It works as hard as you do.

Agilent 6890N NetworkGC

? Rugged and reliable for unsurpassed uptime

? Advanced EPC ensures precision and accuracy of results

? Retention Time Locking for consistent results

? Accomplish more with fast GC capabilites

2

Acccomplish more with networking abilities ?Lets you share business and scientific data easily within a laboratory and across sites for fast and informed decision making.

?Incorporates local area network (LAN) technology as a standard feature, which makes it easy to link communication and control of multiple analytical instruments. With networking, you can work smarter,faster, and more economically.

Wide selection of inlets

Split/splitless (S/SL) capillary Packed purged injection port Cool on-column (COC)Cool on-column with solvent vapor exit (COC-SVE)Programmable temperature vaporizing (PTV)Volatiles interface (VI)?T emperature-programmable pre-column**

Agilent 7694E headspace sampler Purge and trap

Gas and liquid sampling valves Deans Switch for 2D GC Ambient air sampler and preconcentrator**Thermal desorber**Pyrolyzer**

HP-5MS)

?Midpolarity (HP-35, HP-35MS, DB-35, DB-35MS, DB-17, DB-17MS, HP-50+)

?High-polarity PEG (HP-Wax, HP INNOWax, DB-Wax, HP-FFAP)?PLOT (MoleSieve, PLOT Q, GS-GasPro, HP-PLOT Al 2O 3, HP-PLOT MoleSieve)

?Application-specific columns (DB-VRX, DB-Dioxin, DB-ALCl and ALC2)

*The 6890N network gas chromatograph is ready for attaching the Agilent 7683 series automatic liquid sampler.**Available through Agilent Channel Partners.

***For a complete list of Agilent columns and supplies, visit our Shopping Village on the World Wide Web at https://www.doczj.com/doc/da9909721.html,/chem

We have one thing in mind:

hard work.

Laboratories worldwide are looking for a GC solution that delivers reliability, performance, and reproducible results. And nothing produces these benefits like the Agilent 6890N Network GC. By integrating leading-edge technologies with an emphasis on quality manufacturing processes, the 6890N will bring a work ethic to your laboratory that’s matched only by your own.

6890N N e t w o r k G C :I t w o r k s a s h a r d a s y o u d o .

* Available through Agilent Channel Partners.6890N Network GC: It works as hard as you do. 3

More Productive than Any Other ECD

The Agilent 6890N micro-electron capture detector gives you greater throughput, less rework, reduced susceptibility to contamination, and expanded detection limits compared with any other electron capture detector. This detector offers the best sensitivity and linearity in the world. You do not have to concentrate extremely dilute samples and you do not have to dilute concentrated samples to get within the sample calibration range. Furthermore, this rugged, completely redesigned detector,which is optimized for capillary chromatography, lets you perform fast GC.

Decreased Calibration Time

You can manually enter existing calibration data and make a run with just one standard peak.The system can normalize the calibration table for you, allowing you to cut

calibration time and avoid re-running your calibration standards.

Increased Laboratory Efficiency

Clock-time programming allows you to set up runs for unattended operation whenever you want. The system can be ready to work when you get to your laboratory.Pre-run and post-run commands automatically prepare the system for the next sample.

An instrument that understands

an honest day’s work.

From operator interaction and sample input to separation, data acquisition, and analysis, the Agilent 6890N network GC system is Micro-Electron Capture Detector

6890N N e t w o r k G C :I t w o r k s a s h a r d a s y o u d o .

4

High Sample Throughput

The 6890N network GC system is already set up for the Agilent 7683 automatic liquid sampler,enabling fast and easy installation.

Single or dual injectors, equipped with either an 8-sample turret or a 100-vial sample tray, allow unattended operation. Using the 11-vial transfer turret with the tray and the solvent saving mode,you have enough solvent to run unattended eight times longer than before.

100-vial sample tray

8-sample turret for use without tray

Efficient Data Handling

The Agilent ChemStation for the 6890N network GC system lets you display, calibrate, and report data from up to four signals—without having to synchronize separate runs and merge results.This is

particularly efficient when you need to set up and report complex analyses.Agilent’s Cerity Networked Data System for Chemical QA/QC gives

you exactly what you need for your particular laboratory environment. Use-specific applications model your everyday tasks,making every step more efficient. Cerity NDS also connects you with your company’s intranet and the Internet for pulling in what you need to work efficiently or sending out results to your customers, fast.

Automatic Liquid Sampler

6890N Network GC:It works as hard as you do.

5

11-vial transfer turret for use with tray

Minimal Rework

The Agilent 6890N network GC system is the only GC system that automatically selects the optimum pressure-control mode for split and splitless analyses. Forward-pressure control is best for splitless injections. Along with a large inlet liner volume and pressure-pulse operation,this mode reduces discrimination, sample degradation, and sample loss caused by liner overload while maximizing sensitivity.

For split injections, the system automatically selects back-pressure control for linear split ratios over the entire usable split-ratio range and over wide column flow and pressure ranges. This reduces sample preparation and increases reproducibility and accuracy.

Automatic switching between forward-and back-pressure modes yields optimal results in less time and with less effort.

6890N N e t w o r k G C :I t w o r k s a s h a r d a s y o u d o .

6

The Agilent 6890N works as hard to meet regulatory requirements as it does to meet the needs of your lab. That’s why Agilent designed into the GC ChemStation a variety of features to answer the strict regulatory, certification, and quality control requirements of your industry. Agilent’s expert staff of engineers will work for you too— our installation qualification and operational qualification/performance verification services can help ensure your lab is in complete compliance.

A Record of All Events

Both the Agilent Cerity Networked Data System and Agilent ChemStation Plus family ease the burden of meeting regulatory and quality requirements.Both software programs, for example,record all system events during an analysis. This includes any anomalies or deviations from method setpoints.

System Performance Control

A system suitability table lets you easily set range limits on critical parameters to

establish and verify system performance.

Results that meet regulations—

and your expectations.

Good Laboratory Practice

Assured Method Security

Your original method, including all GC parameters and data files, can be stored in a single protected,

uneditable format for assured integrity. Furthermore,your methods and data are protected by a keyboard lock and multilevel security.

6890N Network GC:It works as hard as you do.

7

You want to keep your cost-per-analysis down— but not at the cost of unreliable results. That’s why Agilent designed the 6890N to do much of the work for you. It’s easy to operate, with minimal time required for training, prep and data handling.You’ll save time by entering all GC parameters electronically. Once set, they remain precisely the same for accurate and reproducible results you can count on, every time, with every operator, and with minimal rework.

Unsurpassed Reproducibility Full electronic pneumatics control (EPC) makes it fast and easy to set all pressures and flows.Our fourth-generation EPC keeps these setpoints constant from run to run,providing excellent retention time reproducibility.

Simplified Control

The 6890N keyboard simplifies parameter entry and system control.The keyboard displays four parameters of your choice,giving you instant access to system information— for fast,

effective diagnostics and troubleshooting. All parameters can be stored and recalled at the touch of a button.

Retention Time (min)Run Peak 1Peak 218.3778.63228.377

8.6323

8.3778.63348.3778.63258.376

8.6326

8.3748.63078.375

8.6318

8.3758.63198.3748.630108.374

8.63011

8.3758.631128.3768.632138.3768.632148.376

8.63215

8.3768.632Average 8.376

8.632Standard

0.001 0.001

Deviation

Method setup that’s fast,

results that stay true.

Fourth-Generation Pneumatics Control

6890N N e t w o r k G C :I t w o r k s a s h a r d a s y o u d o .

8

Different Detector, Different Location,Different Operator—Same Results

Retention Time Locking (RTL) software is a powerful productivity tool that lets you reproduce exactly the same results on multiple Agilent GCs with EPC—configuration to configuration, location to location,operator to operator. This revolutionary technology allows retention times to be reproduced between Modularity to Meet Changing Needs Modular design of system components lets change or upgrade GC MSD Method Locked to FID Method Mixture of 25 Pesticides

Retention Time Locking with GC and GC/MSD ChemStation

6890N Network GC:It works as hard as you do.

