溶出度检查法美国药典USP-711

<711> DISSOLUTION 溶出度 (USP39-NF34 Page 540) General chapter Dissolution <711> is being harmonized with the corresponding texts of the European Pharmacopoeia and/or the Japanese Pharmacopoeia. These pharmacopeias have undertaken to not make any unilateral change to this harmonized chapter. 通则<711>溶出度与欧盟药典和日本药典中的相应部分相统一。这三部药典承诺不做单方面的修改。 Portions of the present general chapter text that are national USP text, and therefore not part of the harmonized text, are marked with symbols to specify this fact. 本章中的部分文字为本国USP内容,并没有与其他药典统一。此部分以()标注。 This test is provided to determine compliance with the dissolution requirements where stated in the individual monograph for dosage forms administered orally. In this general chapter, a dosage unit is defined as 1 tablet or 1 capsule or the amount specified. Of the types of apparatus designs described herein, use the one specified in the individual monograph. Where the label states that an article is enteric coated and a dissolution or disintegration test does not specifically state that it is to be applied to delayed-release articles and is included in the individual monograph, the procedure and interpretation given for Delayed-Release Dosage Forms are applied, unless otherwise specified in the individual monograph. 本测试用于检测药品口服制剂的溶出度是否符合各论中的规定。本章中,除另有规定外,单位制剂定义为1片或1粒胶囊。对于本章中所述多种仪器,使用各论中规定的种类。除各论中另有规定外,如果检品是肠溶衣片且各论中的溶出度或崩解时限检查项下没有特别指出适用迟释剂的,使用本章中适用于迟释剂的流程和解释。 FOR DOSAGE FORMS CONTAINING OR COATED WITH GELATIN涂有或包含明胶的剂型 If the dosage form containing gelatin does not meet the criteria in the appropriate Acceptance Table (see Interpretation, Immediate-Release Dosage Forms, Extended-Release Dosage Forms, or Delayed-Release Dosage Forms) because of evidence of the presence of cross-linking, the dissolution procedure should be repeated with the addition of enzymes to the medium, as described below, and the dissolution results should be evaluated starting at the first stage of the appropriate Acceptance Table. It is not necessary to continue testing through the last stage (up to 24 units) when criteria are not met during the first stage testing, and evidence of cross-linking is observed. 如果剂型中含有明胶,其不符合验收表中的标准(见判断,速释制剂,延释制剂,缓释制剂),因为存在明胶交联结合作用,它的溶解过程与外加的媒介酶是重复的,见下面的描述,并且溶解结果可以通过适当的验收表的开始的第一阶段标准进行评估。如果溶出结果不满足第一阶段的测试标准,那么就没有必要继续测试到最后阶段,并且也证明了明胶交联结合作用的存在。

色谱柱的种类与评价

色谱柱的种类与评价 一般地说,根据样品的性质决定采用何种液相色谱方法,然后再选择不同类型的柱。即不同类型的柱则代表了不同的色谱方法。 不同种类色谱柱的差异在于柱结构、柱填料和柱尺寸的不同。 色谱柱有不同的尺寸(长度和内径),分制备型、常规分析型和微型。不同类型柱的硬件也不同,(包括接头、柱管等方面),还有径向加压柱和夹套加热柱等。 不同液相色谱法的尺寸根据需要可以选取,普通分析3~30cm 长,内径4~8mm。常用20cm长、4.6mm内径的柱。制备型柱内径一般为8mm、25cm长。微型柱内径l~3mm,长10~20cm。不同的填料分析的效果可能不同,这是因为生产过程不同所致。同一厂商生产的同种填料因批号不同也会有差异,这种差异可能从基质就开始(表面积、杂质、特殊处理),还有键合的化学物质(一氯或三氯硅烷反应剂),不同厂家生产的填料还会因专利技术(预处理、键合过程、填装技术)等不同而呈现较大差异。由于种种差异、仅能假设同一批号的柱有基本相同的性质。

多数柱填料基质采用多孔硅胶微粒,通常有球形和无定形两种,具有不同的粒度、孔径和表面积。多孔聚合物微粒也适用于反相色谱。聚合物柱的流动相范围广,流动相pH值可在1至13之间。而硅胶基质pH仅能在2.5和7之间。显然,聚合物柱要好一些,但目前仍是以硅胶基质的柱为主。原则上,聚合物柱可以克服硅胶基质柱的某些不足,但需要大量的实验来证实,要进一步考查聚合物基质填料的全面优越性。 在实际工作中,选择性能良好的色谱柱可得到好的结果,首先要注意柱径、长度、填料种类和填料粒度。 评价色谱柱的好坏不仅只是N数,还应考虑组分在柱上的保留、键合相表面的物性、柱压降以及峰不对称因子As等。每一根新色谱柱都应标出详细参数,主要内容包括公司名称、柱名称(商标)、柱填料、尺寸。附一张标准参考色谱图,并标出色谱条件、样品名称、流动相组成、流速、柱温、进样体积、检测器、峰的保留时间及峰名称等。评价一根色谱柱的主要指标是:①塔板数N值;②峰不对称因子As;③柱压降;④键合相浓度。 此文章由广州深华生物技术有限公司编辑修改。

