当前位置:文档之家› Camfil(康斐尔)空气过滤器中文版资料

Camfil(康斐尔)空气过滤器中文版资料

Camfil(康斐尔)空气过滤器中文版资料
Camfil(康斐尔)空气过滤器中文版资料

Version

200306 Air Filters Datasheet

空气过滤器样本目录

请打开左侧 “书签”,选择您所需的空气过滤器。

clean air solutions

Camfil Farr China (Shanghai)

Rm 1403, Shanghaimart Tower, 2299 Yan An Road, Shanghai, 200336

Tel:021-********,Fax:021-********

康斐尔中国(上海)

中国上海,延安西路2299号,上海世贸大厦1403室,邮编 200336电话:021-********,传真:021-********

http: //https://www.doczj.com/doc/1f8992188.html,

http: //https://www.doczj.com/doc/1f8992188.html,

Product Version

30/30 CL2 -4" & 2" & 1" (G4)

200306

板式多褶预过滤器

Frame:Rigid high wet-strength beverage board. 外框:耐高湿型防水纸板

Media:Non-woven reinforced cotton&synthetic media 滤料:棉纤&化纤混合无纺滤料

Media support grid: welded steel wire, anti-corrosive.

焊接钢丝护网,表面防锈处理。

Efficiency: G4 (EN 779): 25%-30% ASHRAE 52/76过滤效率 > 95% @ (≥5um)

Fire retardant grade: UL-2 listed. (UL 900)

防火等级

Humidity:≤ 100% RH 耐湿性:

Recommended Max. Final Pressure drop: ≤ 225 Pa 建议最大允许终阻力

Applications: prefilters for commercial&industrial AHU.

主要应用: 商用和工业用通风空调系统的预过滤。

名义厚度名义尺寸 实际尺寸 (mm)过滤面积 风量 / 初阻力褶数 / 英尺

(英寸)

(英寸 ")

高宽厚

(m2) (m3/h / Pa)(1英尺=305mm)

30/30 CL2 24 x 24 x 459459495 2.661700 / 183400/ 6830/30 CL2 24 x 12 x 459428995 1.30 850 / 181700 / 6830/30 CL2 24 x 20 x 459449295 2.201420 / 182840 / 684“

30/30 CL2 20 x 20 x 449249295 1.821180 / 182360 / 6811

30/30 CL2 20 x 16 x 449239195 1.45 935 / 181870 / 6830/30 CL2 25 x 20 x 461949295 2.301480 / 182960 / 6830/30 CL2 25 x 25 x 461961995 2.901860 / 183720 / 6830/30 CL2 24 x 24 x 259459445 1.751700 / 203400 / 7030/30 CL2 24 x 12 x 2594289450.85 850 / 201700 / 7030/30 CL2 24 x 20 x 259449545 1.461420 / 202840 / 7030/30 CL2 24 x 18 x 259444545 1.311275 / 202550 / 7030/30 CL2 20 x 20 x 249549545 1.211180 / 202360 / 702”

30/30 CL2 20 x 18 x 249544545 1.091060 / 202120 / 7015

30/30 CL2 20 x 16 x 2495394450.97 935 / 201870 / 7030/30 CL2 20 x 12 x 2495289450.74 715 / 201430 / 7030/30 CL2 25 x 20 x 262249545 1.521480 / 202960 / 7030/30 CL2 25 x 18 x 262244545 1.371325 / 202650 / 7030/30 CL2 25 x 16 x 262239445 1.181180 / 202360 / 7030/30 CL2 24 x 24 x 1597597220.881190 / 202380 / 6330/30 CL2 24 x 12 x 1597292220.43 590 / 201190 / 6330/30 CL2 24 x 20 x 1597495220.74995 / 201990 / 631"

30/30 CL2 20 x 20 x 1495495220.60825 / 201650 / 6316

30/30 CL2 20 x 16 x 1495394220.48660 / 201325 / 6330/30 CL2 25 x 20 x 1622495220.761035 / 202070 / 6330/30 CL2 25 x 16 x 1622394

22

0.61825 / 201650 / 63

D

W

H

通风用化纤袋式粗效预过滤器

Hi-cap ,synthetic media bag prefilter

Applications: prefilter for commercial&industrial ventilation system, with stable performance.

Cleanroom MAU and AHU system Automotive industry Hotel and office building

主要应用: 商用及工业用通风空调系统的预过滤器,性能稳定。 洁净室新风空调系统。 汽车工业 酒店和写字楼

Model Width Height Depth Media area No. of pockets Airflow / pressure drop Efficiency 型 号

宽高

滤料面积袋数

EN779

(mm)

(mm)(mm)

(m 2)

(m 3)

(kg)

HF 80/25-66592592360 2.662550 / 303400 / 404250 / 55G30.05 2.2HF 80/25-56490592360 2.252100 / 302850 / 403550 / 55G30.05 1.9HF 80/25-36287592360 1.331250 / 301700 / 402100 / 55G30.03 1.3HF 80/25-55490490360 1.851750 / 302375 / 402950 / 55G30.05 1.6HF 90/35-66592592360 2.662550 / 453400 / 604250 / 80G40.05 2.2HF 90/35-56490592360 2.252100 / 452850 / 603550 / 80G40.05 1.9HF 90/35-36287592360 1.331250 / 451700 / 602100 / 80G40.03 1.3HF 90/35-55490490360 1.851750 / 452375 / 602950 / 80G40.05 1.6

Note: Pressure drop +/- 15%

Specification 性能说明Frame:Galvanised sheet metal, 20mm header frame Efficiency:

G3 (EN 779): Avg.arrestance 80%

外框镀锌钢板,20mm 厚法兰。

过滤效率

平均计重效率80%

G4 (EN 779): Avg.arrestance 90-95%

平均计重效率90-95%

Media:Synthetic fibre Temperature:

≤70o C 滤料合成纤维

连续运行温度

Humidity:

≤100% RH

耐湿性

Recommended final pressure drop: ≤250 Pa

建议最大终阻力

Camfil Farr China (Shanghai)

Shipping data 运输体积、重量(m 3/h & Pa)

不同风量 / 初阻力H

W

D

Product Version

Hi-Flo, -4050 (F5)

200306

玻璃纤维袋式过滤器

Frame:Galvanised sheet metal, 20 mm header frame.外框:镀锌钢板外框,20mm 厚法兰框。

Media:Melt-blown super fine Glass fibre, "V"-shape pockets 滤料:熔喷超细玻璃纤维滤料, “V" 形滤袋结构。Efficiency: F5 (EN 779): 40%-50% ASHRAE 52/76过滤效率

Fire retardant grade: UL-2 listed. (UL 900)

防火等级

Temperature:≤ 90o C 耐温性:Humidity:≤ 100% RH 耐湿性:

Max. Final Pressure drop: ≤ 600 Pa 最大允许终阻力

Applications: main filters for commercial&industrial AHU. prefilters for cleanroom MAU.

主要应用: 商用和工业用通风空调系统的主过滤器。 洁净室用通风空调系统的预过滤器。

Model

Width Height Depth Media pock-Airflow and pressure drop Effi. Shipping

宽高深area ets 不同风量 / 初阻力EN779data

(mm)

(mm)

(mm)

(m 2)

袋数 (m 3/h & Pa)

(m 3)

(kg)

3A-4050592592600 4.562500 / 353600 / 604250 / 85F50.051 1.53B-4050490592600 3.652000 / 352900 / 603550 / 85F50.051 1.33C-4050

287592600 2.231250 / 351800 / 602100 / 85F50.0250.9Hi-Flo 490x490-5x600-4050490490600 3.051750 / 352500 / 602950 / 85F50.051 1.1Hi-Flo 592x592-6x500-4050592592500 4.062500 / 403600 / 704250 / 95F50.051 1.5Hi-Flo 490x592-5x500-4050490592500 3.252000 / 402900 / 703550 / 95F50.051 1.3Hi-Flo 287x592-3x500-4050287592500 2.031250 / 401800 / 702100 / 95F50.0250.9Hi-Flo 490x490-5x500-4050490490500 2.751750 / 402500 / 702950 / 95F50.051 1.1Hi-Flo 592x592-10x600-40505925926007.3102500 / 303600 / 504250 / 60F50.051 2.9Hi-Flo 490x592- 8x600-4050490592600 5.982000 / 302900 / 503550 / 60F50.051 2.4Hi-Flo 287x592- 5x600-4050287592600 3.651250 / 301800 / 502100 / 60F50.025 1.5Hi-Flo 490x490- 8x600-4050

490

490

600

4.9

8

1750 / 30

2500 / 50

2950 / 60

F5

0.051

2.0

Note: Pressure drop +/- 15%

D

W

Product Version

Hi-Flo, -65 (F6)

200306

Frame:Galvanised sheet metal, 20 mm header frame.外框:镀锌钢板外框,20mm 厚法兰框。

Media:Melt-blown super fine Glass fibre, "V"-shape pockets 滤料:熔喷超细玻璃纤维滤料, “V" 形滤袋结构。Efficiency: F6 (EN 779): 60%-65% ASHRAE 52/76过滤效率

Fire retardant grade: UL-2 listed. (UL 900)

防火等级

Temperature:≤ 90o C 耐温性:Humidity:≤ 100% RH 耐湿性:

Max. Final Pressure drop: ≤ 600 Pa 最大允许终阻力

Applications: main filters for commercial&industrial AHU. prefilters for cleanroom MAU.

主要应用: 商用和工业用通风空调系统的主过滤器。 洁净室用通风空调系统的预过滤器。

Model

Width Height Depth Media pock-Airflow and pressure drop Effi. Shipping 宽高深area ets 不同风量 / 初阻力

EN779

data (mm)(mm)(mm)(m 2

)袋数 (m 3/h & Pa)

(m 3)(kg)

3M-65

5925926359.2122500 / 503600 / 754250 / 90F60.051 3.23N-654905926357.6102000 / 502900 / 753550 / 95F60.051 3.03O-65

287592635 4.661250 / 501800 / 752100 / 90F60.025 1.9Hi-Flo 490x490-10x635-65490490635 6.4101700 / 502500 / 752950 / 90F60.051 2.53XM-655925926357.8102500 / 453600 / 754250 / 95F60.051 3.03YM-65490592635 6.382000 / 452900 / 753550 / 100F60.051 2.53ZM-65

287592635 3.951250 / 451800 / 752100 / 95F60.025 2.0Hi-Flo 490x490-8x635-65490490635 5.281700 / 452500 / 752950 / 95F60.051 2.13P-65592592534 6.35102500 / 503600 / 754250 / 95F60.051 2.93Q-65490592534 5.182000 / 502900 / 753550 / 100F60.051 2.43R-65

287592534 3.251250 / 501800 / 752100 / 95F60.025 1.5Hi-Flo 490x490-8x534-65490490534 4.281700 / 502500 / 752950 / 95F60.051 2.03UF-65-66592592600 6.082500 / 503600 / 804250 / 100F60.051 2.93UF-65-56490592600 4.562000 / 502900 / 803500 / 105F60.051 2.43UF-65-36287592600 3.141250 / 501800 / 802100 / 100F60.025 1.53UF-65-55

490490600 3.861700 / 502500 / 802950 / 100F60.051 2.03A-65592592600 4.562500 / 553600 / 854250 / 110F60.051 1.63B-65490592600 3.652000 / 502900 / 803550 / 100F60.051 1.43C-65

287592600 2.231250 / 551800 / 802100 / 105F60.025 1.0Hi-Flo 490x490-5x600-65490490600 3.051700 / 552500 / 802950 / 105F60.051 1.23S-6559259291511.2102500 / 403600 / 654250 / 80F60.051 3.53T-654905929158.882000 / 402900 / 653550 / 80F60.051 3.13U-65

287592915 5.751250 / 401800 / 652100 / 75F60.036 2.1Hi-Flo 490x490-8x915-654904909157.381700 / 402500 / 652950 / 75F60.051 2.63TF-65-66592592380 5.5122500 / 653600 / 1004250 / 125F60.051 2.63TF-65-56490592380 4.6102000 / 602900 / 953550 / 125F60.051 2.23TF-65-36287592380 2.761250 / 651800 / 1002100 / 125F60.025 1.43TF-65-55

490

490

380

3.8

10

1700 / 65

2500 / 100

2950 / 125

F6

0.051

1.8

Note: Pressure drop +/- 15%

H D

D

W

H

D

W

Frame:Galvanised sheet metal, 20 mm header frame.外框:镀锌钢板外框,20mm 厚法兰框。

Media:Melt-blown super fine Glass fibre, "V"-shape pockets 滤料:熔喷超细玻璃纤维滤料, “V" 形滤袋结构。Efficiency: F7 (EN 779): 80%-90% ASHRAE 52/76过滤效率

Fire retardant grade: UL-2 listed. (UL 900)

防火等级

Temperature:≤ 90o C 耐温性:Humidity:≤ 100% RH 耐湿性:

Max. Final Pressure drop: ≤ 600 Pa 最大允许终阻力

Applications: main filters for commercial&industrial AHU, and for cleanroom MAU system.