9

6890N N e t w o r k G C :I t w o r k s a s h a r d a s y o u d o .

Sampling Flexibility

The Agilent automatic liquid sampler lets you mimic manual injection. At the same time, you get the convenience of automated injection. Other benefits include improved

precision and accuracy (with the industry’s fastest injection speed) and the ability to sample individual layers in a vial for automated micro-liquid/liquid extraction and ambient

headspace analysis.

No Sample Concentration

The system’s automatic liquid sampler offers large-volume injection, eliminating sample

concentration steps. Using the programmable temperature vaporizing inlet or cool on-column inlet, you can inject up to 50 μL in a single injection.If you are using a programmable temperature vaporizing inlet, you can inject up to 500 μL, with multiple injections. This gives you highly sensitive quantitation—especially useful for mass selective

detection and atomic emission detection.

With enhanced technologies, the 6890N works harder than ever to increase your lab’s performance. Both injection and headspace sampling are automated, which means less manual work and even more precise results. You’ll enjoy quicker turnaround time, lower cost per analysis, and less waste.

Small-Volume Sampling

Multiphase Sampling Ambient Headspace

Sampling

T ake the work out

of manual sample prep.

Large-Volume Injection

10

No Sample Preparation

Headspace sampling can eliminate sample preparation by

introducing volatile components automatically—from virtually any matrix—directly into the GC. A low-volume, highly inert volatiles interface is optimized for headspace-GC analysis, preventing

sample loss or degradation. Agilent headspace instrument control is fully integrated into the Agilent GC ChemStation software.

Reduced Derivatization

A cool on-column inlet offers a gentle environment for thermally labile compounds. This minimizes the need for derivatization and improves the accuracy of sample characterization.

6890N Network GC:It works as hard as you do.

11

6.00 6.00 8.00 0.00 2.00 4.00 6.00 8.00

6.00 6.00 8.00 0.00 2.00 4.00 6.00 8.00

2

3

3

4

Standard GC

Fast GC HP-INNOWax 60m x 0.32mm x 0.5μm

HP-INNOWax 25m x 0.2mm x 0.313μm

Styrene

5 7.510 12.5 15 17.5 200.5 1 1.5 2 2.5min

min

The Agilent 6890N network GC system lets you

Real GC—T en Times Faster

The Agilent 6890N network GC system provides everything you need for fast GC. This includes fast automatic injection, split/splitless inlets,0.1-mm capillary columns, high-speed detectors, fast data handling, and method translation software. You get real chromatography, accurately and consistently, two or five or even ten times faster than standard GC.And you can switch back to standard GC with ease.

Waste no time,

results come in minutes.

6890N N e t w o r k G C :I t w o r k s a s h a r d a s y o u d o .

12

Easy Translation to Fast GC

Free method translation software lets you transfer current

methods to faster methods in minutes.You can see the impact of parameter changes on analysis speed—before you run a sample.At the same time, the software identifies any potential method or instrument constraints so that you know what will work before investing significant time and money.

6890N Network GC:It works as hard as you do.

13

2D GC Made Easy

Setup and operation of 2D GC is made reliable and easy to use by combining Micro-fluidic and EPC technologies. This unique software tool minimizes operator effort by automatically calculating restrictions and pressures. The reproducibility of

retention times of the 6890N GC results in improved accuracy and reliability. 2D GC is available pre-configured by Agilent, as a standard option, or as an accessory for existing 6890N GC systems.

2D GC Using Micro-Fluidic T echnology

Agilent’s patented Micro-fluidic technology greatly improves the performance of 2D GC. Internal volumes are optimized to

maximize separation efficiency and eliminate peak tailing. Each device is deactivated to produce superior results even for trace analysis of chemically active compounds. A new fitting and ferrule design simplifies column installation and eliminates leakage even with repeated oven temperature programming to final temperatures over 400 C.

Agilent Columns and Supplies— The Perfect Fit

For greater confidence in your GC results,you can optimize your total system with quality Agilent columns and supplies—the perfect fit for the Agilent 6890N network GC system. A wide range of GC columns,supplies, kits, and accessories is designed,manufactured, and tested to rigorous Agilent specifications, under a quality system registered to ISO 9001. Why risk compromising your analytical results with anything less than genuine Agilent consumables?

Backed by Agilent Support

You can also ensure the best performance from your 6890N by relying on a variety of Agilent-brand services. Whether you need assistance in hardware or software installation, performance checks, or on-going technical support, Agilent can help maintain reliable operations over the life of

your instrument.

Created for endurance—

now and for years to come.

6890N N e t w o r k G C :I t w o r k s a s h a r d a s y o u d o .

14

The Agilent 6890N network GC system incorporates the lessons learned from 40 years of producing the world’s best-selling and most reliable GCs. In fact, labs turn to Agilent because they know the instruments will perform accurately and consistently over extended periods— and when they do replace or upgrade a system, they regularly return to Agilent.You can be sure your Agilent instrument will prove to be a workhorse for your lab, too. Each 6890N network GC system ships with a Declaration of Conformity that certifies it has passed stringent safety tests, ensuring the instrument will meet Agilent’s performance specifications. We back it all up with our Agilent Value Promise that guarantees you’ll have at least 10 years use from your 6890N (see back panel for details). Now that’s a hard-working promise.

Special Service Bundles

Agilent offers special service bundles that are designed to meet the needs of your laboratory. Essential services include:? T elephone support to resolve hardware problems

? At-your-site instrument service plus consumables used for repairs ? Off-site instrument repair service ? Annual preventative maintenance

Agilent customer service centers are located worldwide. With Agilent support, you can reduce operational costs, increase laboratory productivity, and lighten the load of regulatory compliance.

Agilent has a series of convenient 6890 system GC Web-based training modules. You can learn at your desk—with minimal disruption to work schedules—or wherever you can connect to the Internet. e-Learning gives you focused instruction in instrument theory, operation, routine maintenance, as well as common problems and solutions.

You can view module descriptions, try a demo, register, and purchase

modules by visiting https://www.doczj.com/doc/da9909721.html,/chem/elearning.

GC e-Learning On-Demand and Live Course Titles and Descriptions

See how Agilent training

can work for you.

6890N Network GC:It works as hard as you do.

15

Product Number Course Title

Description

R1691A

6890 GC Split Inlet Mode Operation

This module teaches you the basic theory and operation of the 6890 GC split/splitless capillary inlet when operating in the split mode.

R1692A 6890 GC Splitless Inlet Mode Operation

This module teaches you the basic theory and operation of the 6890 GC split/splitless capillary inlet when operating in the splitless mode.

R1693A 6890 GC Purged Packed Inlet Operation

This module teaches you the basic theory and operation of the 6890 GC purged packed inlet.

R1694A Capillary Columns Theory and Operation

This self-paced e-Learning module teaches you the basic theory and operation of capillary columns.

R1695A 6890 GC Keyboard Operation

This self-paced e-Learning module teaches you the basic operation of the 6890 GC keyboard. It is designed to help you to understand all of the keys to gain the maximum benefit from your GC.

R1696A 6890 GC FID Theory and Operation This module teaches you the basic theory and operation of the FID.

R1697A 6890 GC ECD Theory and Operation This module teaches you the basic theory and operation of the ECD.

R1698A 6890 GC TCD Theory and Operation This module teaches you the basic theory and operation of the TCD.

R1699A GC Automatic Liquid Sampler Operation

This module teaches you the basic operation of the Agilent automatic liquid sampler system (ALS). It is designed to help you gain the maximum productivity from the ALS.

R1700A Logical GC Troubleshooting

This module teaches logical steps in troubleshooting GC system problems.These steps are designed to identify the source of the problem quickly and prevent the troubleshooting task from becoming overwhelming.

Find out more today

For more information about how you can benefit from the Agilent 6890N Network GC system, Agilent’s support services, or Agilent training courses, visit us online or call toll free:

https://www.doczj.com/doc/da9909721.html,/chem

1-800-227-9770 (in the U.S. and Canada)

Outside the U.S. and Canada, please call your local Agilent

T echnologies analytical sales office or authorized Agilent

T echnologies distributor.

