当前位置:文档之家› 5MCY设计计算书

5MCY设计计算书

5MCY设计计算书
5MCY设计计算书

5MCY14-1B

定量轴向柱塞泵设计计算书

5MCY14-1B定量设计计算书

一.泵的主体部结构如下图:

二.设计参数:

最高压力 Pmax=40Mpa

额定压力 Pmax=31.5Mpa

公称排量 q=5ml/rev

额定转速 n=1500r/min

使用介质 30#液压油

二.运动分析和动力分析

选取柱塞直径 d=10mm,柱塞分布圆半径R=14mm, 斜盘摆角γ=18°, 柱塞数Z=7

1.柱塞的最大行程:

L max=2RtgrCosωt=2×14×tg18°=9.1mm

2. 柱塞相对于缸体运动的最大速度:

V max=RωtgrSinωt

=14×(2×1500Л/60) × tg18°

=714.54mm/s=0.71m/s

3.塞运动的最大加速度:

a max=Rω2tgrCosωt=14×(2×1500Л/60)2×tg18°

=112239.01mm/s2=112.24m/s2

4.角速度: ω=2πn/60=2π×1500/60=157.1(1/s)

三.排量和流量

1.理论排量:q=1.57RZd2tg18°=1.57×1.4×12×7×tg18°=5ml/rev

2.理论流量: Q t=nq=1500×5/1000=7.5l/min

四.功率和扭矩

1.输入功率:N=P Q /612η总=320×7.51/(612×0.87)=4.13KN

2.输入扭矩:M=102N/ωηm=102×4.13/(157.1×0.95)=2.82kgf/m

五.缸体配流盘的平衡设计

1. 设计方法:采用剩余压紧力设计法

2.

选取缸体和配流盘腰形槽中心

直径 28,腰形槽宽度可取为柱塞直径的

13~1

2,配流盘内外密封带的宽度可取为柱塞直径的110~15

,根据测绘,初步确定缸体与配流盘的配流尺寸(配油盘如右图): R 1=0.975cm R 2=1.2cmm R 3R 4=1.8cm

3. 缸体配流盘的受力分析

a. 在三个柱塞压油时的压紧力与推开力 压紧力F

压=3×πd

2

4

p=3π×12×320/4=753.98kgf

推开力F 推=c π4

{(R 42-R 32)/ln(R 4/R 3)-(R 22-R 12

)/ln(R 2/R 1)}P =0.8π

4

[(1.82-1.62)/ln(1.8/1.6) -(1.22-0.9752) /ln(1.2/0.975)]×320

=0.8π4

(0.68/0.118-0.49/0.21)×320=689.64kgf c —考虑压油腔包角及一个柱塞刚跨入压油腔时的包角,选取三柱塞时C=0.8,四柱塞时C=1.05

压紧系数:M=F 压/F 推=753.98/689.64=1.09 剩余压紧力:F 剩=753.98-689.64=64.34kgf b. 在四个柱塞压油时的压紧力与推开力

F 压 =4/3×753.98=1005.31kgf

F 推 =C /C ×F 推=1.05/0.8×689.64=905.15kgf 平均剩余压紧力:

平均剩余压紧系数:M 均=F 压 /F 推 =1005.31/905.15=1.11 平均剩余压紧力:F 剩均=F 压 -F 推 =1005.31-905.15=100.16kgf

M≥1.0~1.1可以保证缸体与配流盘之间不脱开

四.滑靴的设计计算(滑靴如右图):

1.设计方法:采用剩余压紧力设计法

2.受力分析:

柱塞产生的液压压紧力

F压=πd2/4×P=π×12/4×320

=251.33kgf

选取密封带内径d1=8mm,密封带外

径d2=12mm

滑靴底面液压推开力

F推=π/4[(d1+d2)/2]2PCosα

=π/4[(0.8+1.2)/2]2×320×Cos18° =239.03kgf

压紧系数:M=F压/F推=251.33/239.03=1.05

剩余压紧力:F剩=251.33-239.03=12.3kgf

M≥1.0~1.1可以保证滑靴与斜盘之间不脱开

五.缸体强度计算

1.求出两缸孔之间的最小壁厚

β=[360°-4Zsin-1(d/4R)]/18

=360°-4×7sin-1(10/(4×14))

18

=(360°-288.02°)/18=4°

δ=2Rsinβ=2×14×sin4°=1.95mm

为考虑安全起见,本缸体仍采用厚壁筒

计算法,其最大应力

σ=0.1(d/2)2+1.3(d/2+δ)

2

(d/2+δ)2-(d/2)

2

×p

=0.1(1/2)2

+1.3(1/2+0.195)

2

(1/2+0.195)2-(1/2)