气相色谱柱知识详解

气相色谱柱知识详解 第一节气相色谱柱的类型 气相色谱法(gas chromatography, 简称GC)亦称气体色谱法,气相层析法。其核心即为色谱柱。 气相色谱柱有多种类型。从不同的角度出发,可按色谱柱的材料、形状、柱内径的大小和长度、固定液的化学性能等进行分类。色谱柱使用的材料通常有玻璃、石英玻璃、不锈钢和聚四氟乙烯等,根据所使用的材质分别称之为玻璃柱、石英玻璃柱、不锈钢柱和聚四氟乙烯管柱等。在毛细管色谱中目前普遍使用的是玻璃和石英玻璃柱,后者应用范围最广。对于填充柱色谱, 大多数情况下使用不锈钢柱,其形状有U型的和螺旋型的,使用U 型柱时柱效较高。按照色谱柱内径的大小和长度,又可分为填充柱和毛细管柱。前者的内径在24mm,长度为110m左右;后者内径在0.20.5mm,长度一般在25100m。在满足分离度的情况下,为提高分离速度,现在也有人使用高柱效、薄液膜的10m短柱。 根据固定液的化学性能,色谱柱可分为非极性、极性与手性色谱分离柱等。固定液的种类繁多,极性各不相同。色谱柱对混合样品的分离能力,往往取决于固定液的极性。常用的固定液有烃类、聚硅氧烷类、醇类、醚类、酯类以及腈和腈醚类等。新近发展的手性色谱柱使用的是手性固定液,主要有手性氨基酸衍生物、手性金属配合物、冠醚、杯芳烃和环糊精衍生物等。其中以环糊精及其衍生物为色谱固定液的手性色谱柱,用于分离各种对映体十分有效,是近年来发展极为迅速且应用前景相当广阔的一种手性色谱柱。 在进行气相色谱分析时,色谱柱的选择是至关重要的。不仅要考虑被测组分的性质,实验条件例如柱温、柱压的高低,还应注意和检测器的性能相匹配。有关内容我们将在以后章节中加以详细讨论。 第二节填充气相色谱柱 填充气相色谱柱通常简称填充柱,在实际分析工作中的应用非常普遍。据资料统计,日常色谱分析工作大约有80%是采用填充柱完成的。填充柱在分离效能和分析速度方面比毛细管柱差,但填充柱的制备方法比较简单,定量分析的准确度较高,特别是在某些分析领域(例如气体分析、痕量水分析)具有独特用途。从发展上看,虽然毛细管柱有逐步取代填充柱的趋势(例如已有一些日常分析使用PLOT柱代替过去常用的气固色谱填充柱),但至少在目前一段时期内,填充柱在日常分析中仍是一种十分有价值的分析分离手段。 填充柱主要有气固色谱柱和气液色谱填充柱两种类型。在色谱柱中关键的部分是固定相。在本节我们将首先介绍柱管的选择及其处理方法,然后再分别重点讨论气固色谱柱和气液色谱填充柱有关固定相的内容。

色谱柱的分类及特点

3-1 柱的结构 1、堵棒(或导管) 2、接头 3、接头 4、密封圈 5、螺帽 6、柱密封圈 7、柱管 8、柱填料9 10、过滤片 3-2 柱的分类: 根据所有的担体材料分为三种: a.硅胶型:机械强度高,易制成小颗粒,理论塔板数高。 b.聚全物型:在广泛的PH值范围内稳定 c.羟基磷灰石型:对蛋白质等生物高分子样品有特殊的选择性。 根据分离方式分类: a.硅胶型

1)正相:SIL--磷脂、NH --糖、维生素E,CN--甾类激素。 2)反相:ODS(C18)、(C8 CN TMS Pheny1)低分子量化全物。 3)离子交换: WAX(弱碱阴离子交换)--核苷酸、蛋白质 WCX(弱酸阳离子交换)--蛋白质 SAX(强碱阴离子交换)--核苷酸 SCX(强酸阳离子交换)--儿茶酚胶 4)凝胶过滤: Diol--蛋白质GF--

