................. 错误!未定义书签。 2.3基本设计概念和处理流程................................. 错误!未定义书签。 2.4结构..................................................................... 错误!未定义书签。 2.5功能器求与程序的关系..................................... 错误!未定义书签。 2.6人工处理过程..................................................... 错误!未定义书签。 2.7尚未问决的问题................................................. 错误!未定义书签。3接口设计....................................................................... 错误!未定义书签。 3.1用户接口............................................................. 错误!未定义书签。 3.2外部接口............................................................. 错误!未定义书签。 3.3内部接口............................................................. 错误!未定义书签。4运行设计....................................................................... 错误!未定义书签。 4.1运行模块组合..................................................... 错误!未定义书签。 4.2运行控制............................................................. 错误!未定义书签。 4.3运行时间............................................................. 错误!未定义书签。 2

起点设备管理系统_起点设备管理软件~使用手册

设备管理系统 ——C/S简介 目录 一系统简介 (3) 二系统流程 (3) 三首次使用系统 (4) 1.基本参数设置: (4) 2.权限设置 (4) 3.系统初始化 (5) 4.现有设备信息录入或导入 (5) 5.正式启用 (5) 四系统功能 (6) 1.台帐管理 (6) 1)设备台帐 (7) 2)配件台帐 (10) 3)维修登记 (11) 4)设备调拨登记 (12) 5)配件调动登记 (13) 6)销账登记 (14) 7)设备折旧 (14) 8)条码打印 (15) 9)设备导入 (16) 10)配件导入 (16) 11)设备预警 (16) 2.设备盘点 (17) 1)下载数据 (17) 2)设备盘点 (18) 3)盘点查询 (19) 3.辅助管理 (20) 1)人员管理 (20) 2)供应商管理 (20) 3)维修站管理 (20) 4)合同管理 (20) 4.查询打印 (21) 5.统计报表 (22) 6.参数设置 (23) 1.组织结构管理 (23) 2.设备种类设置 (24)

3.配件种类设置 (25) 4.故障类型设置 (26) 5.配置参数设置 (26) 6.自定义项设置 (27) 7.系统管理 (27) 1)基础字典设置 (27) 2)系统参数设置 (28) 3)组维护 (29) 4)组权限设置 (29) 5)操作员设置 (30) 6)修改操作员密码 (31) 7)系统初始化 (31) 8)系统数据库备份(该功能只存在于单机版) (32) 9)系统操作日志 (32) 10)导出数据 (33) 11)导入数据 (34) 8.系统 (34) 五附件 (35)

设备管理系统用户使用手册

设备管理系统用户手册 目录 系统简介 (2) 系统流程 (3) 系统功能 (4) 台帐管理 (4) 设备台帐 (4) 设备折旧 (6) 条码打印 (6) 设备导入 (7) 设备预警 (8) 辅助管理 (8) 人员管理 (8) 供应商管理 (8) 维修站管理 (8) 合同管理 (8) 查询打印 (9) 统计报表 (10) 参数设置 (10) 组织结构管理 (10) 设备种类设置 (11) 故障类型设置 (12) 配置参数设置 (12) 自定义项设置 (12) 系统管理 (13) 基础字典设置 (13) 系统参数设置 (13) 组维护 (13) 组权限设置 (14) 操作员设置 (15) 系统初始化 (15) 导出数据 (16) 导入数据 (16) 系统 (16) 在线升级 (16)

起点智能设备管理系统主要适用于资产密集型企业对高价值固定资产的维护、保养、跟踪等信息管理。它以提高资产可利用率、降低企业运行维护成本为目标,以优化企业维修资源为核心,通过信息化手段,合理安排维修计划及相关资源与活动,从而提高企业的经济效益和企业的市场竞争力。随着计算机在各类企业中的应用范围不断扩大,各企业的设备不仅在速度、数量、品种增长快,而且设备的移动、升级和故障维修也非常快,使技术部门对设备资产管理的难度越来越大,传统的手工制表、人工登记的办法,已不能及时反映每台设备的真实情况,迫切需要建立一个企业的资产管理系统。 起点设备管理系统,针对企业内部使用的大量的设备不易管理而精心设计的。主要有六个功能模块:设备登录、设备查询、条码打印、人员管理、设备管理、系统管理。它可以对设备进行全面的管理,管理项目包括:记录这一设备的各项特性指标以及使用部门、购买日期等基本信息和它的维修、升级等情况;设置任意条件对设备各类信息进行查询;对保修期做出预警等。人员管理登记人员情况,对维护、维修设备的情况做出统计。