Information, descriptions, and specifications in this publication

are subject to change without notice.

? Agilent T echnologies, Inc. 2004

Printed in the USA

June 2, 2004

5989-0973EN A Sizable Promise

For nearly two decades, Agilent T echnologies has been improving the way laboratories get results, perform their processes, and enhance their businesses. And the Agilent 6890N Network GC is no exception. With exemplary performance and outstanding ease-of-use packed into its compact frame, the 6890 will help improve the efficiency and productivity of your lab.

The Agilent Value Promise–

10 years of guaranteed value

In addition to continually evolving products, we offer something else unique to the industry-our 10-year value guarantee. The Agilent Value Promise guarantees you at least 10 years of instrument use from your date of purchase, or we will credit you with the residual value of that system toward an upgraded model. Not only does Agilent ensure a safe purchase now, we help ensure your investment is as valuable to you in the long run.

Information at your fingertips

Stay up-to-date on the 6890N Network GC and other Agilent products. Register at https://www.doczj.com/doc/da9909721.html,/chem to receive exclusive benefits, such as:? Personalized email notifications that reflect your selected interests

? Access to how-to videos, chromatogram libraries,

application notes, and more

? Free firmware and software updates

? Fast enrollment for e-Seminars and other training

安捷伦7890A气相色谱仪操作规程

一、目的 建立一个Agilent 7890A气相色谱仪的标准操作程序。 二、范围 本规程适用于Agilent 7890A气相色谱仪的操作。 三、责任 Agilent 7890A气相色谱仪的相关操作人员 四、程序 1、仪器组成 由Agilent 7890A气相色谱仪主机,气源(氢气发生器、氮气瓶、空气发生器或高纯空气),检测器(FID和ECD或FPD),自动进样器,Agilent Chemstation色谱工作站和HP LaserJet Pro 400 M401d打印机组成。 2、环境要求 推荐操作环境温度:15℃~35℃,湿度:50%~60%,无冷凝。 电源电压:220VAC,±10%。 气源要求:纯度应为99.995%~99.9995%(N )。 2 3、技术参数 3.1 柱温箱:操作温度: -60℃~450℃;可设置的最大升温速度:120℃/min;程序温度的梯度数:21个;每次分析方法可运行最长时间:999.99min。 3.2 进样口:安装有两个进样口;最大可设置的温度为:400℃;压力设置范围为:0~100psi。 ,最大可设置的3.3 检测器:FID:最大可设置的温度为:450℃;ECD:放射源: 63Ni,尾吹气:N 2 温度为:400℃;FPD,尾吹气:氮气,最大可设置的温度为:250℃。 4、操作步骤 4.1 Agilent 7890A气相色谱仪主机操作 4.1.1 打开主机门,将色谱柱(毛细管柱)安装在检测器及相应的进样口上。 (高纯氮)钢瓶,将低压调节至0.5MPa,如使用FID(FPD)检测器则还需打开空气发4.1.2 打开N 2 生器(空气钢瓶)和氢气发生器。 4.1.3 打开总电源开关,打开主机电源钮,主机自动进行运行试验,随即在显示窗口中显示试验通过。 4.2 Chemstation色谱工作站操作 4.2.1 打开Chemstation色谱工作站计算机的电源开关。。 4.2.2 若需要进行样品测定,用鼠标双击Windows操作系统界面上的“GC-01(联机)”图标与仪器连接;若仅需要进行数据分析,用鼠标双击“GC-01(脱机)”图标。[或“GC-02(联机)”和“GC-02

安捷伦气相色谱仪系统简介

气相色谱系统 7890 A 气相色谱系统 6890N 气相色谱系统 6850 气相色谱仪 6820 气相色谱系统 7820 A 气相色谱仪(厂家推荐, 全中文操作界面) 新!7000A 三重串联四级杆质谱系统 5975C 系列质谱系统 3000 微型气相色谱仪 1 Agilent 7890A GC 系统 优异仪器性能 成就化学理想 安捷伦7890A GC 为安捷伦公司40年领导GC 技术的历史谱写了激动人心的新篇章。它为您提供了所需的一切,包括先进的分离能力, 强效的新功能和仪器智能化实时自监测,从而将您实验室的GC 和GC/MS 性能提升到一个新水平。更快的柱箱降温速率和反吹功能,使您的分析时间更短, 样品的分析成本更低。第五代电子气路控制 (EPC)和数字电路为压力设定和保留时间锁定(RTL)的精度 (0.001psi ) 设置了新的标准,使安捷伦7890GC 具有前所未有的可靠性。 特点 多模式进样口包括分流/不分流, 升温,以及大容量进样器功能。 每个分流/不分流 (SSL 进样口)都采用了新的方便的扳转式顶盖设计,使您能在30秒内更换进样口衬管 - 无需特殊的工具或培训 突破性的微板流路控制技术实现了柱箱内可靠的无泄漏连接,提高了工作效率和数据完整性,为复杂的GC 分析提供了通用、可靠的解决方案 。 低热容技术为极速分析周期和高效生产提供了迅速加热以及冷却的毛细管色谱柱 Blos NPD 可提供更稳定的运行和更长的使用寿命。 安捷伦7693自动液相进样器具备对所有气相自动进样品的极快进样时间,附带对150-via 容器的同时注射, 并且加强了样品制备功能。

安捷伦气相色谱6890N软件操作规程

Agilent 6890N GC ( For Chemstation B02.01) 现场培训教材 安捷伦科技有限公司 化学分析仪器部

一、培训目的: ?基本了解6890N硬件操作。 ?掌握化学工作站的开机,关机,参数设定, 学会数据采集,数据分析的基本操作。 二、培训准备: 1、仪器设备:Agilent 6890N GC ?进样口: 填充柱进样口(PP);毛细柱进样口(S/SL); 冷柱头进样口(COC); PTV进样口。 ?检测器:FID;TCD;u ECD; NPD;FPD。 ?色谱柱:P/N 19091J-433, HP-5毛细柱:30m,ⅹ320μχ0.25μ ?注射器:自动液体进样器(ALS)用10ul注射器或手动进样用10ul注射器。 ?进样体积: 1 ul。 2、气体准备: ?FID,NPD,FPD : 高纯H2 (99.999%),干燥无油压缩空气。 ?uECD: 高纯N2 (99.999%) ?载气, 高纯N2 (99.999%)或高纯He (99.999%)。

基本操作步骤: (一)、开机: 1、打开气源(按相应的所需气体)。 2、打开计算机,进入Windows 2000 (或Windows XP)画面。 3、打开6890N GC电源开关。(6890N 的IP地址已通过其键盘提前输入进6890N) 4、待仪器自检完毕,双击“Instrument 1 Online”图标,化学工作站自动与6890N通讯, 此时6890N 显示屏上显示“Loading......”。进入的工作站界面如下图: 5、从“View”菜单中选择“Method and run control”画面,点击“Instrument diagram”, “Sampling Diagram”,使其命令前有“√”标志,来调用所需的界面。 (二)数据采集方法编辑: 1.开始编辑完整方法: 从“Method”菜单中选择“Edit Entire Method”项,如下图所示,选中除“Data Analysis”外的三项,点击“OK”,进入下一画面。