蛋白质 b.聚合物型: 1)反相:ODP--50--肽,蛋白质,低分化合物。 2)离子交换:ISC--氨基酸,胍类化合物,ISA--糖,IC--无机离子,PA--蛋白质,ES--蛋白质。 3)配位交换:SCR(磺化聚苯乙烯)--糖。 4)离子排阻:SCR-101H 102H --有机酸 5)凝胶过滤:ION--多糖GS--水溶性分子 6)凝胶渗透色谱(GPC):GPD

--合成分子、橡胶。 7)羟基磷灰石型:HPC--蛋白质、核苷酸 按尺寸分类: 1.制备:30mm 50mm 内径,半制备:20mm内径。 2.分析:标准型柱:4_8mm内径。 快速色谱柱:3mm内径、5cm长、4.6mm内径。 小孔径柱:2.5mm内径,微孔径柱1mm内径。 3-3柱的技术指标 *耐压:不小于40Mpa。 *渗透性:反相--流动相甲醇1ml/min,压力3Mpa。

气相色谱毛细管柱使用知识

气相色谱毛细管柱使用知识 气相色谱毛细管柱因其高分离能力、高灵敏度、高分析速度等独特优点而得到迅速发展。随着弹性石英交联毛细管柱技术的日益成熟和性能的不断完善,已成为分离复杂多组分混合物、及多项目分析的主要手段,在各领域应用中大有取代填充柱的趋势。现在新型气相色谱仪、气相色谱-质谱联用仪基本上都是采用毛细管色谱柱进行分离分析。但是,毛细管色谱柱柱内径较小,固定液的膜薄,用于食品中残留物分析时,若使用不当,色谱柱性能很快就会下降。 毛细管柱只能安装在配有专用毛细管柱连接装置的气相色谱仪上。现在购买仪器时最常规的配置是配毛细管分流/不分流进样口。 毛细管色谱柱的类型 毛细管色谱柱的类型有很多种,但目前最常用和商品化的,是开口熔融石英交联毛细管色谱柱。下面介绍此类毛细管色谱柱的性能特点。 一、熔融石英毛细管柱 (1) 熔融石英毛细管柱材料 现在市售商品化的气相色谱用毛细管柱几乎都是由熔融石英制作的,简称石英毛细管柱。制作毛细管柱用的石英纯度非常高,几乎无其它杂质。它具有熔点高(近2000℃)、热膨胀系数低、化学稳定性好和抗张强度高等特点,是制备毛细管柱的理想材料。

毛细管柱内壁存在有许多具有吸附活性的基团,这些基团的存在直接影响固定相涂渍效果,所以,在涂渍固定相之前,柱表面必须经过适当预处理,以期得到较高的柱效和对称的色谱图形。 (2) 石英毛细管柱的聚酰亚胺外涂层 石英毛细管柱很脆,只有在毛细管柱外涂一层聚酰亚胺保护材料后才具有很好的弹性,在使用这样的色谱柱时应十分小心,避免将聚酰亚胺涂层损坏,导致毛细管柱易折断。 通常商品毛细管柱出厂时都固定在一个金属丝制作的柱架上,柱架的直径与毛细管柱的直径成正比,即:毛细管柱的直径越大,固定架的直径也就越大。对于0.53mm 内径的毛细管柱,过度弯曲很容易折断,使用安装时要格外小心。 石英毛细管柱外涂层还有采用镀铝膜的,这类柱子适用于高温分析。但日常分析工作中使用较少,这里不作详细介绍。 二、液体固定相 将固定相均匀涂渍在毛细管柱的内壁,制成壁涂型毛细管柱,这类毛细管柱属非交联型毛细管柱。现在只有少部分的非交联固定相的毛细管柱在使用。非交联毛细管柱的固定相容易流失,不能清洗,因此使用寿命较短,但制作成本较低,涂渍相对较容易,往往在毛细管柱研制前期过程中采用此方法。在使用这类毛细管色谱柱时,应注意使用温度不要超过液体固定相的最高使用温度。建议不要在气相色谱-质谱联用仪上使用。 三、交联固定相 现在市售的商品毛细管色谱柱基本上均采用交联技术,将固定相与石英表面结合起来,在毛细管柱表面形成一层不溶的类似橡胶的非常稳固的涂层。被交联的固定相与涂渍的固定相相比,流失低,抗污染,热稳定性好,使用寿命长。