2

×320

=0.025+0.6280.48-0.25

×320=905.5kgf/cm 2<[σ]=800kgf/cm 2

2. 传动轴强度校核

(1)花键挤压应力σ=M

XZFD

cp

/2

= 2.82×100

0.8×4×[(1.5-1.17)/2-0.05]

×2.1×(1.5+1.17)/4

=546.68kgf/cm 2<[σ]=2000kgf/cm 2 式中:M-轴传送扭矩

X =0.8应力不均匀系数 Z-花键齿数

F-齿侧面积F =(D B -d b 2-C )×L i (C-花键倒角,L I 花 键长)

D CP =D B -d a 2花键齿中径 (2)轴的强度计算 b-b 截面的扭应力

τb =MW= 2.82×100

π/(16×1.17)×(1.174

-0.834

)

=1201kgf/cm 2<[τb ]=1500 kgf/cm 2 c-c 截面的扭应力 τC =MW= 2.3×100π/16×1.1

3

=1079kgf/cm 2<[τC ]=1500kgf/cm 2

2.5CY14-1B-111传动轴符合5CY14-1B 传动轴的设计要求,故可以

借用。

六.中心弹簧的计算

1.缸体和配流盘之间,滑靴和斜盘之间接触比压均应大于 1.0 kgf/cm2,

以防止泵吸入时密封面漏气。

2.使柱塞和滑靴回程的回程力:

泵在自吸时,低压的柱塞受以下力的作用:

a.柱塞和滑靴的惯性力,其最大值为

W=G/g×Rω2tgγ

=(0.011+0.0026)×9.8/9.8×0.014×(2π×1500/60)2×tg18°

=1.8N

其中:滑靴0.003kg 柱塞0.013kg

G-柱塞和滑靴的总重量kgf

g-重力加速度

f-柱塞对钢壁的磨擦系数,取f=0.08

△p-自吸时低压区柱塞两端的压力差

ω-缸体角速度

R.d-分别为柱塞分布圆半径1.4cm 柱塞直径1cm

b.柱塞和滑靴离心力对缸壁的磨擦力:

F f=G/g×rω2f

=0.016×9.8/9.8×0.014×(2π×1500/60)2×0.08

=0.45N

C. 柱塞两端压力差产生的轴推力:

根据自吸能力的标准,为125mmHg,即△p=125/760=0.164Kgf/cm

F△P=π/4×d2×△p=π/4×12×0.164×9.8 =1.26N

故一个柱塞需要最大的回程力为:

F z=W1+F f+F△p=1.8+0.45+1.26=3.51N

若中心弹簧的预压力为F S则F S≥ZF z=7×3.51=24.57N

3.泵空载时,中心弹簧的预压力必须能克服柱塞离心力F S对缸体产生的

倾复力矩。

F a=G/g×R×ω2=0.016×9.8/9.8×0.014×(2π×1500/60)2=5.5N M Z=Z/2×F a×R×tgγ

=7/2×5.5×0.014×tg18°=0.088N.m

则中心弹簧的预压力要防止缸体转动

F S≥M Z/r k≥0.088/0.021=4.19N r k缸体外径(半径)=21mm

4.中心弹簧的预压力必须能防止滑靴离心力引起滑靴的倾斜。

F S=ZF z≥ZF a e a/(h a tgγ+r c)Cosγ

=7×5.5×0.003/[(0.006tg18°+0.006)Cos18°]