主要应用: 商用,工业用,洁净室用通风空调系统的主过滤器。

Model

Width Height Depth Media pock-Airflow and pressure drop

Effi.

Shipping 宽高深area ets 不同风量 / 初阻力

EN779data

(mm)(mm)(mm)(m 2)袋数

(m 3/h & Pa)

(m 3)

(kg)

3M-855925926359.2122500/603600/1054250/125F70.051 2.93N-854905926357.6102000/602900/1053550/125F70.051 2.53O-85

287592635 4.661250/601800/1052100/125F70.025 1.7Hi-Flo 490x490-10x635-85490490635 6.4101700/602500/1052950/125F70.051 2.13XM-855925926357.8102500/653600/1104250/130F70.051 3.03YM-85490592635 6.382000/652900/1103550/130F70.051 2.53ZM-85

287592635 3.951250/651800/1102100/130F70.025 2.0Hi-Flo 490x490-8x635-85490490635 5.281700/652500/1102950/130F70.051 2.13P-85592592534 6.35102500/753600/1254250/150F70.051 2.63Q-85490592534 5.182000/752900/1253400/150F70.051 2.33R-85

287592534 3.251250/751800/1252100/150F70.025 1.6Hi-Flo 490x490-8x534-85490490534 4.281700/752500/1252950/150F70.051 1.93UF-85-66592592600 6.082500/853600/1304250/160F70.051 2.93UF-85-56490592600 4.562000/852900/1303400/170F70.051 2.43UF-85-36287592600 3.141250/851800/1302100/155F70.025 1.53UF-85-55

490490600 3.861700/852500/1302950/155F70.051 2.03S-8559259291511.2102500/453600/704250/85F70.051 2.93T-854905929158.882000/452900/703550/90F70.051 2.63U-85

287592915 5.751250/451800/702100/85F70.036 1.8Hi-Flo 490x490-8x915-854904909157.381700/452500/702950/85F70.051 2.23TF-85-66592592380 5.5122500/953600/1454250/175F70.051 2.33TF-85-56490592380 4.6102000/952900/1403550/175F70.051 2.13TF-85-36287592380 2.761250/951800/1452100/175F70.025 1.43TF-85-55

490

490

380

3.8

10

1700/95

2500/145

2950/175

F7

0.051

1.7

Note: Pressure drop +/- 15%

H

D

W

Frame:Galvanised sheet metal, 20 mm header frame.外框:镀锌钢板外框,20mm 厚法兰框。

Media:Melt-blown super fine Glass fibre, "V"-shape pockets 滤料:熔喷超细玻璃纤维滤料, “V" 形滤袋结构。Efficiency: F8/9 (EN 779): 90%-95% ASHRAE 52/76过滤效率

Fire retardant grade: UL-2 listed. (UL 900)

防火等级

Temperature:≤ 90o C 耐温性:Humidity:≤ 100% RH 耐湿性:

Max. Final Pressure drop: ≤ 600 Pa 最大允许终阻力

Applications: main filters for commercial&industrial AHU, and for cleanroom MAU system.

主要应用: 商用,工业用,洁净室用通风空调系统的主过滤器。

Model

Width Height Depth Media pock-Airflow and pressure drop

Effi. Shipping

宽高深area ets

不同风量 / 初阻力EN779data

(mm)(mm)(mm)(m 2)袋数 (m 3/h & Pa)

(m 3)

(kg)

3M-955925926359.2122500/953600/1454250/170F8/90.051 2.93N-954905926357.6102000/952900/1453550/170F8/90.051 2.53O-95

287592635 4.661250/951800/1452100/170F8/90.025 1.7Hi-Flo 490x490-10x635-95490490635 6.4101700/952500/1452950/170F8/90.051 2.13XM-955925926357.8102500/953600/1454250/175F8/90.051 3.03YM-95490592635 6.382000/952900/1453550/175F8/90.051 2.53ZM-95

287592635 3.951250/951800/1452100/175F8/90.025 2.0Hi-Flo 490x490-8x635-95490490635 5.281700/952500/1452950/175F8/90.051 2.13P-95592592534 6.35102500/903600/1404250/170F8/90.051 2.63Q-95490592534 5.182000/902900/1403400/170F8/90.051 2.33R-95

287592534 3.251250/901800/1402100/170F8/90.025 1.6Hi-Flo 490x490-8x534-95490490534 4.281700/902500/1402950/170F8/90.051 1.93UF-95-66592592600 6.082500/1053600/1654250/200F8/90.051 2.93UF-95-56490592600 4.562000/1052900/1653400/200F8/90.051 2.43UF-95-36287592600 3.141250/1051800/1652100/200F8/90.025 1.53UF-95-55

490490600 3.861700/1052500/1652950/200F8/90.051 2.03S-9559259291511.2102500/603600/904250/110F8/90.051 2.93T-954905929158.882000/602900/903400/110F8/90.051 2.63U-95

287592915 5.751250/601800/902100/110F8/90.036 1.8Hi-Flo 490x490-8x915-954904909157.381700/602500/902950/110F8/90.051 2.23TF-95-66592592380 5.5122500/1353600/2104250/255F8/90.051 2.33TF-95-56490592380 4.6102000/1302900/2003550/255F8/90.051 2.13TF-95-36287592380 2.761250/1401800/2102100/255F8/90.025 1.43TF-95-55

490

490

380

3.8

10

1700/135

2500/205

2950/255

F8/9

0.051

1.7

Note: Pressure drop +/- 15%

H

D

W

化纤袋式中效过滤器

S-Flo, synthetic media high efficiency bag filter.

Applications: Main filter for commercial&industrial ventilation system, with steady performance.

Cleanroom MAU and AHU system Automotive industry Hotel and office building 主要应用: 商用及工业用通风空调系统的主流预过滤器,性能稳定。 洁净室新、回风系统。 汽车工业 酒店和办公楼

Model Width Height Depth Media area No. of pockets Airflow / pressure drop Efficiency 型 号

宽高

滤料面积袋数

EN779

(mm)

(mm)(mm)

(m 2)

(m 3)

(kg)

S-Flo A5592592600 4.762550 / 403400 / 504250 / 70F50.05 2.4S-Flo B5490592600 3.952100 / 402850 / 503550 / 70F50.05 2.0S-Flo C5287592600 2.331250 / 401700 / 502100 / 70F50.03 1.5S-Flo A6592592600 4.762550 / 453400 / 554250 / 75F60.05 2.4S-Flo B6490592600 3.952100 / 452850 / 553550 / 75F60.05 2.0S-Flo C6287592600 1.331250 / 451700 / 552100 / 75F60.03 1.5S-Flo A7592592600 4.762550 / 523400 / 704250 / 85F70.05 2.4S-Flo B7490592600 3.952100 / 522850 / 703550 / 85F70.05 2.0S-Flo C7287592600 2.331250 / 521700 / 702100 / 85F70.03 1.5S-Flo UF7592592600 6.082550 / 453400 / 604250 / 75F70.05 2.8S-Flo UG7490592600 4.642100 / 452850 / 603550 / 75F70.05 2.4S-Flo UH7287592600 3.061250 / 451700 / 602100 / 75F70.03 1.6S-Flo UF8592592600 6.082550 / 603400 / 804250 / 100F80.05 2.8S-Flo UG8490592600 4.642100 / 602850 / 803550 / 100F80.05 2.4S-Flo UH8287592600 3.061250 / 601700 / 802100 / 100F80.03 1.6

Note: Pressure drop +/- 15%

Specification 性能说明Frame:Galvanised sheet metal, 20mm header frame Efficiency:

F5 (EN 779): 40-50% ASHRAE 52/76外框镀锌钢板,20mm 厚法兰。过滤效率

F6 (EN 779): 60-65% ASHRAE 52/76F7 (EN 779): 90% ASHRAE 52/76Media:Synthetic fibre F8 (EN 779): 95% ASHRAE 52/76滤料

合成纤维

Temperature:

≤70o C 连续运行温度

Pocket: "V" shape by Controlled Media Spacing.Humidity:

≤100% RH

滤袋结构:特殊定型技术使滤保持“V”形结构。

耐湿性

Recommended final pressure drop: ≤450 Pa

建议最大终阻力

Any size and pocket length are available. 可提供任意尺寸和袋长的S-Flo 过滤器。

Shipping data 运输体积、重量(m 3/h & Pa)

不同风量 / 初阻力W

L

D

通风用有隔板空气过滤器

Airopac 3CPM ,3CPMHF, 3CPMDHF -60 (F6),-90 (F7), -95 (F8)

Applications: Main filters for commercial&industrial AHU, and for cleanroom MAU system.

High relative humidity ventilation systems. Variable air volume(VAV) ventilation systems. Ventilation systems with limited installation space. Ventilation systems of high fire-proof requirement. Ventilation systems of high running temperature.

主要应用: 洁净室用,商用及工业用通风空调系统的主过滤器。 高湿度的通风空调系统。 变风量通风空调系统。

安装空间紧张的通风空调系统。

防火要求高或通风温度较高的通风空调系统。

Caution: the pleats and separators should stand vertical ! 使用时,滤褶和隔板应于垂直方向 !

Model Width Height Depth Media Airflow and pressure drop Efficiency 型 号

宽高厚area

不同风量 / 初阻力

效率等级(mm)

(mm)

(mm)

(m 2) (m 3/h & Pa)

EN779

(m 3)

(kg)

box type(箱式)

3CPM-242412-6061061029211.72500/703600/1004500/125F60.124 6.93CPM-202412-605086102929.62000/752900/1053600/130F60.124 6.23CPM-122412-60305610292 5.81250/751800/1052100/130F60.062 4.53CPM-242412-9061061029211.72500/853600/1254500/155F70.124 6.93CPM-202412-905086102929.62000/902900/1303600/160F70.124 6.23CPM-122412-90

305

610

292

5.8

1250/90

1800/1302100/160F70.062 4.53CPM-242412-9561061029211.72500/953600/1354500/165F80.124 6.93CPM-202412-955086102929.62000/1002900/1403600/170F80.124 6.23CPM-122412-95305610292 5.81250/1001800/1402100/170F80.062 4.5with header frame(进风面带法兰) SIZE:17.5mm(W)×20mm(D)3CPMHF-242412-605925922929.82500/803600/1154500/140F60.1248.83CPMHF-202412-604905922927.92000/852900/1203600/145F60.1248.13CPMHF-122412-60287592292 4.41250/851800/1202100/145

F60.062 5.53CPMHF-242412-905925922929.82500/1053600/1504500/185F70.1248.83CPMHF-202412-904905922927.92000/1102900/1553600/190F70.1248.13CPMHF-122412-90

287

592

292

4.4

1250/1101800/1552100/190

F70.062 5.53CPMHF-242412-955925922929.82500/1153600/1654500/205F80.1248.83CPMHF-202412-954905922927.92000/1202900/1703600/210F80.1248.13CPMHF-122412-95287592292 4.41250/1201800/1702100/210F80.062 5.5with double head frame(双法兰) SIZE:17.5mm(W)×20mm(D)3CPMDHF-242412-605925922929.82500/803600/1154500/140F60.1249.43CPMDHF-202412-604905922927.92000/852900/1203600/145F60.1248.53CPMDHF-122412-60287592292 4.41250/851800/1202100/145

F60.062 6.13CPMDHF-242412-905925922929.82500/1053600/1504500/185F70.1249.43CPMDHF-202412-904905922927.92000/1102900/1553600/190F70.1248.53CPMDHF-122412-90287592292 4.41250/1101800/1552100/190F70.062 6.1Shipping data 运输体积、重量W

D

Specification性能说明

Frame:Galvanised sheet metal Efficiency:F6 (EN 779): 60-65% ASHRAE 52/76外框镀锌钢板过滤效率F7 (EN 779): 90% ASHRAE 52/76 Separators:Aluminium F8 (EN 779): 95% ASHRAE 52/76

滤料分隔铝箔

Media:Wet-laid glass fibre Temperature:≤90o C

滤料抗水型玻璃纤维滤纸连续运行温度

Sealant material:Glass fiber.Humidity:≤100% RH

密封材料:玻璃纤维。耐湿性

Fire retardant: UL-900 Class 1Recommended final pressure drop: ≤450 Pa

防火认证:UL-1 防火等级。建议最大终阻力

Camfil Farr China (Shanghai)

Rm 1403, Shanghaimart Tower, 2299 Yan An Road, Shanghai, 200336

Tel:021-********,Fax:021-********

Opakfil -CC -60(F6), -90(F7), -95(F8)

200306

Applications: main filters for commercial&industrial AHU,

and for cleanroom MAU system.