AgilentBC气相色谱质谱联用仪操作规程

1. 开机 1)打开载气钢瓶控制阀,设置分压阀压力至 0.5Mpa 。 2 ) 打开计算机,登录进入 Windows 7 系统。 3)打开 7000C(若 MSD真空腔内已无负压则应在打开 MSD电源的同时用手向右侧推真空腔的侧板直至侧面板被紧固地吸牢),等待仪器自检完毕。 4)桌面双击 GC-MS 图标,进入 MSD 化学工作站 5)在上图仪器控制界面下,单击视图菜单,选择调谐及真空控制进入调谐与真空控制界面 , 在真空菜单中选择真空状态,观察真空泵运行状态,此仪器真空泵配置为分子涡轮泵,状态显示涡轮泵转速涡轮泵转速应很快达到 100 % ,否则,说明系统有漏气,应检查侧板是否压正、放空阀是否拧紧、柱子是否接好。 2. 调谐 调谐应在仪器至少开机 2 个小时后方可进行,若仪器长时间未开机为得到好的调谐结果将时间延长至 4 小时。 1)首先确认打印机已连好并处于联机状态。 2 ) 在操作系统桌面双击 7000C 图标进入工作站系统。 3)在上图仪器控制界面下,单击仪器菜单,选择MS调谐进入调谐与真空控制界面。 4 ) 进行自动调谐 , 调谐结果自动打印。 5 ) 如果要手动保存或另存调谐参数,将调谐文件保存到 atune.u 中。 6 ) 然后点击视图然后选择仪器控制返回到仪器控制界面。注意 : 自动调谐文件名为 ATUNE.U 标准谱图调谐文件名为 STUNE.U 其余调谐方式有各自的文件名 . 3. 样品测定 3.1 方法建立 1 ) 7890B配置编辑 点击仪器菜单 , 选择编辑 GC 配置进入画面。在连接画面下,单击【仪器】【GC 参数】,设置ALS,进样口,色谱柱,柱温箱参数。 2)分流不分流进样口参数设定,点击【仪器】【GC参数】在空白框内输入进样口的温度为250℃,选择隔垫吹扫流量模式标准,输入隔垫吹扫流量为 3ml/min 。对于特

如何选择色谱柱

如何选择色谱柱? 要选择色谱柱,首先需要确定要使用的是填充柱还是毛细管柱。 填充柱或毛细管柱?填充柱比毛细管柱具有更高的样品容量,虽然这一差距由于HP 发明了大孔 530mm 毛细管而大大缩小。检测器灵敏度的改进也减少了对大剂量样品的需要。填充柱可能具有优势的领域是气体样品的分析。 对于几乎所有的其他样品,毛细管柱具有高很多的效率(窄峰),这可以大大改进峰分离。实际上,分离能力很大,以至于许多分析物在很简单的分析中使用非常短的色谱柱就可以完成分离了。节省的时间可以直接转化为循环时间的缩短和样品通量的增加。 对于新的或更新的方法,如果没有非常具有说服力的理由使用填充柱的话,我们推荐使用毛细管柱。 色谱柱材料 这种材料必须尽可能是惰性的,尤其是对于痕量分析或容易拖尾的化合物,例如硫醇或类似的活性化合物。对于毛细管柱,熔融石英是可选的材料。 有两种类型的熔融石英毛细管柱:壁涂开管柱 (WCOT) 色谱柱和多孔层开管柱(PLOT) 色谱柱。WCOT 色谱柱是固定相液膜涂渍在去活的色谱柱壁上。这是气相色谱中最常用的色谱柱。PLOT 色谱柱中固定相是固体物质涂渍到色谱柱壁上。填充柱可以是玻璃或金属,通常是不锈钢的。金属虽然比较有活性,但其对非极性物质比较稳定。但是如果样品中有极性组分需要分析,请选择玻璃柱。如果玻璃柱还是活性强(引起峰拖尾、样品丢失等),请进行去活处理。 固定相 选择毛细管柱时,首先需要确定是否需要 PLOT 色谱柱。下面是 3 种 PLOT 色谱柱的典型应用领域: 分子筛不挥发气体,对水比较敏感 二乙烯基苯 (DVB) — HP-PLOT Q C1 到 C3 全部异构体的分离,部分 C4 和更高的(直到 C14)的异构体分离,极性化合物,挥发性溶剂可以允许含水 氧化铝 Al2O3 C1 到 C10 异构体的分离, 对水比较敏感 如果上面提到的应用没有感兴趣的,则您可以选择一个 WCOT 类型色谱柱。 当面对一种未知样品时,首先尝试目前在 GC 上的色谱柱。如果不能获得满意的结果,请考虑所了解的样品信息。基本原理是分析物与具有相似化学性质的固定相间更容易相互作用。这意味着了解的样品信息越多,越容易找到最佳分离固定相。 最重要的步骤是确定分析物的极性特征: § 非极性分子—通常只包含碳氢原子没有偶极距。 § 直链碳氢化合物(n-烷烃)是非极性化合物的例子。 § 极性分子—主要包含碳氢,也包含氮、氧、磷、硫或卤原子。例如醇、胺、硫醇、酮、腈、有机卤化物等。 § 可极化的分子—主要包含碳氢,也包含不饱和键。例如烯烃、炔烃和芳香族化合物。 针对特定分离需要提供正确的固定相:样品是具有相同化学类型的非极性物质的混合物吗?例如大多数石油馏分中的碳氢化合物?请尝试非极性色谱柱,如 HP-1,可以将它们按(近似)沸点顺序分离。如果怀疑有一些芳香族化合物,请尝试 HP-5 或 HP-35 等适用苯基化合物的色谱柱。

安捷伦气相色谱仪7890B入门知识

气相五大部分 1气源:纯度五个九以上,高纯,捕集阱;压力输出压0.4~0.6MPa 2气化室:加热使样品从液体变成气体;进样口分流不分流,若分流比是20:1,则若进样量为1uL,仍过量,那么气化时,分为21份,一份进柱子,余下20份 通过分流捕集阱出来,若不分流,则是痕量分析,没必要分流。 隔垫:密封作用,避免样品不进柱子;有洞朝上,每50针更换;拧到C型 钢圈和绿色螺母1mm,指甲刚好塞进去;过紧,针易断,过松,漏气 衬管:有表面钝化层,不易吸附带电物质,金属的易吸附带电样品,造成影 响,有杂峰;分为分流/不分流(玻璃丝小者);O型圈,密封作用 分流捕集阱:成分活性炭,起到分流作用;样品中的有机试剂会对其产生腐蚀作用 3进样器:进样塔,大小花圈对应绿色螺母和柱子 A/B洗针瓶,置内塞,倒奶嘴,有最低刻度线,内置样品溶剂 W废液瓶,全放满,随机打入,3Wa 2Wb 隔垫吹扫针外壁残留 4 色谱柱:参数:货号(购买提供,唯一标识);填料材质:HP-5,极性决定分析样品;柱长30m;直径0.31mm,越细,分离效果越好,但是柱压大;膜厚:0.25um,意为柱子内层所涂材质的厚度,膜越厚,效果越好;适应温度上限325℃,持续烘烤,350℃,瞬间达到 破坏色谱柱(玻璃丝材质):超温使用,进错误试剂(水样,强酸,强碱),从中间折断,空气进入(水氧气会氧化涂料),干烧不通气 安装:先后穿过隔垫、柱螺母、石墨垫(小头朝上),割柱子时,进样口处留4~6mm,先用手拧紧,后用扳手紧180° 5检测器:后检测器FPD ,色谱柱一次穿过柱螺母、石墨垫,利用红色工具,前端露出0~1mm,拧紧固定,取下红色工具,连接检测器,手紧螺丝后,利用扳手紧45°(左拧松,右拧紧) FPD 检测硫磷,更换滤光片时,光电倍增光电压关掉,镜头有方向箭头朝右,工作参数:温度,氢气、空气、尾气,全开60 高纯氢气99.9995% 干燥无油压缩空气

Agilent 化学工作站操作说明

Agilent 化学工作站操作说明

目录 第一章 工作站和色谱仪的开启 (1) 第二章 编辑分析方法 (2) 第三章 运行方法 (31) 第四章 数据分析 (33) 第五章 校正设置 (39) 第六章 工作站的配置 (47)

一、工作站和色谱仪的开启 1.1 检查色谱仪主机的所有气源是否连接好、所有气体是否打开并进行试漏。 1.2 确保上述情况完好,开色谱仪主机电源并等待通过自检。开计算机电源。 图1:工作站开启界面 1.3 在计算机屏幕上单击Start选择Programs再选择ChemStations双击 Instrument 1 Online.等待GC与工作站的连接出现初始状态。如有第二通道则有 Instrument 2 Online 存在。 图2:工作站开启图标 1.4 也可在计算机屏幕上双击图标。 1.5 Instrument 1 Online为连接GC状态、Instrument 1 Offline为脱离GC状态。 先开Instrument 1 Online可继续打开Instrument 1 Offline、先开Instrument 1 Offline不能继续打开Instrument 1 Online。 1.6 注意:在Instrument 1 Offline状态下改动分析方法如果存储则Instrument 1 Online下的方法也将改动。