美国药典规定色谱柱类型

L1:十八烷基键合多孔硅胶或无机氧化物微粒固定相,简称ODS柱 L2:30~50mm表面多孔薄壳型键合十八烷基固定相,简称C18柱 L3:多孔硅胶微粒,即一般的硅胶柱 L4:30~50mm表面多孔薄壳型硅胶柱 L5:30~50mm表面多孔薄壳型氧化铝柱 L6:30~50mm实心微球表面包覆磺化碳氟聚合物,强阳离子交换柱 L7:全多孔硅胶微粒键合C8官能团固定相,简称C8柱 L8:全多孔硅胶微粒键合非交联NH2固定相,简称NH2柱 L9:强酸性阳离子交换基团键合全多孔不规则形硅胶固定相,即SCX柱 L10:多孔硅胶微球键合氰基固定相(CN),简称CN柱 L11:键合苯基多孔硅胶微球固定相,简称苯基柱 L12:无孔微球键合季胺功能团的强阴离子交换柱 L13:三乙基硅烷化学键合全多孔硅胶微球固定相(C1),简称C1柱 L14:10mm硅胶化学键合强碱性季铵盐阴离子交换固定相,简称SAX柱 L15:已基硅烷化学键合全多孔硅胶微球固定相,简称C6柱 L16:二甲基硅烷化学键合全多孔硅胶微粒固定相C2柱 L17:氢型磺化交联苯乙烯-二乙烯基苯共聚物,强阳离子交换柱 L18:3~10mm全多孔硅胶化学键合胺基(NH2)和氰基(CN)柱 L19:钙型磺化交联苯乙烯-二乙烯基苯共聚物,强阳离子交换柱 L20:二羟基丙烷基化学键合多孔硅胶微球固定相(Diol),简称二醇基柱 L21:刚性苯乙烯-二乙烯基苯共聚物微球填料柱 L22:带有磺酸基团的多孔苯乙烯阳离子交换柱 L23:带有季胺基团的聚甲基丙烯酸甲酯或聚丙烯酸酯多孔离子交换柱 L24:表面含有大量羟基的半刚性聚乙烯醇亲水凝胶柱 L25:聚甲基丙烯酸酯树脂交联羟基醚(表面含有残余羧基功能团)树脂。能分离分子量100~5000MW 范围的水溶性中性、阳离子型及阴离子型聚合物(用聚氧乙烯测定)的固定相 L26:丁基硅烷化学键合全多孔硅胶微球固定相,即C4柱 L27:30~50mm的全多孔硅胶微粒 L28:多功能载体,100?的高纯硅胶加以氨基键合以及C8反相键合的官能团 L29:氧化铝,反相键合,含碳量低,氧化铝基聚丁二稀小球,5mm,孔径80? L30:全多孔硅胶键合乙基硅烷固定相 L31:季胺基改性孔径2000?的交联苯乙烯和二乙烯基苯(55%)强阴离子交换树脂 L32: L-脯氨酸铜配合物共价键合于不规则形硅胶微粒的配位体的交换手性色谱填料 L33:能够分离分子量4000~40000MW范围蛋白质分子的球形硅胶固定相, pH稳定性好 L34:铅型磺化交联苯乙烯-二乙烯基苯共聚物强阳离子交换树脂,9mm球形 L35:锆稳定的硅胶微球键合二醇基亲水分子单层固定相,孔径150? L36:5mm胺丙基硅胶键合L-苯基氨基乙酸-3,5二硝基苯甲酰 L37:适合分离分子量2000~40000MW的聚甲基丙烯酸酯凝胶 L38:水溶性甲基丙烯酸酯基质SEC色谱柱 L39:亲水全多孔聚羟基甲基丙烯酸酯色谱柱 L40:Tris 3,5-二甲基苯基氨基甲酸酯纤维素涂覆多孔硅胶微球 L41:球形硅胶表面固定α1酸糖蛋白固定相 L42: C8和C18硅烷化学键合多孔硅胶固定相 L43:硅胶微球键合五氟代苯基固定相