High relative humidity ventilation systems. Variable air volume(VAV) ventilation systems. Ventilation systems with limited installation space.

主要应用: 洁净室用,商用及工业用通风空调系统的主过滤器。 高湿度的通风空调系统。 变风量通风空调系统。

安装空间紧张的通风空调系统。

Model

Width Height Depth Media Airflow and pressure drop Efficiency Shipping

型 号宽高厚area 不同风量 / 初阻力EN779data

(mm)

(mm)

(mm)

(m 2)

(m 3/h & Pa)

(m 3)

(kg)

3OPCCHF-242412-60

59559229014.32500 / 403600 / 804500 / 120F60.108 5.03OPCCHF-242012-6059549029011.32000 / 402900 / 803600 / 120F60.090 4.03OPCCHF-241212-60595287290 6.81250 / 451800 / 852100 / 130F60.054 3.03OPCCHF-242412-9059559229014.32500 / 603600 / 1004500 / 140F70.108 5.03OPCCHF-242012-9059549029011.32000 / 602900 / 1003600 / 140F70.090 4.03OPCCHF-241212-90595287290 6.81250 / 651800 / 1052100 / 150F70.054 3.03OPCCHF-242412-9559559229014.32500 / 753600 / 1254500 / 165F80.108 5.03OPCCHF-242012-9559549029011.32000 / 802900 / 1303600 / 170F80.090 4.03OPCCHF-241212-95

595

287

290

6.8

1250 / 801800 / 1352100 / 180

F8

0.054

3.0

Note: Pressure drop +/- 15%

Specification 性能说明Frame:Polypropylene Efficiency:F6 (EN 779): 60-65% ASHRAE 52/76外框

聚丙烯过滤效率F7 (EN 779): 90% ASHRAE 52/76Separators:Hot melt F8 (EN 779): 95% ASHRAE 52/76滤料分隔热熔胶

Temperature:

≤70o C Media:Wet-laid glass fibre 连续运行温度

滤料抗水型玻璃纤维滤纸Humidity:

≤100% RH

Sealant:Polyurethane 耐湿性

密封胶

聚氨酯

Recommended final pressure drop: ≤600 Pa

建议最大终阻力

W

H D

W

H

D W H D

Opakfil G 3OPGHF -60(F6), -90(F7), -95(F8), -98(F9)

200306

Applications: main filters for commercial&industrial AHU,

and for cleanroom MAU system.

High relative humidity ventilation systems. Variable air volume(VAV) ventilation systems. Ventilation systems with limited installation space.

主要应用: 洁净室用,商用及工业用通风空调系统的主过滤器。 高湿度的通风空调系统。 变风量通风空调系统。

安装空间紧张的通风空调系统。

Model Width Height Depth Media Airflow and pressure drop Efficiency Shipping

型 号宽高厚area 不同风量 / 初阻力EN779data

(mm)

(mm)

(mm)

(m 2) (m 3/h & Pa)

(m 3)

(kg)

3OPGHF-242412-60

59559229019.02500 / 353600 / 704500 / 105F60.108 5.03OPGHF-242012-6059549029015.02000 / 352900 / 703600 / 110F60.090 4.03OPGHF-241212-605952872909.01250 / 401800 / 752100 / 115F60.054 3.03OPGHF-242412-9059559229019.02500 / 503600 / 854500 / 120F70.108 5.03OPGHF-242012-9059549029015.02000 / 502900 / 903600 / 125F70.090 4.03OPGHF-241212-905952872909.01250 / 501800 / 902100 / 130F70.054 3.03OPGHF-242412-9559559229019.02500 / 603600 / 1004500 / 140F80.108 5.03OPGHF-242012-9559549029015.02000 / 652900 / 1053600 / 145F80.090 4.03OPGHF-241212-955952872909.01250 / 651800 / 1102100 / 150F80.054 3.03OPGHF-242412-9859559229019.02500 / 803600 / 1354500 / 185F90.108 5.03OPGHF-242012-9859549029015.02000 / 852900 / 1403600 / 190F90.090 4.03OPGHF-241212-98

595

287

290

9.0

1250 / 851800 / 1452100 / 195

F9

0.054

3.0

Note: Pressure drop +/- 15%

Specification 性能说明Frame:Polypropylene Efficiency:F6 (EN 779): 60-65% ASHRAE 52/76外框

聚丙烯过滤效率

F7 (EN 779): 90% ASHRAE 52/76Separators:Hot melt F8 (EN 779): 95% ASHRAE 52/76滤料分隔热熔胶

F9 (EN 779): 98% ASHRAE 52/76Media:Wet-laid glass fibre Temperature:

≤70o C 滤料抗水型玻璃纤维滤纸连续运行温度

Sealant:Polyurethane Humidity:

≤100% RH

密封胶

聚氨酯

耐湿性

Recommended final pressure drop: ≤600 Pa

建议最大终阻力

W

H D

W

H

D W H D

Opakfil G 7OPGHF MICRETAIN(H10)

200306

Applications: final filters for cleanroom AHU.

主要应用: 洁净室通风空调系统的末级过滤器。

Model

Width

Height Depth Media Airflow and pressure drop Efficiency Shipping

型 号宽高厚area 不同风量 / 初阻力EN 1822data

(mm)

(mm)

(mm)

(m 2)

(m 3/h & Pa)

(m 3)

(kg)

Micretain 7OPGHF-24241259559229019.02500 / 1603400 / 2304000 / 270H100.108 5.0Micretain 7OPGHF-24201259549029015.01900 / 1602650 / 2303100 / 270H100.090 4.0Micretain 7OPGHF-2412125952872909.01050 / 1601700 / 2302100 / 270H100.054 3.0

Note: Pressure drop +/- 15%

Specification 性能说明Frame: Polypropylene Efficiency:H10(EN 1822): ≥85% at MPPS 外框 聚丙烯

过滤效率Separators: Hot melt Temperature:

≤70o C 滤料分隔 热熔胶

连续运行温度

Media: Wet-laid glass fibre Humidity:

≤100% RH

滤料 抗水型玻璃纤维滤纸耐湿性

Sealant: Polyurethane Recommended final pressure drop: ≤600 Pa

密封胶 聚氨酯

建议最大终阻力

W

H D

W

H

D W H D

Opakfil G 1OPGHF Absolute (H13)

200306

Applications: final filters for cleanroom AHU,

direct to reach air cleanliness CL-10K/100K.

主要应用: 洁净室通风空调系统的最末级过滤器,

送风可直接满足万级/十万级空气洁净要求。

Model Width Height Depth Media Airflow and pressure drop Efficiency Shipping

型 号宽高厚area 不同风量 / 初阻力EN 1822data

(mm)

(mm)

(mm)

(m 2)

(m 3/h & Pa)

(m 3)

(kg)

Absolute 1OPGHF-24241259559229028.02500 / 2003000 / 2503400 / 285H130.10812.0Absolute 1OPGHF-24121259528729013.01050 / 2001450 / 2501650 / 285H130.0547.0

Note: Pressure drop +/- 15%

Specification 性能说明Frame: Polypropylene Efficiency:H13(EN 1822): ≥99.95% at MPPS 外框 聚丙烯过滤效率 ≥99.99% at 0.3um

Separators: Hot melt Each filter is individually tested 滤料分隔 热熔胶

出厂前逐台激光计数扫描检测。

Media: Wet-laid glass fibre Temperature:

≤70o C 滤料 抗水型玻璃纤维滤纸连续运行温度

Sealant: Polyurethane Humidity:

≤100% RH

密封胶 聚氨酯

耐湿性

Gasket: Endless polyurethane, back side of header frame. Recommended final pressure drop: ≤600 Pa

密封垫 注塑成型无接缝的聚氨酯,法兰背风面。

建议最大终阻力

W

H D

W

H

D W H D

Product

Airopac 3GGM -60(F6), -90(F7), -95(F8)Version

紧凑型无隔板通风用空气过滤器 (箱式)

200306

Applications: main filters for commercial&industrial AHU,

and for cleanroom MAU system.

High relative humidity ventilation systems. Variable air volume(VAV) ventilation systems. Ventilation systems with limited installation space.

主要应用: 洁净室用,商用及工业用通风空调系统的主过滤器。 高湿度的通风空调系统。 变风量通风空调系统。

安装空间紧张的通风空调系统。

Model Width Height Depth Media Airflow and pressure drop

Effi.Shipping 型 号

宽高厚area 不同风量 / 初阻力EN779data

(mm)

(mm)

(mm)

(m 2)

(m 3/h & Pa)

(m 3)

(kg)

3GGM-24246-6061061015012.32550 / 453400 / 704250 / 95F60.077 6.83GGM-20246-605086101509.62100 / 452850 / 703550 / 95F60.077 5.73GGM-12246-60305610150 6.11250 / 451700 / 702100 / 95F60.039 4.03GGM-20206-605085081507.91750 / 452375 / 702950 / 95F60.077 5.03GGM-242412-6061061029212.32550 / 453400 / 704250 / 95F60.1249.63GGM-202412-605086102929.62100 / 452850 / 703550 / 95F60.1248.33GGM-122412-60305610292 6.11250 / 451700 / 702100 / 95F60.062 5.43GGM-202012-605085082927.91750 / 452375 / 702950 / 95F60.1247.33GGM-24246-9061061015012.32550 / 653400 / 1004250 / 125F70.077 6.83GGM-20246-905086101509.62100 / 702850 / 1053550 / 130F70.077 5.73GGM-12246-90305610150 6.11250 / 701700 / 1052100 / 130F70.039 4.03GGM-20206-905085081507.91750 / 702375 / 1052950 / 130F70.077 5.03GGM-242412-9061061029212.32550 / 653400 / 1004250 / 125F70.1249.63GGM-202412-905086102929.62100 / 702850 / 1053550 / 130F70.1248.33GGM-122412-90305610292 6.11250 / 701700 / 1052100 / 130F70.062 5.43GGM-202012-905085082927.91750 / 702375 / 1052950 / 130F70.1247.33GGM-24246-9561061015012.32550 / 903400 / 1304250 / 170F80.077 6.83GGM-20246-955086101509.62100 / 902850 / 1353550 / 170F80.077 5.73GGM-12246-95305610150 6.11250 / 901700 / 1352100 / 170F80.039 4.03GGM-20206-955085081507.91750 / 902375 / 1352950 / 170F80.077 5.03GGM-242412-9561061029212.32550 / 903400 / 1304250 / 170F80.1249.63GGM-202412-955086102929.62100 / 902850 / 1353550 / 170F80.1248.33GGM-122412-95305610292 6.11250 / 901700 / 1352100 / 170F80.062 5.43GGM-202012-95

508

508

292

7.9

1750 / 90

2375 / 135

2950 / 170

F8

0.124

7.3

Note: Pressure drop +/- 15%

Specification 性能说明

Frame: Galvanized steel Efficiency:F6 (EN 779): 60-65% ASHRAE 52/76外框 镀锌钢板过滤效率F7 (EN 779): 90% ASHRAE 52/76Separators: Hot melt

F8 (EN 779): 95% ASHRAE 52/76滤料分隔 热熔胶

Temperature:

≤70o C Media: Wet-laid glass fibre 连续运行温度

滤料 抗水型玻璃纤维滤纸Humidity:

≤100% RH

Sealant: Polyurethane 耐湿性

密封胶 聚氨酯

Recommended final pressure drop: ≤600 Pa

建议最大终阻力

H D

H

D

H D 可提供任意非标尺寸!