1.7 本操作说明均指在Instrument 1 Online状态并安装EPC。 二、编辑分析方法 在这只对仪器控制和数据采集参数进行说明,数据分析处理将在后面说明。 图3 显示菜单 2.1 此菜单提供显示的画面,前三项与选择是方法和运行控制界 面、数据分析界面还是报告设计界面相同,Show Top Toolbar为快捷方式工具栏(本界面最上的图标一栏),Show Status Toolbar为仪器状态栏(本界面第二图标栏),其他经常使用的为在线信号(Online Signals)1或2和仪器状态(Instrument Actuals)及化学工作站状态(Chemstation Status)。在界面的右侧有帮助(Help)菜单可随时查阅。

安捷伦气相色谱操作规程-

1、目的:建立安捷伦7890A型气相色谱仪标准操作程序。 2、范围:适用于Agilent 7890A,FID检测器及Chemstation软件的气相色谱仪。 3、责任者:操作者 4、程序: 4.1 操作前准备 4.1.1 色谱柱的检查与安装首先打开柱温箱门看是否是所需用的色谱柱,若不是则旋下毛细管柱按进样口和检测器的螺母,卸下毛细管柱。取出所需毛细管柱,放上螺母,并在毛细管柱两端各放一个石墨环,然后将两侧柱端截去1~2mm,进样口一端石墨环和柱末端之间长度为4~6mm,检测器一端将柱插到底,轻轻回拉1mm左右,然后用手将螺母旋紧,不需用板手,新柱老化时,将进样口一端接入进样器接口,另一端放空在柱温箱内,检测器一端封住,新柱在低于最高使用温度20~30℃以下,通过较高流速载气连续老化24小时以上。 4.1.2 气体流量的调节 4.1.2.1 载气(N2 or He)开启氮气钢瓶高压阀前,首先检查低压阀的调节杆应处于释放状态,打开高压阀,缓缓旋动低压阀的调节杆,调节至约0.6MPa。 4.1.2.2 氢气打开氢气钢瓶or氢气发生器主阀,调节输出压至0.4MPa。 4.1.2.3 空气启动的空气压主机,调节输出压至0.4MPa。 4.1.3 检漏用检漏液检查柱及管路是否漏气。 4.2 主机操作 4.2.1 接通电源,打开电脑,进入英文windows NT主菜单界面。然后开启主机,主机进行自检,自检通过主机屏幕显示power on successul,进入Windows 系统后,双击电脑桌面的(Instrument Online)图标,使仪器和工作联接。 4.2.2 编辑新方法 4.2.2.1 从“Method”菜单中选择“Edit Entire Method”,根据需要钩选项目,“Method Information”(方法信息),“Instrument/Acquisition”(仪器参数/数据采集条件),“Data Analysis”(数据分析条件),“Run Time Checklist”(运行时间顺序表),确定后单击“OK”。 4.2.2.2 出现“Method Commons”窗口,如有需要输入方法信息(方法用途等),单击“OK”。 4.2.2.3 进入“Agilent GC Method: Instrument 1”(方法参数设置)。 4.2.2.4 “Inlet”参数设置。输入“Heater”(进样口温度);“Septum Purge Flow”(隔垫吹扫速度);拉下“Mode”菜单,选择分流模式或不分流模式或脉冲分 流模式或脉冲不分流模式;如果选择分流或脉冲分流模式,输入“Split Ratio”(分流比)。完成后单击“OK”。 4.2.2.5 “CFT Setting”参数设置。选择“Control Mode”(恒流或恒压模式),如选择恒流模式,在“Value”输入柱流速。完成后单击“OK”。 4.2.2.6 “Oven”参数设置。选择“Oven Temp On”(使用柱温箱温度);输入恒温分析或者程序升温设置参数;如有需要,输入“Equilibration Time”(平衡时间),“Post Run Time”(后运行时间)和“Post Run”(后运行温度)。完成后单击“OK”。 4.2.2.7 “Detector”参数设置。钩选“Heater”(检测器温度),“H2 Flow”(氢气流速),“Air Flow”(空气流速),“Makeup Flow”(尾吹速度N2),“Flame”(点火)和“Electrometer”(静电计),并对前四个参数输入分析所要求的量值。完成后单击“OK”。

气相色谱法检测时色谱柱的选择

气相色谱法检测时色谱柱的选择 气相色谱柱是样品中残留溶剂测定的理论与物质基础,所以对色谱柱的选择也是最关键的步骤。气相色谱柱可分为填充柱和毛细管柱两大类,其中填充柱又分玻璃柱和不锈钢柱;毛细管柱按柱__口直径一般又有0153mm和0132mm两种规格,前者又叫大口径毛细管柱,柱容量大,在残留溶剂测定中应用较多。由于毛细管柱造价高,中国药典2000年版结合中国国情,用填充柱测定,美国药典24版(USPXXIV)和英国药典2000年版(BP2000)要求用毛细管柱。从填料来分,填充柱一般选用高分子多孔小球系列(GDX101,GDX102,GDX103,GDX301,GDX401)直接测定。GDX的表面积大(1~500m2/g),有一定的机械强度,可在250℃以下应用。无论极性还是非极性物质,在这种固定相上的拖尾现象都降到最低限度;它和羟基的化合物亲和力极小,可使水、醇类物质大大提前流出柱子;氧化氮、HCN、NH3、SO2、COS等活泼气体可以很快流出,不干扰测定,这些优点对残留溶剂测定来说是比较理想的。 这类填料的应用约占填充柱测定残留溶剂的文献的90%。GDX既是性能优良的吸附剂,能直接作为气相色谱的固定相,直接用于气固分析,也能作为担体涂布 PEG系(PEG20M,PEG2M,PEG10000,PGE5000),DEGS(丁二酸二乙二醇酯),DG (缩二甘油),丙二醇乙二酸聚酯,OV- 225,SE52(苯基甲基硅酮)等固定液,用于残留溶剂测定,当然担体的选择也有多种,如6201、硅藻土、PoraparkQ等。在柱子的选择上,一般选用GDX系列就能解决问题,但对于某些样品,就需要用某些固定液来进行分离才能满足要求,如二甲基甲酰胺26。选择原则是相似相溶,对于醇、胺等能形成氢键的物质,除上面介绍的GDX外,也可选择极性固定液。另外也可将不同极性的固定液混合涂布在担体上进行分离27。 毛细管柱的种类也很多,如 OV-101,SE-54,CP-Sil-5CB28,AC-20,SE-30,HP-5,HP-20M,100%二甲基硅氧 烷,AT- 624,TFAP等,一般长10~30m不等。填充柱价格便宜,易得,一直占据溶剂残留量检测的主导地位,只是柱效较低,只有500~1000左右,分离复杂样品的能力差。杨绍英、陈志华在测定心痛定中两种残留溶剂时就分别用两种色谱条件,比较麻烦29。但填充柱仍然是我们的首要选择。张咏梅、洪铮在紫杉醇原料药中有机溶剂残留量的气相色谱分析中,应用GDX401填充柱同时检测甲醇、乙酸乙酯、二氯甲烷,方法准确可靠30。王卫、高立勤在测定盐酸莫索尼定有机溶剂残留量时以正丙醇为内标,用GDX-401填充柱测定乙醚和异丙醇的残留量,方法灵敏、准确、可信31。 邓湘昱也用GDX-401填充柱测定盐酸土霉素中残留甲醇,结果证明方法简单可靠32。黄剑英、顾以振用GDX-401填充柱、用恒温条件建立同时测定中国药典规定的7种溶剂的测定方法,方法分离度较好,准确可靠33。这些均说明填充柱在测定残留溶剂中的重要作用。近年来,毛细管柱应用越来越多,有取而代之的趋势。特别是近两年,文献报道关于残留溶剂测定的文章中,用毛细管柱测定的约占总数的90%,填充柱只占10%,由此可见其趋势。毛细管柱的理论塔板数约为10万左右,与填充柱相比柱效和灵敏度均要高的多,对复杂和微量残留溶剂的分析能力有极大的提高,所以选择毛细管柱一般都能解决分离问题。其中柱口直径为0153mm的大口径毛细管柱因其柱容量大尤其应用广泛。姚倩、李章万、张