气相色谱柱的选择

气相色谱柱的选择 当面对一个未知物时,先试用现有GC柱,如果该柱分离不理想,根据你对样品的了解,基本原则是分析物与固定相有相似化学性质时才会相互作用。这说明对样品越了解,越容易找到合适的固定相。非极性分子——通常仅由C和H组成并且无偶极矩,直联(正烷)是常见的非极性化合物的例子。极性分子——主要由C和H组成同时也有其他原子,如:N、O、P、S或卤素。样品包括有醇类、胺类、硫醇类、酮类、有机卤化物等。可极化物质——主要由C和H组成同时包含不饱和键。通常有:炔和芳香族化合物。我公司提供的色谱柱品种齐全,能够完全满足你分析的需要。如果你的样品是具有相似的化学性质的非极性组分的混合物,比如大多数石油馏分中的烃,你可以试用SE-30毛细管色谱柱,它按沸点顺序分离。如果你怀疑有芳族化合物,试着用有苯基的SE-54或OV-35柱。极性或可极化组分样品能够在中极性和/或可极化固定相色谱柱上进行分析,如有苯基或类似基团固定相,比如OV-17或OV-225柱。如果需要更高极性,可以选用聚乙二醇(PEG)固定相,即通常所说的W AX 固定相。 毛细管色谱柱规格的选择 1、膜厚 薄膜比厚膜洗脱组分快、峰分离好、温度低。一般而言,色谱柱的膜厚为0.25到0.5μm。对于流出达300℃的大多数样品(包括蜡、甘油三脂、甾族化合物等)能够很好的分析。对于更高的洗脱温度,可以用0.1μm的液膜。而厚液膜对于低沸点化合物有利,对于流出温度在100℃~200℃之间的物质,用1~1.5μm的液膜效果较好。超厚膜(3~5μm)用于分析气体、溶剂和可吹扫出来的物质,以增加样品组分与固定相的相互作用。另一个选择厚膜的原因是当用大口径柱时保持分离度和保留时间。由于这个原因,大口径柱都只有厚膜。厚膜的流失较大,温度极限必须随膜厚度增加而下降。 2、长度 一般情况,15m柱用于快速筛选简单混合物或分子量极高的化合物。30m柱是最普遍的柱长。超长柱(50、60或100m、150m)用于非常复杂的样品。 柱长度在柱性能上不是一个重要参数,例如:加倍柱长,恒温分析时间则加倍但峰分辨率仅增大约40%。如果分析只是比较好但不是特别好时,有比增加柱长度更好的办法来改进分析结果,如考虑更薄的膜,优化载气流量或用程序升温等。 分析活性极强的组分是一种特殊情况。如果样品与柱材质接触,那么峰会严重拖尾。较厚的膜、相对短的柱可以由于较少的柱材和较厚的固定液体掩盖其表面以屏蔽活性表面从而减少相互作用的机会。 3、内径 增加直径意味着需要更多的固定相,即使厚度不增加,也有较大的样品容量。同时也意味着降低了分离能力且流失较大。小口径柱为复杂样品提供了所需的分离,但通常因为柱容量低需要分流进样。如果分离度的降低能够接受的话,大口径柱可以避免这一点。当样品容量是主要的考虑因素时,如:气体、强挥发性样品、吹扫和捕集或顶空进样,大内径甚至PLOT 柱可能比较合适。同时色谱柱内径的选择中要考虑仪器的限制和要求。填充柱的进样口可以使用大口径毛细管柱(0.53mm内径),而小口径柱就不一定能够被连接在仪器上使用。毛细管柱的进样口一般可以用于所有内径范围的毛细管柱。(0.1mm、0.25mm、0.32mm、0.53mm)直接联用的GC/MSD和MSD需要小口径柱,因为真空泵不能处理大口径柱的大流量。查明你的整个系统看看你适合那些柱内径的色谱柱。