W D

Product

Airopac 3GGMHF -60(F6), -90(F7), -95(F8)Version

紧凑型无隔板通风用空气过滤器 (带法兰框)

200306

Applications: main filters for commercial&industrial AHU, and for cleanroom MAU system.

High relative humidity ventilation systems. Variable air volume(VAV) ventilation systems. Ventilation systems with limited installation space.

主要应用: 洁净室用,商用及工业用通风空调系统的主过滤器。 高湿度的通风空调系统。 变风量通风空调系统。

安装空间紧张的通风空调系统。

Model Width Height Depth Media Airflow and pressure drop

Effi.Shipping 型 号宽高厚area 不同风量 / 初阻力EN779data

(mm)

(mm)

(mm)

(m 2)

(m 3/h & Pa)

(m 3)

(kg)

3GGMHF-24245-6059259213510.32550 / 553400 / 904250 / 130F60.077 6.83GGMHF-20245-604905921358.32100 / 602850 / 953550 / 130F60.077 5.73GGMHF-12245-60287592135 4.51250 / 651700 / 1052100 / 135F60.039 3.83GGMHF-20205-60490490135 6.81750 / 602375 / 952950 / 130F60.077 5.03GGMHF-24245-9059259213510.32550 / 853400 / 1254250 / 160F70.077 6.83GGMHF-20245-904905921358.32100 / 902850 / 1353550 / 165F70.077 5.73GGMHF-12245-90287592135 4.51250 / 1001700 / 1502100 / 185F70.039 3.83GGMHF-20205-90490490135 6.81750 / 902375 / 1352950 / 165F70.077 5.03GGMHF-24245-9559259213510.32550 / 1103400 / 1654250 / 215F80.077 6.83GGMHF-20245-954905921358.32100 / 1152850 / 1703550 / 220F80.077 5.73GGMHF-12245-95287592135 4.51250 / 1301700 / 2002100 / 250F80.039 3.83GGMHF-20205-95

490

490

135

6.8

1750 / 115

2375 / 170

2950 / 220

F8

0.077

5.0

Note: Pressure drop +/- 15%

Specification 性能说明

Frame: Galvanized steel Efficiency:F6 (EN 779): 60-65% ASHRAE 52/76外框 镀锌钢板过滤效率F7 (EN 779): 90% ASHRAE 52/76Separators: Hot melt

F8 (EN 779): 95% ASHRAE 52/76滤料分隔 热熔胶

Temperature:

≤70o C Media: Wet-laid glass fibre 连续运行温度

滤料 抗水型玻璃纤维滤纸Humidity:

≤100% RH

Sealant: Polyurethane 耐湿性

密封胶 聚氨酯

Recommended final pressure drop: ≤600 Pa

建议最大终阻力

W

D

可提供任意非标尺寸!

Product

Sofilair Absolute/Micretain

Version

大风量高效过滤器

200306

Applications: final filters for cleanroom AHU,

direct to reach air cleanliness CL-10K/100K. Supply air duct system for local clean zones. Supply air duct system for local clean zones.

Exhaust duct system against hazardous particles. Compact air cleaning equipments.

主要应用: 洁净室通风空调系统的最末级过滤器,

送风可直接满足万级/十万级空气洁净要求。 局部洁净区的送风管道系统。 含危险性污染物的排风系统。 结构紧凑的空气净化设备。

Article Model Width Height Depth Media Airflow and DP Efficiency Shipping number

宽高厚area 不同风量 / 初阻力EN779data

(mm)(mm)(mm)(m 2) (m 3/h & Pa)

(m 3

)

(kg)

170 0001Sofilair Absolute 1560.02610610292403000 / 1754000 / 250H130.10823.0

170 0002Sofilair Absolute 1560.01610610292332550 / 1803400 / 250H130.09022.0170 0003Sofilair Absolute 1565.01305610292161275 / 1851700 / 250H130.05413.0170 0004Sofilair Absolute 1567.01595595292382400 / 1803200 / 250H130.09022.0170 0005 Sofilair Absolute 1568.01 289 595 292 16 975 / 185 1300 / 250 H13 0.054 13.0170 0006Sofilair Micretain 1570.01610610292353750 / 1555000 / 250H110.10823.0170 0007Sofilair Micretain 1573.02610610292213000 / 1604000 / 250H110.09021.0170 0008Sofilair Micretain 1575.02305610292141500 / 1652000 / 250H110.05413.0170 0009Sofilair Micretain 1577.01595595292383150 / 1604200 / 250H110.09022.0170 0010Sofilair Micretain 1578.01289595292161250 / 1651700 / 250H110.05413.0170 0011Sofilair HEPA 1560.02.06610610292402250 / 1803000 / 250H140.10823.0170 0013Sofilair HEPA 1565.01.02305610292161125 / 1851500 / 250H140.09013.0170 0016Sofilair HEPA 1567.01.06595595292382250 / 1803000 / 250H140.10822.0170 0018Sofilair HEPA 1568.01.0628959529216 900 / 1851200 / 250H140.09013.0170 0016Sofilair HEPA 1560.02.99610610292402550 / 1803400 / 250H140.10822.0170 0018

Sofilair HEPA 1565.01.99

305

610

292

16

1275 / 185

1700 / 250

H14

0.090

13.0

Specification 性能说明Frame:Galvanised sheet metal with Efficiency:H13 (EN 1822) ≥ 99.95% at MPPS 外框retractable handle

过滤效率

H11 (EN 1822) ≥ 95% at MPPS 镀锌钢板,带可伸缩安装把手。

H14 (EN 1822) ≥ 99.995% at MPPS Separators:Hot melt Each filter is individually tested

滤料分隔热熔胶出厂前逐台激光计数扫描检测。Media:Glass fibre MPPS=最易穿透粒径

滤料玻璃纤维滤纸

Temperature:≤70o

C

Gasket:Polyurethane, endless

连续运行温度

密封垫注塑成型无接缝的聚氨酯Humidity:

≤100% RH

Sealant:Polyurethane 耐湿性

密封胶

聚氨酯

Recommended final pressure drop: ≤600 Pa

建议最大终阻力

D

新型化学气体&灰尘污染物复合过滤器

Version

Citycarb, one-step particle and carbon filter

200306

Applications: Ideal filter for luxury and healthy commercial AHU system. Ventilation system with limited installation space, used to remove both particle and low concentration gas pollutants. Airport

High level hotel and office building.

Museum and library supply AHU systems.

Ideal choice for upgrading existing AHU system.

主要应用: 高档健康商用空调系统的理想过滤器。

安装空间紧张又需要同时过滤灰尘和低浓度气体污染物的 通风空调系统。 机场

高档酒店和写字楼

博物馆、图书馆送风空调系统。

改进现有舒适性空调系统过滤功能的理想选择。

Model Width Height Depth Media Airflow and pressure drop Efficiency Shipping data

型 号宽高厚area 额定风量 / 初阻力EN779运输体积、重量

(mm)

(mm)

(mm)

(m 2)

(m 3)

(kg)

OPKCC-242412-85-01 PU

5925922928.0F70.1110.8OPKCC-242012-85-01 PU 592490292 6.6F70.119.2OPKCC-241212-85-01 PU

592

287

292

3.5

F7

0.06

5.4

Note: Pressure drop +/- 10%

Specification 性能说明Frame:Polystyrene Efficiency:F7 (EN 779): 90% ASHRAE 52/75外框

聚苯乙烯灰尘过滤效率Separators:Hot melt Recommended temp. range:0~40 ℃

滤料分隔热熔胶

建议运行温度范围Gasket:Polyurethane, endless Recommended RH:≤70% RH

密封垫一体注塑聚氨酯

建议使用相对湿度:Sealant:Non-outgassing Polyurethane.Recommended final pressure drop: ≤450 Pa

密封胶:无挥发性的聚氨酯。

建议最大终阻力Media:Multilayer carbon media to trap particles and gases.

滤料

多层复合合成纤维+活性炭滤料能同时去除灰尘和气体污染物。

Optional media of impregnated carbon for removing acid gases. 浸渍型除酸性气体活性炭供选择,用于特殊要求的通风空调系统。

3400 / 1202800 / 1201500 / 120

(m 3/h & Pa)

W

L

D

筒式组合化学过滤器

Camcarb ,chemical filter

Applications: Main chemical filters for most commercial&indus- trial ventilation system, with high performance, easy maintenance and raplacement. Microelectronics. Museum, etc.

主要应用: 商用及工业用通风空调系统的主流化学过滤器, 性能卓越,安装维护方便快捷。 电子工厂 博物馆

Model C. thichness C. volume C. type Shipping data

型 号

炭层厚度炭体积炭种类

运输体积、重量(mm)

(m3)

(m 3)

(kg)

Camcarb Cylinders 活性炭滤筒 (***)

Cylinder 260026 4.3CM05 / CM070.01 4.0Cylinder 3500

26

5.7

CM05 / CM07

0.02

5.2

Model 型 号

(m 3)

(kg)

Cylinder Mounting Frames 活性炭滤筒安装框架 (***)

Frame G80.02 3.0Frame G160.04 4.8Frame G8 SS 0.02 4.0Frame G16 SS

0.04

5.0

Specification 性能说明

*Many types of activated pelletised carbon available for removing various kinds of gases. eg. VOCs, bases, acids, formaldehyde, mercury vapour, radioactive gas, etc.*能根据实际需要提供多种特制柱状活性炭材料。请和我们联系。

如,挥发性有机化合物,碱性、酸性气体,甲醛,汞蒸气,放射性气体等。** Contact time for specific applications shall be advised by Camfil Farr engineers.** 具体使用场合的气流与活性炭的滞留时间请咨询康斐尔公司工程师。***Galvanized steel version or stainless steel version available on request ***金属材料可根据具体要求采用镀锌钢板或不锈钢。

125 / 40

Size 尺寸

Dia.直径×L 长(mm)

Air flow / Pressure drop 风量 / 阻力m 3/h / Pa (**)

90 / 40Overall Size 外形尺寸

W 宽×H 高×D 深(mm)

?145×455?145×605

610 x 305 x 70610 x 610 x 70610 x 305 x 70610 x 610 x 70

16816

Shipping data 运输体积、重量Number of slots for cylinders

活性炭滤筒安装数量

8

过滤器安全更换与防护用箱体

Camsafe, Safe change filter housing

Applications: Filter housing used to separate radioactive,

toxic or biological particles and gases and provide maximum safety for the operator Hospital isolation wards Chemical industry

Pharmaceutical industry Laboratory

主要应用: 过滤器安装箱体,用于隔离放射性、有毒和生化危险性灰 尘及气体,给过滤器更换人员提供最大程度的安全防护。 如:医院隔离病房 化工厂 制药厂 实验室

Model Weight Volume 型 号

重量体积Kg

m

3

碳钢喷涂型 painted type

Camsafe 1000, painted 440.35Camsafe P1/1000, painted

690.55Camsafe P2/1000, painted 890.70不锈钢型 stainless steel type Camsafe 1000, 1.4301440.35Camsafe P1/1000, 1.4301690.55Camsafe P2/1000, 1.4301

89

0.70

*incl. Male thread hand knobs +90mm. Allow access of approximately 1m to change the filter.*90mm 的紧固件尺寸,另外还需在进深方向留1m 的过滤器更换空间。

Specification 性能说明Air flow rate:2000~24000 m 3/h (with housings jointed together)处理风量 (通过箱体并联安装)

Tightness Class B @ 5000Pa (EN1886), sealing tested as per DIN 1946, Part 4.