安捷伦A气相色谱仪作业指导书

XXXX 环境监测站 安捷伦7820A 气相色谱仪作业指导书 修改记录 1.目的 为了不断提高和保证全站监测工作质量,规范我站的安捷伦7820A 气相色谱仪操作规程,方便分析人员使用、维护仪器。 2.适用范围 此作业指导书适用于安捷伦7820A 气相色谱仪。 3.操作程序

3.1 开机: 3.1.1.打开气源(按相应的检测器所需气体,FID需要氮气、氢气和空气)。 3.1.2打开计算机,进入Windows界面。 3.1.3打开7820A GC电源开关。 3.1.4待仪器自检完毕,双击“联机”图标,进入化学工作站,化学工作站自动与7820A通讯,建立连接。 3.2 7820A配置编辑 3.2.1点击“配置”按钮。在“其他”项目中选择压力单位。 3.1.2柱参数设定点击“色谱柱”按钮,进入柱参数设定画面。点击前面的数字,对该柱的名称、长度、内径、膜厚、最高使用温度、最低使用温度和该柱的类型进行设置;点击该柱下拉式箭头选择连接的进样口,检测器及加热类型;用“↑”和“↓”在各柱之间进行切换。 3.1.3在“模块”项目中选择后进样口和后检测器尾吹气的种类。 4.在“ALS”项目中输入所用自动进样针的规格。 3.3 测试以及数据采集方法编辑: 3.3.1 开始编辑完整方法 从“文件”菜单中选择“新建”→“方法”→“确定”。

3.3.2填写自动进样器的参数: 点击“”,设置进样体积:0.2uL,溶剂A 清洗,进样前清洗4次,进样后清洗4次,体积为最大,溶剂B清洗,进样前清洗4次,进样后清洗4次,体积为最大,样品清洗2次,样品抽吸次数6次,驻留时间,进样前:0分钟,进样后:0分钟,推杆速度:快速,粘度延迟:0秒,采样深度:不启用,进样类型:标准 L1气隙 0.2uL。 注:上述设置是常用设置,对于不同性质的样品,需要对某些参数进行更改,比如对于粘度较大的样品,需要将进样后驻留时间设为3-5s,同时将粘度延迟设为3-5s 3.3.3填写进样口参数: 点击“前进样器”或“后进样器”,根据需要填写前进样口或后进样口参数。输入数值后,在各参数前面打钩。根据需要设置进样口温度、进样的模式(分流、不分流、脉冲分流和脉冲不分流,毛细管柱一般要分流,填充柱一般不分流)。载气节省一般要开启。

Agilent7890A气相色谱仪的标准操作规程(精)

Agilent 7890A气相色谱仪的标准操作规程 Ⅰ 目的:制定Agilent 7890A气相色谱仪使用操作规程,确保操作人员能正确规范地使用气相色谱仪。 Ⅱ 范围:适用于Agilent 7890A气相色谱仪的使用。 Ⅲ 规程: 一开机 1 打开氮气瓶总开关,调节输出气压为0.4~0.6M Pa;打开空气发生器,氢气发生器。 2 打开7890A色谱仪开关,待GC进入自检,自检完成后会提示“Power on Successful”。 3 开启计算机,进入Windows系统后,双击电脑桌面的(Instrument Online图标,进入GC化学工作站。 二采集数据方法编辑 1 编辑新方法 1.1 从“Method”菜单中选择“Edit Entire Method”,根据需要钩选项目,“Method Information”(方法信息),“Instrument/Acquisition”(仪器参数/数据采集条件),“Data Analysis”(数据分析条件),“Run Time Checklist”(运行时间顺序表),确定后单击“OK”。 1.2 出现“Method Commons”窗口,如有需要输入方法信息(方法用途等),单击“OK”。 1.3 进入“Select Injection Source/Location”(进样器设置),接受默认选项,单击“OK”。

1.4 进入“Agilent GC Method: Instrument 1”(方法参数设置)。 1.4.1 “Injector”参数设置。输入“Injection Volume”(进样体积),和“Wash and Pumps”(洗针程序,完成后单击“OK”。 1.4.2 “Inlet”参数设置。输入“Heater”(进样口温度;“Septum Purge Flow”(隔垫吹扫速度);拉下“Mode”菜单,选择分流模式或不分流模式或脉冲分流模式或脉冲不分流模式;如果选择分流或脉冲分流模式,输入“Split Ratio”(分流比)。完成后单击“OK”。 1.4.3 “CFT Setting”参数设置。选择“Control Mode”(恒流或恒压模式,如选择恒流模式,在“Value”输入柱流速。完成后单击“OK”。 1.4.4 “Oven”参数设置。选择“Oven Temp On”(使用柱温箱温度;输入恒温分析或者程序升温设置参数;如有需要,输入“Equilibration Time”(平衡时间,“Post Run Time”(后运行时间)和“Post Run”(后运行温度)。完成后单击“OK”。 1.4.5 “Detector”参数设置。钩选“Heater”(检测器温度,“H2 Flow”(氢气流速,“Air Flow”(空气流速,“Makeup Flow”(尾吹速度 N2,“Flame”(点火和“Electrometer”(静电计,并对前四个参数输入分析所要求的量值。完成后单击“OK”。 2 单个样品的方法信息编辑及样品运行 2.1 从“Run Control”菜单中选择“Sample Info”选项,输入操作者名称,在“Data File”-“Subdirectory”(子目录)输入保存文件夹名称,并选择“Manual”或者“Prefix/Counter”,并输入相应信息;在“Sample Parameters”中输入样品瓶位置,样品名称等信息。完成后单击“OK”。

色谱柱选择

氰基柱与C18柱都是以球形硅胶微粒(通过无孔硅胶聚集成)为基质,只不过氰基柱键合的有机分子中含有极性基团,吸附活性较空白硅胶低,常用于正相操作。氰基柱能与某些含有双键的化合物发生选择性相互作用,因而对双键异构体或含有不等量双键的环状化合物有更好的分离能力。所以在选择极性键合相的柱子中,氰基柱是首选。 氰基柱可用于非极性、弱极性和中等极性化合物分析,在反相模式下,其保留性弱于C18,但对强极性化合物的保留强于C18(C18基本不保留强极性化合物)。氰基柱还可用于正相模式。 所以C18与氰基柱能够分析的化合物有一定的重合,但是两者的选择性有很大不同。C18是目前适用范围最广的色谱柱,适用于非极性、弱极性和中等极性化合物分析,某些强极性化合物配合离子对流动相也可以用C18分析,C18为纯反相柱。通常来说,化合物在正辛醇-水中的分配系数有一定差异,C18就能很好的分离它们。氰基柱上有极性基团,所以它对化合物的极性相互作用的强弱是分离化合物的基础,一般,化合物上极性基团的种类、数量或位置有差异,往往就能在氰基柱上较好分离。 氨基和氰基柱的使用和保养 氰基柱的使用和保养 CN基柱作反相色谱,操作和维护和C18柱完全相同。CN柱用于反相条件时,CN键会水解,尤其是在pH1.5-7.0范围以外,在极端酸性和碱性条件下柱寿命会下降很快,如果在这个条件下使用,需要清洗一下,也需要用10倍柱体积溶液冲洗,如下:95%水/5%乙腈、THF 四氢呋喃、95%乙腈/5%水并保持95%乙腈/5%水继续冲洗,以低流速0.2-0.5mL/min过夜冲洗。在pH1.5-7.0条件时,也比较伤柱子,使用完以后要注意冲洗,可以参照上述方法,时间不需要那么长,可适当减少。柱子使用一定时间后,柱效下降,老化,也可如正相时清洗一下柱子恢复柱性能,清洗时用10倍柱体积的下列溶液冲洗:95%水/5%乙腈THF四氢呋喃95%乙腈/5%水再走流动相即可。 CN柱用于正相使用时没什么问题,当柱子使用一定时间后,柱效下降,柱子老化,可清洗一下恢复柱性能。清洗时用10倍柱体积的下列溶液冲洗:氯仿、异丙醇、二氯甲烷再走流动相即可。 如果在pH 2.0-5.0条件时用流动相平衡一下即可,这是最理想的pH范围。 CN柱子不使用时,可用异丙醇或正己烷保存,两端封好。流动相改变时要注意过渡,比如缓冲盐过渡到有机相时需要先用水冲洗再走有机相。