大型设备安全操作规程(正式)

编订:__________________ 单位:__________________ 时间:__________________ 大型设备安全操作规程 (正式) Standardize The Management Mechanism To Make The Personnel In The Organization Operate According To The Established Standards And Reach The Expected Level. Word格式 / 完整 / 可编辑

文件编号:KG-AO-9507-73 大型设备安全操作规程(正式) 使用备注:本文档可用在日常工作场景,通过对管理机制、管理原则、管理方法以及管理机构进行设置固定的规范,从而使得组织内人员按照既定标准、规范的要求进行操作,使日常工作或活动达到预期的水平。下载后就可自由编辑。 一、6640 原子吸收光谱仪 1、开机前,必须检查仪器各旋钮、开关是否处于正常位置。 2、接通总电源后,必须待稳压器输出电压稳定在220V后才能开启主机电源。通电后如发现异常情况或声音,立即断电,请维修人员检查,未经同意不准随意拆卸仪器。 3、点火时,先开抽风,并检查是否有水封、各气路系统有无漏气,发现问题及时处理。熄火时,先关乙炔后关空气。 4、安装或取下空心阴极灯时,应谨慎小心,电流不得超过额定电流的2/3,不得用手触摸石英窗、光路中透镜。 5、未经同意不得随意打开光路系统的暗箱。仪器

经过大修后必须由专业人员校正后才能投入使用。 6、仪器室严禁吸烟。 二、ARL 9400 1、不得擅自改动分析程序,不得在线机上使用私人磁盘、光盘及上网浏览网上邻居等。严禁学徒工独立操作。 2、每班不少于两次点检仪器设备状态(包括内、外冷却系统,真空泵油等),并详细记录。若有异常情况,及时通知技术和维修人员,并详细记录事故原因及处理过程。 3、操作间的温度必须控制在22±2℃,湿度必须控制在40%~70%。 4、遇突然停电时,迅速断开配电盘的开关,将所有仪器设备的开关置于OFF位置。 5、开启光管时,应逐渐对光管加载电流、电压;尤其是对长时间关闭的光管,应于1小时内逐渐加载到常规工作功率。 6、仪器大修后,必须经专业人员校正才能投入使

设备操作手册

設備操作手冊......步進式指導 安全 設備概觀 人機介面 三色燈 開機與登入 產品換線 印刷產品 耗材補充 物品更換 登出與關機 錯誤訊息

警告與小心 為了確保印刷機操作狀況在任何時間均保持安全,所有職員必須廣泛地遵守並接受除在手冊描述之特別安全注意事項外之安全規範. 警告標示引起作業員與保養員對可造成死亡,重傷或病症的可能危險的注意.這些危險不是設備固有就是在設備操作時產生出來的.在機器上使用的警告標籤的範例展示於另一邊的表格內. 底下展示的結合警告和小心預防的標籤,貼於機台上意味著使用者嘗試在設備上執行此作業前應先參閱技術參考手冊內相關章節內容. 小心標示警告職員隨著偏離描述步驟所可能引發的人或料可能的損害.小心標示並不意味對職員的危險. 一個小心標示的例子如下: 小心 攝影機損毀..不要留下任何未用治具於升降平台的後軌道後方區域.如有任何物體留在升降平台的PC板印刷區域外,當平台上升至印刷高度時,它將可能與攝影機相撞.安全 警告: 驚嘆號 應用於未被特殊警示所涵蓋的一切危險的一般警示. 警告: 切割物 在警示標籤附近存在銳利邊緣傷害的危險.當在指定 區域工作時需特別小心. 警告: 刺激物 存在會立即產生發炎的物質,並會重複或延長與黏膜 或皮膚的接觸. 警告: 易燃物 存在易燃物質,應遠離熱,燃燒源與靜電放電,使用於通 風良好區域. 警告: 移動物 在警示標籤附近存在移動物件,這些物件有能力造成 傷害.設備外蓋不可移開. 警告: 輻射物 在標籤附近存在因雷射光造成眼睛傷害的危險.不要 直視光源或物體表面之直接反射光. 警告: 受壓物 高壓存在並可能造成傷害.不要企圖直接開啟系統至 大氣下. 警告: 電力危險 高電壓存在並可能造成傷害或死亡.不要從設備外罩 移除保護蓋或不顧保護裝置. 警告定義