气密性5000Pa 耐压下强度和气密性测试,达到Class B(EN1886), 测试标准德国DIN 1946。Advantages:Contact free filter change--Bag in and Bag out 优点:

免接触更换过滤器--袋进袋出

Accessories: Safe change bags, manometers and material for the flanged joints supplied on request.附件:

过滤器安全更换塑料袋,压差计,法兰连接用材料等。

Detail brochure is available from the local Camfil Farr Sales Office. 详细说明请从当地的康斐尔公司销售处索取。

730×1020×725(+90*)

Size 外形尺寸W 宽×H 高×D 深(mm)

730×535×725(+90*)730×790×725(+90*)

730×1020×725(+90*)730×535×725(+90*)prefiler Size 一级过滤器尺寸

W 宽×H 高×D 深(mm)730×790×725(+90*)610×610×292-610×610×47610×610×292

-610×610×292

610×610×47610×610×292

2nd prefiler Size 二级过滤器尺寸

W 宽×H 高×D 深(mm)

610×610×292610×610×292610×610×292610×610×292D

中效空气过滤器的全方位介绍 )

中效空气过滤器的全方位介绍 生活中常常会听到中效空气过滤器,那么什么是中效空气过滤器呢?顾名思义,中效空气过滤器也是空气过滤器的一种,山东武城欣琪净化设备有限公司在这里让您全方位了解这个产品。山东武城欣琪净化设备有限公司是主要生产销售:过滤器,深圳过滤器,空气过滤器,空气过滤网,初效过滤器,初效尼龙网过滤器,初效空气过滤器,中效过滤器,中效空气过滤器,高效过滤器,高效空气过滤器,铝网过滤器,初效活性碳过滤器,耐高温初效过滤器,袋式过滤器,箱式过滤器,FFU空气过滤单元,空气净化设备等的专业厂家。 中效过滤器,由人造纤维及镀锌铁所组合而成。有各种效率可供选择,包括 40-45% , 60-65% , 80-85% , 90-95% 。法兰由 26 gauge 镀锌铁组成。此系列产品可应用于工、商业、医院、学校、大楼和其它各种工厂空调设备,也可以安装于燃气轮机入风口设备或电脑室,以延长设备使用寿命。 一、产品选用要点 1.中效空气过滤器产品选用的主要控制参数额定风量、额定风量下的过滤效率、额定风量下的初阻力、容尘量及外形尺寸等。 2. 按JG/T22-1999《一般通风用空气过滤器性能试验方法》规定的方法检验,对粒径≥1.0μm微粒的大气尘计数效率≥20%而<70%的过滤器为中效空气过滤器。 3. 中效空气过滤器常用滤料有玻璃纤维、无纺布等。 4. 厂家应提供过滤器容尘量。 5. 中效空气过滤器初阻力应≤80Pa。设计时,可按初阻力的二倍为终阻力,作为过滤器的计算阻力。 6. 过滤器初阻力不得超过产品样本阻力的10%。可再生或可清洗的滤料再生清洗以后,效率应不低于原指标的85%,阻力不高于原指标的115%。 7. 空气过滤器应符合防火要求,空气过滤器的涂料闪点应不低于163℃。 8. 中效空气过滤器不宜独立使用,宜与粗效空气过滤器组合使用。 二、施工、安装要点 空气过滤器避免直接安装在淋水室、加湿器的下风侧,确实无法避开时应采取有效措施。 三、相关标准图集 07K505《洁净手术部和医用气体设计与安装》 四、执行标准 产品标准 GB/T14295-93《空气过滤器》 JG/T22-1999《一般通风用空气过滤器性能试验方法》 工程标准 GB50073-2001《洁净厂房设计规范》 GB50333-2002《医院洁净手术部建筑技术规范》 信息来源:空气过滤器

高效空气过滤器洁净区压差监测标准规程

高效空气过滤器洁净区压差监测标准规程 高效空气过滤器洁净区压差监测标准规程 一.目的: 建立高效空气过滤器洁净区压差监测标准规程,通过对HVAC系统回、排、新风风量调整,使洁净区压差控制符合国家标准高效空气过滤器的洁净度要求,并采取有效监控方法,确保洁净区压差处于良好受控状态,最终保证洁净区不受外来环境污染或洁净区之间的交叉污染。 二.范围: 本标准适用于精烘包30万级空气过滤器洁净区压差的调整、监控、纠偏处理。包括四层洁净区,分别为JK101、JK201、JK301、JK401。 三.责任者: 1、洁净区操作人员:负责对洁净区的压差进行日常监测、记录,并将每天测试结果、压差异常情况及时反馈到HVAC系统操作人员; 2、HVAC系统操作人员:负责对洁净区压差、空调机组初、中效过滤器压差进行监控和报告压差异常情况,并配合HVAC系统维护人员,对压差实行纠偏; 3、HVAC系统维护人员:负责对洁净区的压差进行测试与调整,并对洁净区压差超标时,实行纠偏处理; 4、洁净区管理人员:对本规程的实施负责,对洁净区压差实行预警,并确保压差计进行必要的校验; 4、质量科:负责按规程要求,实行监督管理。 四.程序: 1、压差调整原则:

1.1超高效空气过滤器洁净厂房必须保持一定的正压,使外界未经净化的空气不会进入净化区域,保证洁净度。通过对不同净化级别要求的净化区域,实行不同的压差控制,达到净化分区的作用; 1.2同一洁净级别的洁净区,由于生产工艺实际情况,部份房间会产生大量粉尘、有害气体、蒸汽等,在保证与外界环境呈相对正压的状态下,还应保证与相邻的洁净区呈相对负压,以防止粉尘、有害气体、蒸汽等扩散,污染其它洁净区域; 1.3洁净区压差控制,是通过房间的送风量与回风量或排风量之间的差值来保证的。但是,在任何情况下,房间的送风量绝对不能小于回风量或排风量,否则,会造成房间与外界环境成绝对负压; 1.4洁净区压差调整,就是在已确定的送风量状态下,通过调整回风量或排风量的大小,来确定洁净区与外界环境、洁净区内房间与房间、房间与洁净走廊之间的压差大小,确保符合设计要求; 1.5洁净区各洁净室维持正压差的压差风量,需要由室外新风补充。新风比应根据洁净区内总送风量、总回风量计算得出,并在压差调节前,先调节新风比符合设计要求。 2、压差控制标准: 2.1维生素B2原料药生产的精烘包洁净区,共分四层,每层分别由独立的HVAC系统进行送风,共四个HV AC系统; 2.2精烘包洁净区内是生产非无菌原料药,按洁净级别划分为30万级。洁净区内的生产操作,有部份房间产尘,如接料、混合、内包等。有部份房间产热,如精制。有部份房间产生气体,如稀释沉降、抽洗等。涉及到产尘、产热、产气的区域,安装有捕尘和强排设施; 2.3根据以上情况,确定精烘包洁净区压差控制标准如下: 2.3.1洁净区相对于室外的压差,应≥10Pa; 2.3.2洁净区内产尘、产热、产气等区域,相对于相邻的洁净区的压差,应保持相对负压。 3、测定调整前的准备工作 3.1HVAC系统的送风、回风、排风和新风调整平衡后,可进行压差调整; 3.2准备测量仪器。测量仪器的精度及量程应能满足测试需要,并进行校准,以保证测定数据的准确性。回风、排风的测量,采用热球式风速仪测量风速,并根据空气过滤器的截面积计算风量。压差的测量,采用便携式微压差计测量。 3.3准备设计参数表、送、回、排风平面图、风量测试与调整记录、压差测试记录等; 4、压差调整方法 4.1初测各房间的回风口的回风量、强排风量; 4.2按设计要求调整各回风口的回风量(具体的调整方法与HVAC系统空气平衡调节规程中,对送风量的调整方法相同); 4.3按设计要求,调整总回风阀,使总回风量符合设计要求; 4.4在送风、回风系统进行风量调整时,应同时测定与调整新风量,检查系统的新风比是否满足设计要求; 4.5总回风量符合设计要求后,采用压差计进行压差测定; 4.6在压差测定时,应保证洁净区各个房间门全部关闭,所有的强排、捕尘风机全部启动;

Camfil(康斐尔)空气过滤器中文版资料

Version 200306 Air Filters Datasheet 空气过滤器样本目录 请打开左侧 “书签”,选择您所需的空气过滤器。 clean air solutions Camfil Farr China (Shanghai) Rm 1403, Shanghaimart Tower, 2299 Yan An Road, Shanghai, 200336 Tel:021-********,Fax:021-******** 康斐尔中国(上海) 中国上海,延安西路2299号,上海世贸大厦1403室,邮编 200336电话:021-********,传真:021-******** http: //https://www.doczj.com/doc/1f8992188.html, http: //https://www.doczj.com/doc/1f8992188.html,

Product Version 30/30 CL2 -4" & 2" & 1" (G4) 200306 板式多褶预过滤器 Frame:Rigid high wet-strength beverage board. 外框:耐高湿型防水纸板 Media:Non-woven reinforced cotton&synthetic media 滤料:棉纤&化纤混合无纺滤料 Media support grid: welded steel wire, anti-corrosive. 焊接钢丝护网,表面防锈处理。 Efficiency: G4 (EN 779): 25%-30% ASHRAE 52/76过滤效率 > 95% @ (≥5um) Fire retardant grade: UL-2 listed. (UL 900) 防火等级 Humidity:≤ 100% RH 耐湿性: Recommended Max. Final Pressure drop: ≤ 225 Pa 建议最大允许终阻力 Applications: prefilters for commercial&industrial AHU. 主要应用: 商用和工业用通风空调系统的预过滤。 名义厚度名义尺寸 实际尺寸 (mm)过滤面积 风量 / 初阻力褶数 / 英尺 (英寸) (英寸 ") 高宽厚 (m2) (m3/h / Pa)(1英尺=305mm) 30/30 CL2 24 x 24 x 459459495 2.661700 / 183400/ 6830/30 CL2 24 x 12 x 459428995 1.30 850 / 181700 / 6830/30 CL2 24 x 20 x 459449295 2.201420 / 182840 / 684“ 30/30 CL2 20 x 20 x 449249295 1.821180 / 182360 / 6811 30/30 CL2 20 x 16 x 449239195 1.45 935 / 181870 / 6830/30 CL2 25 x 20 x 461949295 2.301480 / 182960 / 6830/30 CL2 25 x 25 x 461961995 2.901860 / 183720 / 6830/30 CL2 24 x 24 x 259459445 1.751700 / 203400 / 7030/30 CL2 24 x 12 x 2594289450.85 850 / 201700 / 7030/30 CL2 24 x 20 x 259449545 1.461420 / 202840 / 7030/30 CL2 24 x 18 x 259444545 1.311275 / 202550 / 7030/30 CL2 20 x 20 x 249549545 1.211180 / 202360 / 702” 30/30 CL2 20 x 18 x 249544545 1.091060 / 202120 / 7015 30/30 CL2 20 x 16 x 2495394450.97 935 / 201870 / 7030/30 CL2 20 x 12 x 2495289450.74 715 / 201430 / 7030/30 CL2 25 x 20 x 262249545 1.521480 / 202960 / 7030/30 CL2 25 x 18 x 262244545 1.371325 / 202650 / 7030/30 CL2 25 x 16 x 262239445 1.181180 / 202360 / 7030/30 CL2 24 x 24 x 1597597220.881190 / 202380 / 6330/30 CL2 24 x 12 x 1597292220.43 590 / 201190 / 6330/30 CL2 24 x 20 x 1597495220.74995 / 201990 / 631" 30/30 CL2 20 x 20 x 1495495220.60825 / 201650 / 6316 30/30 CL2 20 x 16 x 1495394220.48660 / 201325 / 6330/30 CL2 25 x 20 x 1622495220.761035 / 202070 / 6330/30 CL2 25 x 16 x 1622394 22 0.61825 / 201650 / 63 D W H