USP美国药典 233元素杂质-检查法

á233? ELEMENTAL IMPURITIES—PROCEDURES INTRODUCTION This chapter describes two analytical procedures (Procedures 1 and 2) for the evaluation of the levels of the elemental impuri-ties. The chapter also describes criteria for acceptable alternative procedures. By means of validation studies, analysts will confirm that the analytical procedures described herein are suitable for use on specified material. Use of Alternative Procedures The chapter also describes criteria for acceptable alternative procedures. Alternative procedures that meet the validation re-quirements herein may be used in accordance with General Notices and Requirements 6.30, Alternative and Harmonized Meth-ods and Procedures . Information on the Requirements for Alternate Procedure Validation is provided later in this chapter.Speciation The determination of the oxidation state, organic complex, or combination is termed speciation . Analytical procedures for spe-ciation are not included in this chapter, but examples may be found elsewhere in USP–NF and in the literature. PROCEDURES ? C OMPENDIAL P ROCEDURES 1 AND 2 System standardization and suitability evaluation using applicable reference materials should be performed on the day of analysis. Procedure and detection technique:Procedure 1 can be used for elemental impurities generally amenable to detection by inductively coupled plasma–atomic (optical) emission spectroscopy (ICP–AES or ICP–OES). Procedure 2 can be used for ele-mental impurities generally amenable to detection by ICP–MS. Before initial use, the analyst should verify that the proce- dure is appropriate for the instrument and sample used (procedural verification) by meeting the alternative procedure vali-dation requirements below. Sample preparation:Forms of sample preparation include Neat , Direct aqueous solution , Direct organic solution , and Indi- rect solution . The selection of the appropriate sample preparation depends on the material under test and is the responsibil-ity of the analyst. When a sample preparation is not indicated in the monograph, an analyst may use any of the following appropriately validated preparation procedures. In cases where spiking of a material under test is necessary to provide an acceptable signal intensity, the blank should be spiked with the same Target elements , and where possible, using the same spiking solution. Standard solutions may contain multiple Target elements . [N OTE —All liquid samples should be weighed.]Neat:Used for liquids or alternative procedures that allow the examination of unsolvated samples. Direct aqueous solution:Used when the sample is soluble in an aqueous solvent. Direct organic solution:Used where the sample is soluble in an organic solvent. Indirect solution:Used when a material is not directly soluble in aqueous or organic solvents. Total metal extraction is the preferred sample preparation approach to obtain an Indirect solution . Digest the sample using the Closed vessel diges-tion procedure provided below or one similar to it. The sample preparation scheme should yield sufficient sample to allow quantification of each element at the limit specified in the corresponding monograph or chapter. Closed vessel digestion:This sample preparation procedure is designed for samples that must be digested in a Concen-trated acid using a closed vessel digestion apparatus. Closed vessel digestion minimizes the loss of volatile impurities. The choice of a Concentrated acid depends on the sample matrix. The use of any of the Concentrated acids may be appropri-ate, but each introduces inherent safety risks. Therefore, appropriate safety precautions should be used at all times. [N OTE —Weights and volumes provided may be adjusted to meet the requirements of the digestion apparatus used.] An example procedure that has been shown to have broad applicability is the following. Dehydrate and predigest 0.5 g of primary sample in 5 mL of freshly prepared Concentrated acid . Allow to sit loosely covered for 30 min in a fume hood.Add an additional 10 mL of Concentrated acid , and digest, using a closed vessel technique, until digestion or extraction is complete. Repeat, if necessary, by adding an additional 5 mL of Concentrated acid . [N OTE —Where closed vessel digestion is necessary, follow the manufacturer’s recommended procedures to ensure safe use.] Alternatively, leachate extraction may be appropriate with justification following scientifically validated metal disposition studies, which may include animal studies, speciation, or other means of studying disposition of the specific metal in the drug product. Reagents:All reagents used for the preparation of sample and standard solutions should be free of elemental impurities,in accordance with Plasma Spectrochemistry á730?. ? P ROCEDURE 1: ICP–OES Standardization solution 1: 1.5J of the Target element(s) in a Matched matrix Standardization solution 2:0.5J of the Target element(s) in a Matched matrix Sample stock solution:Proceed as directed in Sample preparation above. Allow the sample to cool, if necessary. For mer-cury determination, add an appropriate stabilizer. Sample solution:Dilute the Sample stock solution with an appropriate solvent to obtain a final concentration of the Target elements at NMT 1.5J . Blank: Matched matrix 298 á233? Elemental Impurities—Procedures / Chemical Tests USP 40

气相色谱使用规范

气相色谱操作规范 1型号及参数 1.1型号 Perki nElmer Clarus GC 1.2参数 环境温度:+25C (士3C) 氢气输出压力:60-90Psi 载气压力:60-90Psi 电源电压:230V (士5% ,50/60Hz (士1% 功率:〉3000VA 2操作规范 2.1测量前的准备 在做样前用1ml的专用注射器吸取1ml标准气体对仪器进行标 ^定。 2.2操作步骤 2.2.1将气相色谱载气(氮气)总阀门打开,调节第二道阀门使输出 压力达到0.4Mpa。然后打开氢气和空气发生器,等上二十分钟,然后打开电脑,双击电脑桌面上软件。再把仪器电源打开。 2.2.2编辑仪器控制方法

运行TotalChrom色谱工作站软件,双击桌面上软件图标,进入软件,输入用户名:manager(小写),密码,三步法的操作获得定量结果: 建立新的方法文件、建立报告模板、建立序列表 2.221建立新的方法文件单击Method图标,开始编辑方法:Create new method: 新建方法,Load recently edited method: 调用最近使用过的方法。 222.1.1选择一种方式,点0K进入下一步; 2.2.2.1.2选择一种方式,点击0K进入下一步; Data Acquisitio n:数据采集参数选择; Data Channel:数据通道选择,用单一检测器时选A或B,两个检器同时使用时选Dual, Set Data Rate:数据采样频率的选择(此处可用默认值)。 2.2.2.1.3然后点Next进入下一步:lnstrument Control仪器控制参数:222.131 Oven/lnlets:柱温箱程序温度/进样口程序温度控制 Oven Ramp:柱温箱程序温度Rate:程序升温速率Temp:温度。Hold:温度保持时间如果不使用程序升温,只需将Rate1设为0,设置相应的Initial Temp 和Initial Hold 即可。 2.2.2.1. 3.2heated zone setpoints:加热区温度设置(即进样口温度设置),将要使用的进样口温度设置为需要的温度,不使用的进样口温度最好设置为零.如果进样口为PSS程序控制进样口,此处只能选择温度