配置和维护安捷伦工作站计算机

配置和维护安捷伦化学工作站计算机适用于安捷伦化学工作站 B.02.01 版 简介2 配置中文版 Windows XP Professional SP2 以与安捷伦化学工作站B.02.01 或更高版本配合使用的步骤3 安装 Windows XP3 配置 Windows XP 设置3 使用安捷伦 Bootp 服务的系统安全设置21 其他修改(使用 Administrator 用户帐户执行)23 维护 PC 的文件系统23 扫描和修复 NTFS 卷23 整理 NTFS 卷中的碎片26 扫描病毒27 清除残留的临时文件28 执行备份30

配置和维护安捷伦化学工作站计算机 简介 简介 安捷伦提供的化学工作站 PC 软件包系统预装了 Windows XP Professional Service Pack 2,并对其进行了配置以实现最佳的化学工作站性能。非安捷伦 PC 软件包系统则需要进行一些手动配置更改以提供最佳的性能。 本文档的第一章“配置中文版 Windows XP Professional SP2 以与安捷伦化学工 作站 B.02.01 或更高版本配合使用的步骤”,识别并说明了配置非安捷伦 PC 软 件包系统所需的所有参数以及重要设置(例如 Internet 安全)。请按照文档中所 述的步骤进行操作。 第二章“维护 PC 的文件系统”,说明了如何维护计算机以使其性能保持最佳状 态。

配置和维护安捷伦化学工作站计算机 配置中文版 Windows XP Professional SP2 以与安捷伦化学工作站 B.02.01 或更高版本配合使用的步骤配置中文版 Windows XP Professional SP2 以与安捷伦化学工作站 B.02.01 或更高版本配合使用的步骤 安装 Windows XP 1通过恢复 CD 或 Windows XP Professional CD-ROM 来安装 Windows XP 。 在 设置 Windows XP 的过程中,需要提供计算机名、管理员密码和网络设置。 选择加入现有的域或以工作组模式设置系统。 2通过在“开始”/“运行”命令提示下键入“winver ”来查看 Windows 版本: 如果必要,请安装适用于 XP 的 Service Pack 2。 忽略此选项以存档当前文件并 重新启动系统。 3要使系统免受病毒侵害,请安装防病毒程序。 运行防病毒程序可能会影响计算 机的操作和性能。 安捷伦化学工作站已经过测试可以与 Symantec 的 Norton Antivirus 一起运行。 详细信息请参见第 27 页的“扫描病毒”。 配置 Windows XP 设置 必须将本文档中的某些更改用于化学工作站以使其在 Windows XP 系统上正确运 行。 某些更改将优化应用程序的性能。 其他更改将产生图形方面的或细微的影响。 注意安装适当的安全修补程序和漏洞补丁之前,请断开 PC 与 Internet 的连接。 强烈建议在连接到网络之前,安装安捷伦支持的最新的安全补丁和病毒定义。 注意为了表明各个设置的相对重要性,将每个项目分类如下: ?必须: 必须应用这些更改。 ?性能: 这些更改将提高系统性能。 ?可选: 大部分更改将影响该应用程序的图形显示。

安捷伦气相色谱仪操作步骤1046仪器

2 1046仪器(成品) 2.1开机 1)打开气源(氢气、氮气、空气),减压阀压力必须大于等于0.5。 2)打开仪器左下角的按钮(按下去)。 3)打开电脑,双击桌面上的仪器联机。 4)单击左下角的方法。 5)双击方法中的你要侧的样品的方法,醋酸仲丁酯。 6)等待就绪(按仪器上的状态键 status 观察)。 7)就绪之后就可以进样。 2.2进样 1)单击上边工具栏上的运行控制,再点击样品信息,弹出对话框,在操作者姓名后填上你的名字和下面样品名称处填上样品名字 2)用1ul的进样针在样品瓶里涮几次针。 3)抽取小于1ul大于你要进的体积然后把针头插在硅胶垫上(排除气泡)缓慢推到你要进的体积处。 4)拿下硅胶垫,把针竖直插到进样口里快速推进。 5)按仪器上的开始键(start),迅速拔出进样针。 6)等待弹出报告。 2.3 处理报告 1)关闭自动弹出的报告,单击左下角的数据分析。 2)单击积分和信号中间的校正,这时弹出校正表。 3)删除校正表里图谱上没有的峰。 4)单击最上边工具栏上的校正(c)里的添加峰。弹出一个对话框直接单击确定。 5)把校正表里的化合物名称填上,是什么就填上什么,不知道的填问号,然后填含量,响应因子和含量的关系:含量=响应因子乘以面积响应因子和面积都是已知的。 6)单击校正表中的确定,再单击校正和信号左边的积分,再单击积分下的最左边的图标一下。

7)单击预览,没有错误的话单击打印。关掉预览对话框单击运行和控制方法。 2.4 关机 双击关机方法,关闭对话框,关闭电脑,等待仪器检测器(Front Det)和进样口(Front Intet)温度都低于100℃时关闭仪器(按仪器左下角的按钮),关掉气源。 3.维护保养: 3.1 更换隔垫:用专用工具拧下进样口绿色螺丝,取出隔垫,放进新隔垫(小洞朝上),然后拧紧螺丝,大约1-2周换一次. 3.2 更换衬管:用专业工具拧开进样口黄色部位移开进样口取出衬管,更换新衬管(项圈离衬管口大约5mm),重新安装进样口。 3.3每天擦拭仪器表面灰尘。 4.问题及解决方法 4.1开机后仪器报警原因及处理办法: 一、气体压力不够,查看钢瓶压力 二、前进样口压力不够,漏气,拧紧前进样口或者换隔垫(视上次换隔垫时间自己掌握) 三、管线接头漏气,试漏液检漏,应定期检漏。 4.2 点火失败原因及处理办法: 一、气体压力关闭说明气体压力不够,查看钢瓶压力,管线是否漏气 二、气源正常情况下,关软件及仪器重新开机 三、以上都不行,视情况而定了 4.3 基线偏高原因及处理办法: 一、换气源情况下开机偏高,重换气源 二、补给阱过期,更换补给阱 4.4 保留时间偏差太大原因及处理办法: 一、进样不均匀、峰高波动太大导致保留时间偏移太多,根据峰高走势调整进样量 二、拖后太多,更换隔垫或衬管(视上次更换时间及进样次数而定) 三、