高效空气过滤器更换规程

副本编号:***制药厂

一.目的: 建立高效空气过滤器更换规程,以明确为生产环境提供洁净空气的高效空气过滤器技术要求、购买与验收、安装及检漏、洁净度测试,最终保证空气洁净度符合规定要求。 二.范围: 1、本标准适用于***制药厂精烘包车间药品生产过程中,用于为生产环境提供洁净空气的空气过滤系统中高效空气过滤器的更换规定,包括以下部位: 1.1HVAC系统(又叫空气净化系统); 1.2医药喷雾干燥塔进风过滤系统; 1.3医药气流粉碎进风过滤系统。 三.职责: 1、提取车间维修人员:按本标准要求,负责对高效空气过滤器的验收、存放,更换前的卫生清洁和更换,并配合检测人员检漏测试工作。 2、洁净区操作人员:按本标准要求,负责配合维修人员对洁净区卫生清洁和高效空气过滤器更换工作。 3、HVAC系统操作人员:负责按本标准要求,对高效空气过滤器安装前的空吹工作。 4、QC人员:负责对已安装的高效过滤器检漏、风量测试、洁净度检测,并出具测试记录。 5、医药工段长、提取车间主任:按本标准要求,负责对高效空气过滤器的购买计划申报,并组织验收、存放、安装、检漏、洁净度测试工作。 6、设备科:负责高效空气过滤器计划审核,并报公司设备部审批,记录收集与存档管理。 7、质量科:负责按本标准要求,对高效空气过滤器实行全过程监督管理。 四.引用文件 1、高效空气过滤器国家标准 GB13554-92 2、洁净厂房设计规范 GB50073-2001 3、洁净室施工及验收规范 JGJ71 90 五.定义: 1、高效空气过滤器(HEPA):由滤芯、框架和密封垫组成。在额定风量下,对粒径大于等于0.3um粒子的捕集效率在99.9%以上及气流阻力在250Pa以下的空气过滤器。 2、有分隔板过滤器:滤芯是按所需深度将滤料往返折叠制成,在被折叠的滤料之间靠波纹分隔板支撑着,形成空气通道的过滤器。 3、无分隔板过滤器:滤芯是按所需深度将滤料往返折叠制成,但在被折叠的滤料之间是用纸带(或线、线状粘结剂或其他支撑物)支撑着,形成空气通道的过滤器。 4、检漏试验:检查空气过滤器及其与安装框架连接部位等的密封性试验。 5、洁净度测试:即通过测定洁净环境内单位体积空气中含大于或等于某粒径的悬浮粒子

空气三级过滤器等级选用

空气三级过滤器等级 C、T、A、H精密过滤器 C级精过滤器(Q级) 特点:支撑螺丝;保持滤芯稳定不受震荡;多层玻璃纤维及完全过滤>3um的固态粒子及液态微粒,并具有减低压降功能;多孔式外部圆筒过滤后的空气由此迅速流至过滤器出口;内,外滤芯皆防腐蚀。油雾剩余含量3ppm. 应用范围:气动工具,马达,气缸的前置过滤;精密过滤器的前置过滤;吸附式干燥机的前,后装置;保护自动控制系统。 材质:陶质滤芯 过滤杂质:3um 滤油含量:3PPM 最高温度:65度 功能:将压缩空气内大量的油气滤除到3PPM以内及滤除杂质颗粒3um。 T级精过滤器(P级) 特点:支撑螺丝;保持滤芯稳定不受震荡;内部弹性海绵具有前置过滤功能;超细玻璃纤维特殊设计的密度,直径及表面处理可过滤的固态粒子及液态微粒;外部海绵层吸收并排出油雾。内,外滤芯皆放腐蚀,油雾剩余含量. 应用范围:对使用有油式空压机如精密仪器,喷漆,食品和药物包装及电子制造业提供无油的压缩空气;前置或后置过滤。 材质:多层玻璃纤维滤芯 过滤杂质: 滤油含量: 最高温度:65度 功能:将压缩空气内大量的油气滤除到以内及滤除杂质颗粒。 A级精过滤器(S级) 特点:内外滤芯皆防腐蚀;涂膜封闭式海绵套筒进行预过滤和气流分散;多层矩阵复合玻璃纤维特殊设计的密度,可过滤的固态粒子及液态微粒;油雾剩余含量. 应用范围:关键应用场合的无油空气供应,气接触产品的场合。空气相关产品,传输,搅拌,电子元件制造,氨替换;前置或后置过滤。 材质:多层玻璃纤维滤芯 过滤杂质: 滤油含量: 最高温度:65度 功能:将压缩空气中的微量油气精密滤除至以内同时空气中杂质颗粒至,达到无油标准的高制品压缩空气。 H级高效精过滤器(C级) 特点:内外滤芯皆防腐蚀,极精细活性炭粉稳定层滤除绝大部分油蒸气;特殊设计复合纤维介质粘合微精活性炭粉,滤除的固态粒子及微态微粒;复合纤维层防止活性炭微粒位移,外涂膜封闭式海绵网筒防止纤维游移;在额定运行条件下,设计寿命2000小时;油雾剩余含量. 应用范围:食品,饮料,医药,医院及药物工厂;呼吸用空气;潜水保证作业,活性炭过滤,用于工作环境除菌除臭。 材质:活性炭滤芯

高效空气过滤器更换标准

高效空气过滤器更换标准(整理版) 2011-05-14 高效空气过滤器的更换标准(整理版) 本文取自某公司的内部管理规范,仅供参考: 1.每年定期检测洁净区域的风量、以及其他环境参数,在测定的同时对高效进行检测。 2.主要检测风速、终阻力以及泄露率。 3.当高效空气过滤器的风量下降为额定风量的75%需要更换高效。 4.当终阻力为初阻力的2倍时需要进行更换。 5.当风速低于0.35m/s时需要进行更换 6.DOP pao等我司无法自测的项目可外请测试。 高效过滤器更换 相关解答如下: 1 高效过滤器的使用寿命影响因素太多(如生产车间的湿度、粉尘情况、空调系统的持续/间歇运行模式、厂房设施的维护保养情况等),笼统的制定更换周期确实难,GMP标准好像也没有具体要求。建议根据验证结果确定,HVAC属于

药品生产的关键系统,每年要进行一次再验证,根据测定的风速、高效过滤器的检漏等情况确定是否更换,不堵、不漏、不霉,尘埃粒子、沉降菌(浮游菌)监测符合要求则无需更换。 3 高效过滤器要下降到额定风量的75%更换的问题,没有哪个规定里有这一条,理论上你们先检测洁净度,洁净度不合格时才对高效进行扫描,风速也可以用风速仪测试,GMP规定高效风速小于0.35时高效必须更换,一般洁净室设计时的送风量是额定风量的60%-80%,另外一个参数就是阻力了,阻力测试比较麻烦,要到技术夹层将送风口钻一个孔,因为安装时不会每个高效送风口都装压差表,这样测试阻力大于初阻力2倍就要更换,如果设计时用484*484*220的过滤器,那设计时就有问题,按你们房间大小回风量算,也许320*320*220就够。 3 <洁净厂房设计规范>所规定的高效过滤器更换条件: 1) 气流速度降到最低限. 2) 阻力达初阻值2倍 3) 出现无法修补的渗漏. 4 关于第3条的解答:无论是高效还是初/中效,当投入使用,并在系统中调节符合我们使用要求时(如阀门开启量、送风机送风量回风量等参数确定)我们测定并记录下这是初中高效过滤器的各项参数,如风速、阻力,然后再下次检测时,我们在确定系统没有变化后,才再次检测他们的风速、阻力,从而才能判断是否更换空气过滤器。但现实中,我们很可能没有确定和固定过这些参数(如在每个阀门上标记其开启大小),而是看到压差不合格,就随意调节回风窗大小,有时甚至调节送风阀门的开启度,从而破坏了整个系统的平衡。有点扯远了,回来继续说高效,最实用的检测方法是1.扫描风速,确定高效没有堵,且风速均匀并达到需要值;2,然后进行泄露测试,确定没渗漏就基本上算检测合格了。这是目前国内比较认可的做法。但DOP价格很高,所以不太可能每半年测一次,另外还有堵塞高效的风险。所以才提出测阻力的方法。也就是在每个高效目端安装压差计,或者开测试孔。然后通过阻力变化来确定是否需要更换高效。并且可是实现自动化监控。这据说是国外目前的做法。他们这样做后,高效过滤器的使用寿命可以达到3年以上。而我们国内高效寿命基本上可能不到1年。原因除了高效本身质量外,还与我们使用方法、检测方法等关系极大。

空气过滤器各种分类的用途与特点

空气过滤器各种分类的用途与特点 空气过滤器主要用于进气净化,除去其中的尘粒。此外,某些生产过程的排气中含有细小的污染物质(如放射性物质、油雾等)这类净化虽然属于排气净化,由于它净化要求高,也需采用空气过滤器。进气净化的特点是处理空气中含尘浓度低、尘粒细,要求的净化效率高。 根据净化效率的不同,空气过滤器的分类及性能见表。 注:①一般过滤器采用大气尘计数法,高效过滤器采用DOP法。还可以根据空气过滤器的具体用途、特点和结构不同进行划分,如: (1)初效空气过滤器 用途:一般通风空气处理设备中的过滤段或新风系统的初级过滤。

特点:可自行更换滤料,纸框初效为一次性。 (2)折叠式中效空气过滤器 用途:通风系统的过滤。电子、制药、机械仪表、冶金、石油、化工、轻工、食品等领域的一般空气净化。 特点:效率高、容尘量大、占用空间小。 (3)袋式中效空气过滤器 用途:中央空调集中通风系统,或作为高效过滤器的前置过滤器,它可以减轻高效过滤器的负担,延长其使用寿命,也可用于工业领域的一般空气净化。 特点:阻力小、容尘量大。 (4)活性碳过滤器 用途:有效去除臭味、挥发剂、细菌、病毒及各种空气中的污染物,如油漆喷雾、烟雾、电子工厂及博物馆常见的污染物,以及食品加工厂和医院的臭气。 特点:高度发达的微孔结构,吸附容量高,吸、脱附速度快,净化效果好。使用活性炭过滤必须有前级过滤,否则,会由于空气中其它污染物而降低活性炭的效率。 (5)尼龙网空气过滤器 用途:空气质量要求不高的通风空调系统,或周围环境较恶劣,粉尘较高的场所作为初级预过滤。 特点:阻力小、易清洗、易维护。 (6)亚高效空气过滤器

空气过滤器

:::空气过滤器的详细介绍::: 空气过滤器的详细介绍 空气过滤器的详细介绍 1、空气过滤器(Air Filter) 超低洩漏空气过滤器(ULPA FILTER)高效率空气过滤器(HEPA FILTER)中性能空气过滤器(MEDIUM FILTER)初级空气过滤器(PRE FILTER) 2、空气过滤网箱体(Air Filter Unit)标准型高效滤网箱(HEPA UNIT、HEPA BOX) 抛弃型高效滤网箱(DISPOSABLE HEPA UNIT) 3、无尘室天井系统(C/R Ceiling System)天井吊架系统(HANGER SUPPORT SYSTEM)T-BAR 型天井系统(CEILING GRID SYSTEM)库板型天井系统(PANEL CEILING SYSTEM) 空气过滤器(Air Filter) 地址:深圳市光明新区观光路汇业科 技园10栋1楼东座邮编:518106 网 站备案:粤ICP备08004080号