气相色谱法检测时色谱柱的选择

气相色谱法检测时色谱柱的选择 气相色谱柱是样品中残留溶剂测定的理论与物质基础,所以对色谱柱的选择也是最关键的步骤。气相色谱柱可分为填充柱和毛细管柱两大类,其中填充柱又分玻璃柱和不锈钢柱;毛细管柱按柱__口直径一般又有0153mm和0132mm两种规格,前者又叫大口径毛细管柱,柱容量大,在残留溶剂测定中应用较多。由于毛细管柱造价高,中国药典2000年版结合中国国情,用填充柱测定,美国药典24版(USPXXIV)和英国药典2000年版(BP2000)要求用毛细管柱。从填料来分,填充柱一般选用高分子多孔小球系列(GDX101,GDX102,GDX103,GDX301,GDX401)直接测定。GDX的表面积大(1~500m2/g),有一定的机械强度,可在250℃以下应用。无论极性还是非极性物质,在这种固定相上的拖尾现象都降到最低限度;它和羟基的化合物亲和力极小,可使水、醇类物质大大提前流出柱子;氧化氮、HCN、NH3、SO2、COS等活泼气体可以很快流出,不干扰测定,这些优点对残留溶剂测定来说是比较理想的。 这类填料的应用约占填充柱测定残留溶剂的文献的90%。GDX既是性能优良的吸附剂,能直接作为气相色谱的固定相,直接用于气固分析,也能作为担体涂布 PEG系(PEG20M,PEG2M,PEG10000,PGE5000),DEGS(丁二酸二乙二醇酯),DG (缩二甘油),丙二醇乙二酸聚酯,OV- 225,SE52(苯基甲基硅酮)等固定液,用于残留溶剂测定,当然担体的选择也有多种,如6201、硅藻土、PoraparkQ等。在柱子的选择上,一般选用GDX系列就能解决问题,但对于某些样品,就需要用某些固定液来进行分离才能满足要求,如二甲基甲酰胺26。选择原则是相似相溶,对于醇、胺等能形成氢键的物质,除上面介绍的GDX外,也可选择极性固定液。另外也可将不同极性的固定液混合涂布在担体上进行分离27。 毛细管柱的种类也很多,如 OV-101,SE-54,CP-Sil-5CB28,AC-20,SE-30,HP-5,HP-20M,100%二甲基硅氧 烷,AT- 624,TFAP等,一般长10~30m不等。填充柱价格便宜,易得,一直占据溶剂残留量检测的主导地位,只是柱效较低,只有500~1000左右,分离复杂样品的能力差。杨绍英、陈志华在测定心痛定中两种残留溶剂时就分别用两种色谱条件,比较麻烦29。但填充柱仍然是我们的首要选择。张咏梅、洪铮在紫杉醇原料药中有机溶剂残留量的气相色谱分析中,应用GDX401填充柱同时检测甲醇、乙酸乙酯、二氯甲烷,方法准确可靠30。王卫、高立勤在测定盐酸莫索尼定有机溶剂残留量时以正丙醇为内标,用GDX-401填充柱测定乙醚和异丙醇的残留量,方法灵敏、准确、可信31。 邓湘昱也用GDX-401填充柱测定盐酸土霉素中残留甲醇,结果证明方法简单可靠32。黄剑英、顾以振用GDX-401填充柱、用恒温条件建立同时测定中国药典规定的7种溶剂的测定方法,方法分离度较好,准确可靠33。这些均说明填充柱在测定残留溶剂中的重要作用。近年来,毛细管柱应用越来越多,有取而代之的趋势。特别是近两年,文献报道关于残留溶剂测定的文章中,用毛细管柱测定的约占总数的90%,填充柱只占10%,由此可见其趋势。毛细管柱的理论塔板数约为10万左右,与填充柱相比柱效和灵敏度均要高的多,对复杂和微量残留溶剂的分析能力有极大的提高,所以选择毛细管柱一般都能解决分离问题。其中柱口直径为0153mm的大口径毛细管柱因其柱容量大尤其应用广泛。姚倩、李章万、张

