当前位置:文档之家› Zemax笔记

Zemax笔记

Zemax笔记

Zemax笔记

1. Birefringent:

ZEMAX will trace the ordinary ray if the mode is set to 0 or 2. If the mode is set to

1 or 3, the extraordinary ray will be traced. ZEMAX cannot trace both rays at once,

however it is easy to create a multi-configuration lens with the mode set to 0 in configuration 1, and to 1 in configuration 2; this allows inspection of both possible paths as well as simultaneous optimization and layouts of the traced rays.

2. Surface type: P226

3. Coordinate Break:P239

If the "order" flag is set to zero, ZEMAX first decenters in x, and then in y.

Then ZEMAX tilts about the local z axis, then the local y axis, then the

local x axis.

4. Chapter 14 OPTIMIZATION:P385

5. MULTI-CONFIGURATION OPERANDS

GLSS :Surface # Glass.

MOFF : Ignored An unused operand, may be used for entering comments

PAR1: Surface # Parameter 1. Obsolete, use PRAM instead.

PRAM: Surface, Parameter Parameter value(This operand controls any of the parameters)

THIC: Surface # Thickness of surface.

6. Chapter 14 : Optimization, P385

ZEMAX uses an actively damped least squares method

7. heih