电话:+86-755-29891998 传真:+86- 755-29891398 网址:https://www.doczj.com/doc/1f8992188.html, Email:sales@https://www.doczj.com/doc/1f8992188.html, :::无尘净化车间主要安装有那些净化设备::: 无尘净化车间主要安装有那些净化设备 第一,无尘净化车间进风系统要安装,新风过滤箱,中央净化空调(中央净化空调要分为初效/中效/高效三个过滤段)末端有高效送风口。有必要时还装有净化增压箱。 第二,无尘净化车间回风系统要安装,回风口,过滤初效器,中效回风箱。 第三,进入无尘净化车间之前先进入缓冲区,缓冲区门安装电子互锁,更衣处放置洁净储衣柜,空气清新机。 第四,人和货物进入无尘净化车间须经过,风淋室,货淋室,传递窗主要传递小物品。 第五,在无尘净化车间内局部需要达到10-1000级地方安装垂直层流工作台,层流罩(FFU),洁净棚(可移式净化工作棚),自净器。 第六,测试洁净室洁净度用,激光尘埃粒子计数器 无尘室测试方法及项目 为证明无尘室工作得令人满意,必须证明其满足了下述准则的要求: 1.无尘室内的空气是从洁净区向洁净程度差的区域流动,受污染空气的流动达到最低程度, 空气在门口处和室内建筑中的流动方向正确。 2.无尘室的送风量充足,足以稀释或消除室内产生的污染。 3.无尘室的送风不会显著增加室内的污染。 4.室内空气的运动状态可保证密室内没有高浓度聚集区域。 如果无尘室达到了上述这些准则的要求,就可以测量其粒子浓度或微生物浓度(必要时),以确定其达到了规定的无尘室标准。 无尘室的测试: 1.各区之间的气流控制:为证明各区之间气流运动方向正确,也就是从洁净区向洁净度差的区域流动,必须检测:(1)各区间的压差正确;(2)门口处或墙、地板等处的开口处气流运动方向正确,即从洁净区向洁净程度差的区域流动。 2.送风量与排风量:如果是紊流无尘室,那么就要测量其送风量与排风量。若为单向流无尘室,则要测量其风速。 3.空气过滤器检漏:对高效过滤器及其外框要进行检验,以保证悬浮污染物不会穿过。 4.隔离检漏:这项测试是为了证明悬浮污染物不穿过建筑材料侵入无尘室。 5.室内气流控制:气流控制测试的类型要依无尘室的气流模式——是紊流还是单向流而定。 若无尘室气流为紊流,则必须验明室内没有气流运行不足的区域。若是单向流无尘室,则必须验明整个室内的风速和风向是符合设计要求的。 6.悬浮粒子浓度和微生物浓度:如果上述这些测试满足要求,则最后对粒子浓度和微生物浓度(需要时)进行测量,以便验明其符合无尘室设计的技术条件。

高效过滤器的更换

高效空气过滤器的更换 过滤器, 空气 在下列任何一种情况下,应更换高效空气过滤器: 表10-6洁净室的净化空气监测频数 1、气流速度降到最低限度。即使更换初效、中效空气过滤器后,气流速度仍不 能增加。 2、高效空气过滤器的阻力达到初阻力的1.5倍~2倍。 3、高效空气过滤器出现无法修补的渗漏。 在更换净化空调系统中各级空气过滤器时应注意以下几个 问题: 6、末端过滤器更换后的综合性能检测 净化空调系统中热、湿处理设备、风机在与过滤器更换后,应起动系统风机使净化系统投入运行,并进行综合性能的检测,检测的主要内容为: 1)系统送、回风量、新风量、排风量的测定 系统送、回风量、新风量、排风量的测定,是在风机空气入口处 或风管上有风量测定孔处进行测定,并调整有关调节机构。 测定时所使用的仪器仪表一般为:毕托管和微压计或叶轮风速仪、热球 式风速仪等。

2)洁净室内气流速度及均匀性的测定 单向流洁净室,垂直单向流洁净室在高效过滤器下方10cm处(美国标准定为30cm)和距地坪80cm工作区水平平面上进行测定,测点间距 ≯2m,测点数不少于10个。 非单向流洁净室(即乱流洁净室)内气流速度,一般为测定送风口下方10cm处风速,测点数可根据送风口的大小适当布置即可(一般为1~5个 测点)。 3)室内空气温度和相对湿度的检测 (1)室内空气温度和相对湿度测定之前,净化空调系统应已连续运行至少24h,对于有恒温要求的场所,根据对温度和相对湿 度波动范围的要求,测定宜连续进行8h以上。每次测定间隔 不大于30min。 (2)根据温度和相对湿度的波动范围,应选择相应的具有足够精 度的仪表进行测定。 (3)室内测点一般布置在以下各处: a、送、回风口处 b、恒温工作区内具有代表性的地点 c、室中心 d、敏感元件处 所有测点宜在同一高度处,离地坪0.8m,也可以根据恒温区的大小,分别布置在离地不同高度的几个平面上,测点距外表面应大于0.5m。 4)室内气流流型的检测 对于室内气流流型的检测,实际是检查洁净室内的气流组织方式是否能满足洁净室洁净度的一个关键问题,如果洁净室内的气流流型不能满足气流组织的要求,则洁净室内的洁净度也不会或很难达到要求。

空气过滤器效率的测试方法

空气过滤器效率的测试方法 什么是空气过滤器的效率呢?过滤器捕集粉尘的量与未过滤空气中的粉尘量之比为“过滤效率”。 不同作业环境所要求的洁净等级不同,所以要采用不同效率的过滤器和相当的新风量才能满足不同的洁净度等级要求。 在决定过滤效率的因素中,粉尘“量”的含义多种多样,由此计算和测量出来的过滤器效率数值也就不同。实用中,有粉尘的总重量、粉尘的颗粒数量;有时是针对某一典型粒径粉尘的量,有时是所有粉尘的量;还有用特定方法间接地反映浓度的通光量(比色法)、荧光量(荧光法);有某种状态的瞬时量,也有发尘全过程变化效率值的加权平均量。因此,对同一只过滤器采用不同的方法进行测试,测得的效率值就会不一样,离开测试方法,过滤效率就无从谈起。 所以对不同的空气过滤器应分别采用不同的方法进行检测,选择过滤器时不能只考虑空气过滤器的效率还应该了解其试验方法和试验尘。 我国在世界上最早采用大气尘分组计数法试验过滤器的效率,并于1990年颁布了GB12218-1990《一般通风用过滤器性能试验方法》。 对于高效空气过滤器,各国的试验尘和试验方法差别较大,如我国颁布的GB/T6165-1985《高效空气过滤器性能试验方法、透过率和阻力》将油雾法和钠焰法作为法定的性能试验方法;英国采用钠焰法(BS3928-1969;)美国提出的DOP(邻苯二甲酸二辛酯)法。各国在提出试验方法标准基础上提出了空气过滤器的标准,如英国以DOP为试验尘的BS5295标准,欧洲空气处理设备制造商协会制定的EVROVENT4/9,国内外各种空气过滤器标准和效率比较见表3-3。 表3-3国内外各种空气过滤器标准和效率比较 我国标准欧洲标准EUROVENT4/9 计重效率(%) 比色法效率(%) 美国DOP法(0.3μ)效率(%) 欧洲标准EN779-1993 德国标准 DIN24185 粗效过滤器 EU1 <65 G1 A 粗效过滤器 EU2 65~80 G2 B1 粗效过滤器 EU3 80~90 G3 B2 中效过滤器EU4 ≤90 G4 B2 中效过滤器 EU5 40~60 F5 C1 高中效过滤器 EU6 60~80 20~25 F6 C1/C2 高中效过滤器 EU7 80~90 55~60 F7 C2 高中效过滤器 EU8 90~95 65~70 F8 C3 高中效过滤器EU9 ≥95 75~80 F9 亚高效过滤器 EU10 >85 H10 Q 亚高效过滤器 EU11 >98 H11 R 高效过滤器A EU12 >99.9 H12 R/S 高效过滤器A EU13 >99.97 H13 S 高效过滤器B EU14 >99.997 U14 S/T 高效过滤器C EU15 >99.9997 U15 T 高效过滤器D EU16 >99.99997 U16 C 高效过滤器D EU17 >99.999997 U17 V 国内外常用的空气过滤器的检测试验方法有: (1) 计重法

空气过滤器基本知识

过滤器知识 空气过滤器是空调净化系统的核心设备,过滤器对空气形成阻力,随着过滤器积尘的增加,过滤器阻力将随着增大。当过滤器积尘太多,阻力过高,将使过滤器通过风量降低,或者过滤器局部被穿透,所以,当过滤器阻力增大到某一规定值时,过滤器将报废。因此,使用过滤器,要掌握合适的使用周期。在过滤器没有损坏的情况下,一般以阻力判定使用寿命。 过滤器的使用寿命除了取决于其本身的优劣,如:过滤材料、过滤面积、结构设计、初始阻力等,还与空气中的含尘浓度,实际使用风量,终阻力的设定等因素有关。 掌握合适的使用周期,必须了解其阻力的变化情况,首先必须了解如下定义: 1. 额定初阻力:在额定风量下,过滤器样本、过滤器特性曲线或过滤器检测报告所提供的初阻力。 2. 设计初阻力:系统设计风量下,过滤器阻力(应由空调系统设计师提供)。 3. 运行初阻力:系统运行之初,过滤器的阻力,如果没有测量压力的仪表,就只能取设计风量下的阻力作为运行初阻力(实际运行的风

量不可能完全等于设计风量); 运行中应定期检查过滤器的阻力超出初阻力的情况(每个过滤段都应安装阻力监测装置),以决定何时更换过滤器。过滤器更换周期,见下表(仅供参考):

特别说明:低效率过滤器一般使用粗纤维滤料,纤维间空隙大,过大的阻力有可能将过滤器上的积尘吹散,这种情况下,过滤器阻力不再增高,但过滤效率降到几乎为零,因此要严格控制粗效过滤器的终阻力值! 确定终阻力要综合考虑几种因素。终阻力定的低,使用寿命短,长期更换费用(过滤器费用、人工费用,和废弃处理费用)相应就高,但运行能耗低,因此每种过滤器应该有最经济的终阻力值。 过滤器越脏,阻力增长越快。过高的终阻力不意味着过滤器使用寿命会延长,过高阻力会使空调系统风量锐减。过高的终阻力是不可取的。 顾客关于过滤器使用寿命短的抱怨:主要由三种原因造成 a、过滤器的过滤材料面积太小或单位容尘能力太小;

高效空气过滤器安装规范

高效空气过滤器安装规范 高效空气过滤器的安装应注意高效过滤器的安装密封,密封方法有接触填料密封、液槽刀口密封和负压泄露密封。相关标准: o《洁净手术部和医用气体设计与安装》 o GB/T13554《高效空气过滤器》 o GB/T6165《高效空气过滤器性能试验方法、透过率和阻力》 o GB50073《洁净厂房设计规范》 o GB50333《医院洁净手术部建筑技术规范》 一、高效空气过滤器产品特性及用途 普通高效空气过滤器是洁净系统中的一种空气过滤设备,它能对空气中粒径为0.3μm的微粒过滤效率达到99.99% 以上。主要应用于电子、医药、食品、精密仪器等高洁净度的行业。它的运输、安装等都必须严格按本要求进行,以确保过滤器能正确、合理使用。 二、高效空气过滤器搬运与贮存 1.在搬运过程中,必须按箱体的对角线方向搬运。搬运人要认真小心, 防止搬运时过滤器滑动,使滤网损坏。 2.不能有超过20kg以上的外力作用在过滤器上。在搬运时,双手及 其它物体绝对不能碰撞滤料,如不小心触及滤料,即使目视无损伤,也应再次扫描。 3.贮存地点应是温、湿差度小,清洁、干燥且通风系统良好的环境。