=15.27 N

r c滑靴大圆半径R6mm

e a滑靴重心至柱塞球心距离≈3mm

F a滑靴的离心力

h a球心至滑靴端面距离6mm

所以,斜盘泵中心弹簧的预压力按上述四个条件,选择其中最大值作为弹簧设计的依据。

选取中心弹簧工作力: F S≥ 24.57N

从以上的弹簧设计工作力说明:2.5CY14-1B油泵的中心弹簧的弹簧力F=111.83N符合5MCY14-1B中心弹簧的弹簧力的设计要求。

参考书目录

雷天觉液压工程手册北京理工大学出版社 1998年12月

徐绳武 250SCY设计计算书济南铸锻机械研究所 1976年11月

徐灏机械设计手册机械工业出版社 1992年9月

钢板桩围堰设计计算书

钢板桩围堰设计计算书 1 工程概况 本方案陆地承台基坑开挖深度在3.0-5.0米之间,基坑开挖支护结构受力计算选择基坑最深、地质条件最差的最不利工况条件下进行受力计算。 本线路沿线地层以冲积、洪积、海积及海陆交互相沉积的粘性土、粉土、各类砂、软土为主,局部夹淤泥。 土层分层计算土压力,粘性土和粉土采用总应力法,即水土合算,强度指标采用快剪试验指标;对中、粗砂、碎石土,则应采用水土分算。 承台开挖高程范围内主要为人工填土、黏土、粉土,局部夹有淤泥质黏土,各土层已知条件:(1)人工填土:内摩擦角7?=?,粘聚力8kPa c =;(2)粘土:内摩擦角14?=?,粘聚力25kPa c =;(3)粉土:内摩擦角22?=?,粘聚力12kPa c =;(4)砂土:内摩擦角32?=?,粘聚力0kPa c =。土的天然重度γ取3 19kN/m 。非承压地下水位在地面下0.2~5.5处(承压水位不明)。 2 钢板桩围堰支撑结构受力计算 2.1钢板桩围堰 钢板桩围堰基坑开挖最大深度为5.0米,此类基坑承台最大高度为4.0米,设一道内支撑位于基坑底面以上3米,计算钢板桩围堰受力情况。 结合现场现有材料,拟采用WRU12a 钢板桩,其技术指标为:

单根钢板桩宽B=600mm,高H=360mm,厚t=9mm,每米截面积A=147.3cm2,单根钢板桩每米的重量69.5kg,每延米墙身每米的重量115.8kg,每延米墙身钢板桩惯性矩Ix=22213cm4,每延米的截面模量(抵抗矩)Wx=1234cm3,取钢板桩的允许拉应力σ=140Mpa,允许剪应力τ=80 Mpa。钢板桩长12m。由于钢板桩刚度较小,需加强内支撑。拟设置一道水平钢支撑,在距承台底面3.0m处设置,不设竖向支撑。水平钢支撑采用I40b型工字钢,沿钢板桩内壁设置长方形围檩,并在四角设置加强斜撑。 考虑施工堆载,假设基坑顶部(地面)作用有无限均布荷载q1=10kN/m2;在桩顶平台距离钢板桩桩顶2.0m处的坑外作用有宽度为0.6m的局部荷载(汽车荷载及其它荷载总和)q2=80kN/m2。 2.2计算作用于板桩上的土压力强度 依据《建筑基坑支护技术规程》(JGJ 120—99)第3.4~3.5节,计算土压力(水 平荷载及水平抗力)分布。土压力由四部 分组成:(1) 桩顶平台以下土自重引起; (2) 局部荷载(汽车荷载)q2=80kN/m2 引起;(3) 均布荷载q1=10kN/m2引起。 对人工填土、黏土及粉土地层,采 用水土和算法进行计算,在桩顶下2.0m 处设置一道内支撑,计算可得土压力分 布如右图所示。

毕业设计计算书

1 污水处理工程初步设计说明 1.1 设计要求 (1)设计规模 污水处理厂处理能力3015m3/d (2)设计进水水质 (3)设计出水水质 经污水处理工程处理后出水水质主要指标应达到《纺织染整工业水污 染排放标准》(GB4287-92)要求的一级水质标准,主要水质指标如表 2所示。 1.2工艺简介及工艺流程 针对*****生产废水和生活污水混合后形成综合废水的水质水量特征,采用以“絮凝沉淀—水解酸化池—交叉流好氧接触氧化池—脱色反应池”为主体的工艺对综合废水进行处理。其工艺流程图如下:

生产废水和生活污水先经过格栅、格网,截留一部份污水中悬浮物和漂浮物,保护后续水泵的正常工作,然后进入调节池;再经泵提升后,污水进入中和池,调节污水pH值;加入絮凝剂,出水进入初沉池沉淀大部分COD、SS和色度;出水流入水解酸化池,水解酸化池主要是分解大的有机物,然后进入二级

好氧池进行生物处理,二级好氧池主要是去除COD 、色度。从好氧池出来的水进入沉淀池进行沉淀,沉淀后的水进入生物活性炭池进行进一步脱色,达标后出水排放。生化污泥浓缩池的污泥一部份用于污泥回流,剩余污泥进入污泥浓缩池进行浓缩,浓缩后的污泥和物化污泥浓缩池的污泥通过带式压滤机进行脱水,泥饼外运,浓缩池的上清液及脱水的滤液则进入调节池。 2 主要构筑物计算 2.1筛网 设计说明 1选定网眼尺寸 污水中的悬浮物为纤维素类物质,所以筛网的网眼应小于2000um 。 2筛网的种类 根据生产的产品规格性能,选用倾斜式筛网,材料为不锈钢,水力负荷0.6~2.4m 3/(min*m 2) 3所需筛网面积A 参数 水力负荷q= 2.0m 3/(min*m 2) 设计流量Q=3015m 3/d=2.1m 3/min 面积 2.1 1.05 2.0 Q A q = ==m 2 设计取A=1.1m 2 2.2调节池 1在周期的平均流量为 33015125.625/24 W Q m h T = ==设计取130m 3/h 2水力停留时间t=8h