如何选择色谱柱

如何选择色谱柱,比较一下C-18及C-8柱的硅烷基质 C-18和C-8硅烷色谱柱是高效液相色谱(HPLC)中最常使用的色谱柱,而且,在美国市场上有多于100种C-18和C-8色谱柱出售。面对这么多可供选择的色谱柱,分析工作者很难从中选出适当的色谱柱来具体使用,同时更难选择出一根合适的替换柱。 对于非极性样品(如小分子芳烃)或弱极性样品(如对羟基苯甲酸酯),C-18和C-8色谱柱是最容易选择的。对于这类样品,色谱柱之间的主要差异在于保留因子(k);而在选择性方面却只有微小的差异。但对于极性和中等极性样品色谱柱的选择却相当困难。例如含氨基或酸性基团的药物化合物。分析工作者会发现极性样品在保留时间、选择性和峰形都有很大的差别。 色谱柱的选择性和峰形受到担体硅胶的影响远大于键合相的影响。另外,有研究报道在反相色谱中表面硅烷醇、硅酸及金属杂质的影响。在特殊情况下,选择性的差异可由填料制备时使用的键合过程决定的。 通常情况下,色谱工作者选择HPLC色谱柱是通过比较由色谱柱供应商所提供的填料介质的规格来决定的。这些规格内容包括:表面积、末端封尾、含碳量、颗粒形状、颗粒尺寸、孔径、孔容积、装填密度和键合度。含碳量和键合度仅由色谱制造商提供,没有这些规格使用者不可能计算出碳的克数,也不可能计算出一根色谱柱中键合相的微分子数。分析工作者可使用这两个数据来估计一根色谱柱的疏水性质。然而,即使制造商提供所有上述规格数据,使用者也不可能精确地预测出色谱柱对含有极性官能团的化合物的选择性。 由于色谱的保留时间是基于分析物和填充基质之间许多微妙的相互作用,我们建议使用混合物测试来比较填充基质的规格与性能。Engelhardt 和他的同伴回顾了硅烷反相色谱的特性,并且提出用溶解物试验来描述固定相的疏水性和亲硅基醇特性。另外有一些人也改进了测试条件和方法来解释那些色谱数据,但他们只测试了很少的商品色谱柱,并且在他们的测试混合物中没有羧酸。在本文中,我们使用了一个含有羧酸的测试混合物来收集了86根C-18和C-8硅烷色谱柱(见表1)的数据。我们将测试结果详细描述如下。表1:研究中所使用的色谱柱的生产商(略)。 在我们的比较中,我们使用了含有6种物质的测试混合物,此6种物质列于图1。每一种物质在测试混合物中都起特殊的作用。尿嘧啶是用于产生空体积。甲苯是测试色谱柱的疏水性。吡啶和N,N-二甲基苯胺是用来测试硅醇基对碱性物质的活性的碱性胺类物质。苯酚是一种弱酸,用于与吡啶联合起来确定活性担体硅的数量。4-正丁基苯甲酸是一种用于测试硅醇基对酸性物质的活性羧酸,此方面是色谱柱制造者开发碱性去活色谱柱来作胺类物质分析时经常忽略的。 我们使用的流动相是含有65%的乙腈和35%的浓度为0.05M的磷酸钾混合溶液,pH值为3.2。pH=3.2的缓冲溶液可使4-正丁基苯甲酸质子化,同时可提高吡啶和N,N-二甲基苯胺的保留时间的重现性。我们发现使用没有加缓冲溶液的流动相,如65%乙腈和35%水,即使我们使用同一瓶流动相,也无法得到重现性较好的保留时间和峰形。高离子强度的缓冲溶液,如本次测试所使用的0.05M的缓冲溶液,会抑制一些硅醇基的活性(2,5),但对于将胺从一些非碱性去活的反相色谱柱中洗脱下来,有一些抑制作用是必要的。 我们测试过另外两种缓冲溶液,但它们的作用均少于pH=3.2的0.05M磷酸钾溶液。0.01M 磷酸钾缓冲溶液在pH=3.2时,胺类化合物在有些色谱柱中产生前移峰。0.05M磷酸钾缓冲溶液在pH=7时,胺类物质产生的峰形比在pH=3.2时更好。吡啶和N,N-二甲基苯胺的pKa 均大约为5.2;因此,这些组分在pH=7时未质子化并且呈中性,同时并不与强酸性的硅醇基发生离子交换作用。 液相色谱柱原理

Agilent 7890B气相色谱仪

Agilent 7890B气相色谱仪 新增集成智能功能的Agilent 7890B 气相色谱仪依托安捷伦40多年的色谱经验。休眠/唤醒模式降低载气和能源消耗,7890B 和5977A MSD 的双向直接通讯保护了您的投资,将放空时间缩短高达40%,增强型早期维护反馈功能减少了不必要的停机。集成在安捷伦数据系统中的GC 计算器优化了方法,并且将计算值自动转移到方法编辑器。高级电子气路控制和数字电路为保留时间锁定精度和快速柱箱降温 设定了新的标准,助您事倍功半。微板流路控制技术(CFT)提供一系列工具,包括反吹、用于多检测器的分流器、实现更好分离的Dean Switch等,这些工具有助于缩短样品前处理的时间,增加了数据的可靠性。这些优质的设计和可靠性可使您的系统长期处于最优状态运行。内置的氢气安全功能和氦气保存模式帮助实验室在分析运行中节省更多经费。 成就您对价值的追寻,请访问:https://www.doczj.com/doc/da9909721.html,/chem/resolve 产品特点: OpenLAB气相色谱软件简化了方法设置和系统操作,无论是单一用户/单一仪器实验室,还是多仪器/多供应商实验室,都能最大限度缩短其满足实际分析需求的培训时间 惰性流路利用安捷伦的化学脱活技术和消耗品帮助您从进 样到检测获得更高的灵敏度

多模式进样口(MMI) 作为程序升温汽化进样器具备多种功能,如分流/不分流、程序升温和大体级进样 Agilent 7693 系列自动进样器(ALS)拥有可选的50 位或150 位样品瓶的容量和更强的样品前处理功能,具备双进样口同时进样的能力,可提供所有气相色谱自动进样器中最快的进样速度 微板流路控制技术(CFT) 通过反吹、Dean Switch和用于多检测器的分流器为您的色谱增加多维分离能力,可实现柱箱内的无泄漏连接 氦气保存模块在GC 和GC/MS系统待机时转换为替代载气,极大地降低了系统的氦气消耗 当方法转换到替代载气时,氢气感应模块帮助实验室解除顾虑 保留时间锁定软件您在不同的安捷伦气相色谱系统上获得的保留时间都具有极高的重现性,无论使用何种进样口和检测器,也无论是谁在操作或在什么地方操作 选配的条码阅读器将安捷伦色谱柱、衬管、其他信息、错误解除信息自动导入7890B气相色谱系统或数据系统,甚至是分析方法中。部件识别工具可快速识别部件及部件号,便于再次订购 低热容(LTM) 低热容模块通过对GC 和GC/MS 直接快速加热和冷却,为气相色谱提供了更快的分析速度和更高的

Agilent7890A5975C气相色谱质谱联用仪操作规程(精)

Agilent 7890 A/ 5975C气相色谱质谱联用仪操作规程 1.开机 1)打开载气钢瓶控制阀,设置分压阀压力至0.5Mpa。 2打开计算机,登录进入Windows XP系统,初次开机时使用5975C的小键盘LCP输入IP地址和子网掩码,并使用新地址重起,否则安装并运行Bootp Service。 3)依次打开7890AGC、5975MSD电源(若MSD真空腔内已无负压则应在打开MSD电源的同时用手向右侧推真空腔的侧板直至侧面板被紧固地吸牢),等待仪器自检完毕。 4)桌面双击GC-MS图标,进入MSD化学工作站 5)在上图仪器控制界面下,单击视图菜单,选择调谐及真空控制进入调谐与真空控制界面,在真空菜单中选择真空状态,观察真空泵运行状态,此仪器真空泵配置为分子涡轮泵,状态显示涡轮泵转速涡轮泵转速应很快达到100%,否则,说明系统有漏气,应检查侧板是否压正、放空阀是否拧紧、柱子是否接好。

2.调谐 调谐应在仪器至少开机2个小时后方可进行,若仪器长时间未开机为得到好的调谐结果将时间延长至4小时。 1)首先确认打印机已连好并处于联机状态。 2在操作系统桌面双击GC-MS图标进入工作站系统。 3)在上图仪器控制界面下,单击视图菜单,选择调谐及真空控制进入调谐与真空控制界面。 4单击调谐菜单,选择自动调谐调谐MSD,进行自动调谐,调谐结果自动打印。 5如果要手动保存或另存调谐参数,将调谐文件保存到atune.u中。 6然后点击视图然后选择仪器控制返回到仪器控制界面。 注意: 自动调谐文件名为ATUNE.U 标准谱图调谐文件名为STUNE.U 其余调谐方式有各自的文件名. 3.样品测定 3.1方法建立 1)7890A配置编辑 点击仪器菜单,选择编辑GC配置进入画面。在连接画面下,输入GC Name:GC 7890A;可在Notes处输入7890A的配置,写7890A GC with 5975C MSD。点击获得GC配置按钮获取7890A的配置。 2)柱模式设定

相关主题