4.贮存期限超过三年以上的应进行重新测试。 三、高效空气过滤器安装与调整 1.高效空气过滤器应安装在常温、常压、常湿的环境中。如果工作条 件恶劣,必然使过滤器寿命缩短,甚至安装后不能正常工作。安装前应先检测过滤器外观有无变形、破损、滤料有无损伤,如发现以上情况应及时与销售公司联系。 2.安装过程中一定要注意过滤器与安装框架(或箱体)之间的密封性。 3.更换过滤器时必须把静压箱或送风管内壁四周彻底擦拭干净,以免 箱壁上的铁锈和尘粒等落在过滤器上,造成滤料破损。 4.安装时务必注意过滤器的气流方向,可按过滤器标签上风向标识“” 安装。箭头方向为过滤器出风面。 5.安装时用手托住四周边框,慢慢移进送风口内,不能用手和头顶住 滤料,以免滤料断裂,影响过滤效率(如图)安装时用手托住四周边框,慢慢移进送风口内,不能用手和头顶住滤料,以免滤料断裂,影响过滤效率. 四、高效空气过滤器使用寿命与维修 a.一般情况下,当过滤器的终阻力为初阻力的2倍时,应进行更换。 b.平时应定期对洁净区域进行洁净度检测,所检测的数据应满足洁净 厂房的设计要求。如达不到要求时,应对过滤器进行扫描以及对系统的密封性进行检查。如过滤器泄漏,则应补胶或更换。系统长期停用后再次使用时,应对洁净室进行扫描。

压缩空气过滤器级别

压缩空气过滤器 精密过滤器滤芯精细分级: C 主管路过滤器能除去大量的液体及3μm以上固体微粒,达到最低残留油分含量仅5ppm,有少量的水分、灰尘和油雾。用于空压机,后部冷却器之后,其它过滤器之前,作一般保护之用;用于冷干机之前,作前处理装置。 T 空气管路过滤器能滤除小至1μm的液体及固体微粒,达到最低残油分含量仅0.5ppm,有微量水分、灰尘和油雾。用于A级过滤器之前作前处理之用;冷干机和吸干机之后,进一步提高空气质量。 A 超高效除油过滤器能滤除小至0.01μm的液体及固体微粒,达到最低残油含量仅 0.001ppm,几乎所有的水分、灰尘和油都被去除。用于H级过滤和吸干机之前,起保护作用,冷干机之后,确保空气中不含油。 H 活性炭过滤器能滤除小至0.01μm的油雾及碳氢化合物,达到最低残油含量仅 0.003ppm,不含水分、灰尘和油,无臭无味。起最后一道过滤作用,供一些必须使用高质量高质量空气的单位,如食品工业、呼吸、无菌包装等。 我公司专业生产压缩空气精密过滤器(铁壳、铝壳)在消化吸收国内外先进技术的基础上,结合国内实际工况特点,有10公斤、30公斤、40公斤等各种压力和处理量的冷干机、吸干机、精密过滤器、气液分离器、后部冷却器等净化设备 为各类有油、无油空气压缩机提供最佳的后处理净化产品。 F9级主管路滤芯 可拆洗的不锈钢网状核心用离心力10U或更大固体及液体微粒,可替换的玻璃纤维完全过滤3U或更大固体及液体微粒,重力作用将水分带到滤器底部并排除油雾剩余含量5ppm。F7级主管路滤芯 滤芯内外层防腐蚀保护多层玻璃纤维及微纤维过滤1U以上固体及液体微粒,环氧聚脂保护的多层玻璃纤维聚洁油雾并过滤固态微粒油雾剩余含量1ppm。 F5级主管路滤芯 滤芯内外层防腐蚀保护多层玻璃纤维及微纤维,过滤大微粒,为下阶段过滤复合纤维层进一步聚洁微油雾,外层紧附海绵网套去除0.01u或更大固态及液态微粒,去除99.99+%微油雾,油雾剩余含量0.01ppm。 F3级主管路滤芯 滤芯内外层防腐蚀保护内外部弹性海绵层具有前置过滤功能符合微玻璃纤维特殊设计的密度、直径及表面处理超过精过滤油雾外层紧附海绵网套去除0.01u或更大固态及液态微粒,去除99.99+%微油雾,油雾剩余含量0.001ppm。 F1级主管路滤芯

过滤器标准

空气过滤器 1范围 本标准规定了空气过滤器(简称过滤器)的术语与定义、分类与标记、要求,试验方法、检验规则以及产品的标志、包装、运输和贮存等。 本标准适用于常温、常湿、包括外加电场条件下的通风、空气调节和空气净化系统或设备的干式过滤器。2规范性引用文件 下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而,鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。 GB/T191包装储运图示标志 GB/T1236—2000工业通风机用标准化风道进行性能试验 GB/T2423.3—2006电工电子产品环境试验第2部分.?试验方法试验C AB:恒定湿热试验GB/T2621 1—2006用安装在圆形截面管道中的差压装置测量满管流体流量第1部分:一般 用安装在圆形截面管道中的差压装置测量满管流体流量用安装在圆形截面管道中的差压装置测量满管流体流量

用安装在圆形截面管道中的差压装置测量满管流 体流量第4部分:文丘 GB—2005家用和类似用途电器的安全通用要求 GB/T4857.23—2003包装运输包装件随机振动试验方法 GB/T6167尘埃粒子计数器性能试验方法GB/T8170数值修约规则GB8624建筑材料及制品燃烧性能分级GB/T18883—2002室内空气质量标准 GB50243通风与空调工程施工质量验收规范3术语与定义 以下术语与定义适于本标准。 干式过滤器DRY TYPE FILTER 滤料既不浸油,也不喷其他液体的过滤器。 亚高效过滤器 SUB^HEP A(HIGH EFFICIENCY PARTICULATE AIR) FILTER 按本标准规定的方法检验,对粒径大于等于〇.5 /IM微粒的计数效率大于或等于95%而小于

空气过滤器的详细解析

洁净室产品网:https://www.doczj.com/doc/1f8992188.html,/ 空气过滤器 中文名称:空气过滤器英文名称:airfilter定义1:滤除压气机进口空气中的尘粒、盐分等杂质的设备。应用学科:电力(一级学科);汽轮机、燃气轮机(二级学科)定义2:能清除空气中灰尘及杂质的器件。应用学科:机械工程(一级学科);实验室仪器和装置(二级学科);气候环境试验设备-气候环境试验设备零部件及附件(三级学科)概述 在气动技术中,空气过滤器、减压阀和油雾器称为气动三大件。为得到多种功能,往往将这三种气源处理元件按顺序组装在一起,称为气动三联件,用于气源净化过滤、减压和提供润滑。三大件的安装顺序按进气方向依次为空气过滤器、减压阀、油雾器。三大件是多数气动系统中不可缺少的气源装置,安装在用气设备近处,是压缩空气质量的最后保证.其设计和安装,除确保三大件自身质量外,还要考虑节省空间、操作安装方便、可任意组合等因素。编辑本段空气过滤器的发展 空气过滤器的原型是人们为保护呼吸而使用的呼吸保护器具。据记载,早在一世纪的罗马,人们在提纯水银的时候就用粗麻制成的面具进行保护。在此之后的漫长时间里,空气过滤器也取得了进展,但其主要是作为呼吸保护器具用于一些危险的行业,如有害化学品的生产。1827年布朗发现了微小粒子的运动规律,人们对空气过滤的机理有了进一步的认识。空气过滤器的迅速发展是与军事工业和电子工业的发展紧密相关的。在第一次世界大战期间,由于各种化学毒剂的使用,以石棉纤维过滤纸作为滤烟层的军用防毒面具应运而生。玻璃纤维过滤介质用于空气过滤于1940年10月在美国取得专利。50年代,美国对玻璃纤维过滤纸的生产工艺进行了深入的研究,使空气过滤器得到了改善和发展。60年代,HEPA过滤器问世;70年代,采用微细玻璃纤维过滤纸作为过滤介质的HEPA过滤器,对013微米粒径的粒子过滤效率高达99.9998%。八十年代以来,随着新的测试方法的出现、使用评价的提高及对过滤性能要求的提高,发现HEPA过滤器存在着严重的问题,于是又产生了性能更高的ULPA过滤器。目前,各国仍在努力研究,估计不久就会出现更先进的空气过滤器。编辑本段过滤器本身的设计也取得了显著进展 其中最重要的是分隔板的去除,即无隔板过滤器的发展。无隔板过滤器不仅消除了分隔板损坏过滤介质的危险,而且有效地增加了过滤面积,提高了过滤效率,并降低了气流阻力,从而减少了能量消耗。此外,空气过滤器在耐高温、耐腐蚀以及防水、防菌等方面也取很大的进展,满足了一些特殊的需求。编辑本段空气过滤器的作用 从气源出来的压缩空气中含有过量的水汽和油滴,同时还有固体杂质,如铁锈、沙粒、管道密封剂等,这些会损坏活塞密封环,堵塞元器件上的小排气孔,缩短元器件的使用寿命或使之失效.空气过滤器的作用就是将压缩空气中的液态水、液态油滴分离出来,并滤去空气中的灰尘和固体杂质,但不能除去气态的水和油.编辑本段空气过滤器的工作原理空气过滤器的结构如右图所示从进口流入的压缩空气,被引进导流板(2 空气过滤器原理图 ),导流板上有均匀分布的类似风扇扇叶的斜齿,迫使高速流动的压缩空气沿齿的切线方向产生强烈的旋转,混杂在空气中的液态水油和较大的杂质在强大的离心力作用下分离出

空气过滤器详细介绍

空气过滤器详细介绍 一、空气过滤原理 粉尘与过滤介质的粘接力空气中的尘埃粒子,或随气流做惯性运动,或做无规则运动,或受某种场力的作用而移动,当运动中的粒子撞到障碍物,粒子与障碍物之间的范德瓦尔斯力使他们粘在一起。 过滤介质材料应能既有效地拦截尘埃粒子,又不对气流形成过大的阻力。杂乱交织的纤维形成对粒子的无数道屏障,纤维间宽阔的空间允许气流顺利通过。 目前广泛使用的材料有玻璃纤维、聚丙烯纤维、聚酯纤维、植物纤维等。 与粉尘撞击过滤介质的运动规律来解释,常见的过滤机理分为惯性原理、扩散原理、静电力。 大颗粒粉尘在气流中作惯性运动。气流遇障绕行,粉尘因惯性偏离气流方向并撞到障碍物上。粒子越大,惯性力越强,撞击障碍物的可能性越大,因此过滤效果越好。小颗粒粉尘作无规则的布朗运动.粉尘越小,无规则运动越剧烈,撞击障碍物的机会 越多,因此过滤效果越好。 空气中小颗粒粉尘主要作布朗运动,粒子越小,过滤器的效率越高;大颗粒粉尘主要作惯性运动,粒子越大,过滤器的效率越高。扩散和惯性效果都不明显的那部分粉尘最难过滤,对过滤器性能而言,过滤效率最低点的效率值最具代表性。 若过滤材料带静电或粉尘带静电,过滤效果可以明显改善。其原因主要有两条:静电使粉尘改变运动轨迹并撞向障碍物;静电力使粉尘在介质上粘得更牢固。 过滤器阻力被捕捉的粉尘对气流产生附加阻力,使用中过滤器的阻力会逐渐增加。被捕捉到的粉尘与过滤介质合为一体而形成附加的障碍物,所以使用中过滤器的过滤效率也会有所提高。被捕捉的粉尘大都聚集在过滤材料的迎风面上。滤料面积越大,能容纳的粉尘越多,过滤器的使用寿命就越长。 滤材上积尘越多,阻力越大。当阻力大到不合理的程度时,过滤器报废。有时,过大的阻力会使过滤器上已捕捉到的灰尘飞散,出现这种危险时,过滤器也该报废。过滤器阻力随气流量的增加而提高,通过增大过滤材料面积,可以降低穿过滤料的相对风速,以减小过滤器阻力。

相关主题
文本预览