项目管理系统操作手册

泰格林纸集团 怀化制浆工程项目管理系统(简称:HH-CPMS) 用户操作手册 [系统管理员] 文档 TEMCO-DOC-PROC-PUM-001 编号 修订版 状 态 2006-11-28 日 期 当前 版本 前一 版本

目录

1系统特点3 系统简介 (3) 系统功能结构 (3) 界面布局说明 (4) 系统特色描述 (6) 2通用操作7 通用控件说明 (7) 通用功能操作 (8) 通用按钮 (8) 日期选择 (9) 通用页面说明 (9) 树型编辑页面 (9) 树型选择页面 (12) 列表选择页面 (13) 3系统管理员操作说明15 系统安装 (15) 系统环境 (15) 系统软件安装 (15) 应用软件安装 (16) 系统支撑 (17) 组织结构维护 (17) 管理人员维护 (18) 系统用户管理 (19) 部门业务管理 (19) 系统角色维护 (20) 角色授权管理 (21) 管理流程定义 (23) 系统维护 (25) 系统备份 (25) 运行环境维护 (25) 安全防范措施 (26) 系统维护建议 (28) 日常运行记录 (30)

1系统特点 1.1系统简介 本软件产品的名称是:湖南泰格林纸集团怀化制浆工程项目管理系统(简称:HH-CPMS)。该软件项目客户为湖南泰格林纸集团,管理对象为泰格林纸集团怀化四十万吨制浆项目及其它相关的项目。 项目管理系统的范围与外部处理流程是项目生命周期在信息管理中的逻辑展开,而其内部结构与处理流程是项目管理职能在信息处理过程中的客观反映。 怀化项目指挥部(怀化项目公司)在项目建设期间,是属于典型的总指挥长负责制的项目型组织,该项目公司的工作都是以项目为中心来展开,按照项目管理业务及业务流程的特征,公司设立了负责工程管理工作的工程管理部(下属7个项目分部);负责资金与支付控制的财务部;负责工程设备和材料采购、仓储、供应的设备材料部;负责前期工作、设计、技术资料、生产筹备和人员培训的生产技术部;负责投资控制、人力资源、劳资、工作绩效考核、日常办公事务的综合管理部等五个部门。 1.2系统功能结构 本系统处理怀化制浆工程项目的相关业务数据、根据对业务的分析和用户的需求,我们对系统划分为以下17个功能模块: 投资计划管理; 进度计划管理; 质量安全管理; 前期工作管理; 项目设计管理 项目施工管理;

智能化系统设备操作手册范本

智能化系统设备操 作手册

目录 1 编制说明 ............................................................ 错误!未定义书签。 2 安保机房建设概况............................................. 错误!未定义书签。 2.1 操作区设备及功能............................................. 错误!未定义书签。 2.2 核心区设备及功能............................................. 错误!未定义书签。 3 各子系统的操作流程说明 ................................. 错误!未定义书签。 3.1 视频监控系统操作............................................. 错误!未定义书签。 3.1.1 使用监控控制键盘切换分频显示及液晶拼接屏画面的操作... 错误!未定义书签。 3.1.2 使用管理电脑控制拼接屏图像显示与切换的操作错误!未定义书签。 3.1.3 视频监控录像的回放操作 ............................. 错误!未定义书签。 3.1.3.1 本地回放操作 ........................................... 错误!未定义书签。 3.1.3.2 远程回放操作 ........................................... 错误!未定义书签。 3.2 防盗报警系统操作............................................. 错误!未定义书签。 3.2.1 使用报警键盘实现布防、撤防和旁路的操作错误!未定义书签。 3.2.2 利用报警键盘实现联动报警的设置.............. 错误!未定义书签。 3.3 门禁系统操作 .................................................... 错误!未定义书签。 3.3.1 金库卷帘门的操作 ......................................... 错误!未定义书签。 3.3.2 金库区与办公区通道侧门操作 ..................... 错误!未定义书签。