USP色谱柱解释

L1和L8是美国药典(USP)规定的色谱柱编号,其实就是C18柱和NH2柱。下面是对应的色谱柱类型。 L1:十八烷基键合多孔硅胶或无机氧化物微粒固定相,简称C18或ODS L2:30~50um表面多孔薄壳型键合C18(ODS)固定相 L3:多孔硅胶微粒即一般的硅胶柱 L4:30~50um表面多孔薄壳型硅胶 L5:30~50um表面多孔薄壳型氧化铝 L6:30~50um实心微球表面包覆磺化碳氟聚合物-强阳离子交换固定相 L7:全多孔硅胶微粒键合C8官能团固定相简称C8柱 L8:全多孔硅胶微粒键合非交联NH2固定相简称NH2柱 L9:强酸性阳离子交换基团键合全多孔不规则形硅胶固定相 L10:多孔硅胶微球键合氰基固定相(CN)简称CN柱 L11:键合苯基多孔硅胶微球固定相简称苯基柱 L12:无孔微球键合季胺功能团的强阴离子填料 L13:三乙基硅烷化学键合全多孔硅胶微球固定相(C1)简称C1柱 L14:10um硅胶化学键合强碱性季铵盐阴离子交换固定相简称SAX柱 L15:已基硅烷化学键合全多孔硅胶微球固定相简称C6柱 L16:二甲基硅烷化学键合全多孔硅胶微粒固定相 L17:氢型磺化交联苯乙烯-二乙烯基苯共聚物,强阳离子交换树脂 L18: 3~10um全多孔硅胶化学键合胺基(NH2)和氰基(CN) L19:钙型磺化交联苯乙烯-二乙烯基苯共聚物,强阳离子交换树脂 L20:二羟基丙烷基化学键合多孔硅胶微球固定相(Diol)简称二醇基柱 L21:刚性苯乙烯-二乙烯基苯共聚物微球 L22:带有磺酸基团的多孔苯乙烯阳离子交换树脂 L23:带有季胺基团的聚甲基丙烯酸甲酯或聚丙烯酸酯多孔离子交换树脂 L24:表面含有大量羟基的半刚性聚乙烯醇亲水凝胶 L25:聚甲基丙烯酸酯树脂交联羟基醚(表面含有残余羧基功能团)树脂。能分离分子量100~5000MW范围的水溶性中性、阳离子型及阴离子型聚合物(用聚氧乙烯测定)的固定相 L26:丁基硅烷化学键合全多孔硅胶微球固定相 L27:30~50um的全多孔硅胶微粒

高效液相色谱法的分类及原理

高效液相色谱法的分类及其分离原理 高效液相色谱法分为:液-固色谱法、液-液色谱法、离子交换色谱法、凝胶色谱法。 1.液-固色谱法(液-固吸附色谱法) 固定相是固体吸附剂,它是根据物质在固定相上的吸附作用不同来进行分配的。 ①液-固色谱法的作用机制 吸附剂:一些多孔的固体颗粒物质,其表面常存在分散的吸附中心点。 流动相中的溶质分子X(液相)被流动相S带入色谱柱后,在随载液流动的过程中,发生如下交换反应: X(液相)+nS(吸附)<==>X(吸附)+nS(液相) 其作用机制是溶质分子X(液相)和溶剂分子S(液相)对吸附剂活性表面的竞争吸附。 吸附反应的平衡常数K为: K值较小:溶剂分子吸附力很强,被吸附的溶质分子很少,先流出色谱柱。 K值较大:表示该组分分子的吸附能力较强,后流出色谱柱。 发生在吸附剂表面上的吸附-解吸平衡,就是液-固色谱分离的基础。 ②液-固色谱法的吸附剂和流动相 常用的液-固色谱吸附剂:薄膜型硅胶、全多孔型硅胶、薄膜型氧化铝、全多孔型氧化铝、分子筛、聚酰胺等。 一般规律:对于固定相而言,非极性分子与极性吸附剂(如硅胶、氧化铜)之间的作用力很弱,分配比k较小,保留时间较短;但极性分子与极性吸附剂之间的作用力很强,分配比k大,保留时间长。 对流动相的基本要求: 试样要能够溶于流动相中 流动相粘度较小 流动相不能影响试样的检测 常用的流动相:甲醇、乙醚、苯、乙腈、乙酸乙酯、吡啶等。 ③液-固色谱法的应用 常用于分离极性不同的化合物、含有不同类型或不;数量官能团的有机化合物,以及有机化合物的不同的异构体;但液-固色谱法不宜用于分离同系物,因为液-固色谱对不同相对分子质量的同系物选择性不高。 2.液-液色谱法(液-液分配色谱法) 将液体固定液涂渍在担体上作为固定相。 ①液-液色谱法的作用机制 溶质在两相间进行分配时,在固定液中溶解度较小的组分较难进入固定液,在色谱柱中向前迁移速度较快;在固定液中溶解度较大的组分容易进入固定液,在色谱柱中向前迁移速度较慢,从而达到分离的目的。 液-液色谱法与液-液萃取法的基本原理相同,均服从分配定律:K=C固/C液 K值大的组分,保留时间长,后流出色谱柱。 ②正相色谱和反相色谱 正相分配色谱用极性物质作固定相,非极性溶剂(如苯、正己烷等)作流动相。 反相分配色谱用非极性物质作固定相,极性溶剂(如水、甲醇、己腈等)作流动相。