喷涂设备保养与维护操作

武汉星光达实业有限公司 喷涂设施与设备的保养与维护操作规程 文件编号XQW-JS-089 文件版本A/0 生效日期2013年09月20日页码1/6 一、目的 为了更好的保护喷涂设施及设备,保证生产的正常进行。 二、范围 适用于喷涂生产线及周边设备(关键设备为主)。 三、责任 生产部全体员工。 四、工作程序 喷油房的保养明细 4.1喷油房的抽风系统保养: 4.1.1风机的叶轮清洁;每月设备定期保养日,设备管理员用扳手把紧固螺钉松开,喷涂作业员用刮刀铲除叶轮上的油漆后,叶轮上打上黄油;设备再安装 好叶轮,并锁紧紧固螺钉。(每隔一月一次) 4.1.2挡风板的清洁:每周六设备保养时,设备的使用者取下挡风板,用刮刀刮去板上的油漆,用水冲洗干净,晾干后打上黄油。 4.1.3喷淋管路,喷嘴的清洁;每周六设备保养时,设备的使用者取下喷嘴,和设备管理员拆下水管,用小铁棒斗松管内的油漆后,用水清洗干净管内的,喷 嘴内的油漆渣滓,设备清洁完毕后,安装好水管,喷嘴。喷嘴的开口在一个 平面。 4.1.4抽水机的清洁与保养:每月设备保养日,喷涂放完喷油柜里的水,设备管理员松下紧固螺钉,取下水泵;清洗干净叶轮上的油漆渣滓及水道壁的油漆渣 滓后,安装好紧固螺钉。 4.1.5水濂柜内壁清洁:设备的使用者把水管接在供水管上,打开水开关用水从往下冲淋。 4.2鲜风系统的维护和保养:(半月清洗一次) 4.2.1喷涂停线,喷涂车间安排人员取下高效过滤棉,过滤网,把高效过滤棉翻出,放进水里漂洗,洗干净后挂起晾干。 注意:清洗的过程中,不要拧,扭过滤棉和过滤网,取过滤网的先后顺序:按 先高效后低效,即先内后外;清洗好后安装顺序刚好相反,即先低效后高 效,即先外后内。 4.2.2喷涂安排人员用清水打湿干净的擦拭布,擦拭干净框边的灰尘。 4.2.3喷涂把清洗干净并晾干的过滤棉和过滤网安装好,框与框之间用过滤网压紧。 4.2.4蒸汽管的保养:生产部用高温棉把外漏的蒸汽通道包裹,对生锈严重管道予以更换,对泡在水里的或被水经常淋的蒸汽管道予以改道,并安装好控制开 关,标识蒸汽通道,方向及警示语,汇总图并悬挂在安全栏。 4.3加热室及烘炉的保养: 4.3.1喷涂派人把加热室的过滤棉取下,更换成新的高温过滤棉;生产部点检加热

设备安全操作规程--上墙

为保证安全生产,全厂职工除遵守本岗位工种安全技术操作规程外,还必须遵守下列总则: 1. 认真执行国家有关劳动安全法规、规定及本厂各项安全生产规章制度。 2. 新入厂工、调换工种的工人及来厂实习、代培和临时参加生产的人员,必须经过安全教育和操作技术培训,经考试合格后在师傅的指导下进行操作。 3. 电气、起重、焊接、锅炉、压力容器、车辆驾驶、叉车工等特种作业人员,必须持证操作。 4. 操作工必须熟悉产品性能、工艺规程及设备操作要求,会正确处理生产过程中出现的故障。 5.操作前必须按规定正确穿戴好个人的防护用品。披肩发、长辫必须罩人工作帽内。进入有可能发生物体打击的场所必须戴安全帽;有可能被传动机械绞辗伤害的作业不准戴手套;不准穿戴围巾、围裙,脖子上不准佩带装饰品;生产作业场所不准赤膊;不准穿高跟鞋、拖鞋(除规定外)。 6.工作时应集中精力、坚守岗位,不准做与本职工作无关的事。上班前不准饮酒。 7.开动非本工种以外设备时,须经有关领导批准。 8.操作对人体有发生伤害危险的机械设备时,应检查安全防护装置是否齐全可靠,否则不准进行操作。 9.不准随意拆卸、挪动各种安全防护装置,安全信号装置,防护围栏、警戒标志等。 10. 检修机械、电气设备时,必须切断电源,挂上警示牌。合闸前要仔细检查,确认无人检修后方准合闸。 11. 操作中使用的行灯及局部照明,其电压不得超过36V,金属容器内和潮湿场所作业不得超过12V。 12.生产场所应保持整齐、清洁、原材料、半成品及成品要堆放合理,安全通道畅通,废料应及时清除。 13. 高空作业人员必须系好安全带,登高用的扶梯必须坚实牢固,符合安全技术要求,并采取可靠的防滑措施。 14. 非电气作业人员严禁装修电器设备和线路。 15. 易燃、易爆等生产作业场所,严禁烟火及明火作业。 16. 禁止在产生有毒有害物质作业场所内进餐、饮水,工作时要戴好防毒口罩或其它防护用品。

相关主题
文本预览
相关文档 最新文档