拱坝设计计算书

某拱坝设计计算书 一、工程概况 某水利枢纽正常水位相应库容982万m3;设计水位675.09m;校核洪水位676.01m,相应库容1027万m3。拱坝以50一遇洪水设计,500年一遇洪水校核。 二、拱坝坝高及体型设计 1.1坝顶高程计算: 拱坝中间为溢流坝段,两端为挡水坝段。溢流坝段为2孔泄流,孔口尺寸为7×4m,采用弧形闸门,堰顶高程为▽671.00m。 校核洪水频率P=0.2%,坝前校核洪水位▽676.01m,坝下校核洪水位▽595.72m。 设计洪水频率P=2%,坝前校核洪水位▽676.01m,坝下设计洪水位▽595.31m。 坝顶高于静水位的超高值 △h=h l+h z+h c h l——波浪高度(m)。 h z——波浪中心线至正常或校核洪水位的高差(m)。 h c——安全加高(m)。(《混凝土重力坝规范》P43)坝的安全级别为Ⅲ级,校核洪水位时h c=0.3m,设计洪水位h c=0.4m。 h l=0.0166V05/4D1/3 L=10.4(h l)0.8 V0——计算风速(m/s)

D ——风作用于水域的长度(km ),称为吹程。 相应季节50年重现期的最大风速为20m/s ,相应洪水期最大风速的多年平均风速为9.90 m/s 。吹程为0.4km 。 h z = L H cth L h l ππ22 H ——坝前水深(m ),校核洪水位H=73.41m ,设计洪水位H=72.49m 。 1.2校核洪水位时: h l =0.0166×9.945 ×0.431 =0.215m L=10.4 ×(0.215)0.8=3.041m h z = 041 .341 .732041 .3215.02 ππcth =0.048m △h=0.215+0.048+0.3=0.56m 校核洪水位坝顶防浪墙高:Z 校坝=Z 校核水位+△h Z 校坝=676.01+0.563=676.57m 1.3设计洪水位时: h l =0.0166×2045 ×0.431 =0.517m L=10.4 ×(0.517)0.8=6.135m h z = 135 .649 .722135 .6517.02 ππcth =0.137m △h=0.517+0.137+0.4=1.054m 设计洪水位坝顶防浪墙高:Z 设坝=Z 设计水位+△h Z 设坝=675.09+1.0555=676.14m 坝顶高程取以上结果较大值676.60m 。

建筑结构课程设计计算书

《建筑结构》课程设计计算书 --整体式单向板肋梁楼盖设计 指导老师:刘雁 班级:建学0901班 学生姓名:张楠 学号: 091402110 设计时间: 2012年1月 扬州大学建筑科学与工程学院建筑学系

目录 1、设计任务书———————————3 2、设计计算书———————————5 3、平面结构布置——————————5 4、板的设计————————————6 5、次梁的设计———————————8 6、主梁的设计———————————12

一、设计题目 整体式单向板肋梁楼盖设计 二、设计资料 1.扬州大学图书馆, 层高均为5.0米,开间5米,进深6.6米。试设计第三层楼盖。楼盖拟采用整体式单向板肋梁楼盖,混凝土强度等级为C30,钢筋采用HRB400。 2.楼面做法:楼面面层为20mm厚1:2水泥白石子磨光打蜡,找平层为20mm厚1:3水泥砂浆,板底为20mm厚混合砂浆抹灰。 三、设计内容 1.结构布置 楼盖采用整体式单向板肋梁楼盖方案,确定梁板截面尺寸。 2.板的计算 (1)确定板厚 (2)计算板上荷载 (3)按照塑性理论计算板的内力 (4)计算板的配筋

3.次梁计算 (1)确定次梁尺寸 (2)计算次梁上荷载 (3)按照塑性理论计算次梁内力 (4)计算次梁配筋 4.主梁计算 (1)确定主梁尺寸 (2)计算主梁上荷载 (3)按照弹性理论计算主梁内力,应考虑活荷载的不利布置及调幅 (4)绘制主梁内力包罗图 (5)计算主梁的配筋,选用只考虑箍筋抗剪的方案 (6)绘制主梁抵抗弯矩图,布置钢筋 5.平面布置简图

成果应包括: 1.计算书 (1)结构布置简图 (2)板和次梁的内力计算,配筋 (3)主梁的内力计算,内力包络图,配筋 2.图纸 (1)绘制结构平面布置图(包括梁板编号,板配筋),比例1:100(2)绘制次梁配筋图(包括立面、剖面详图),比例1:50,1:20 (3)绘制主梁弯矩包罗图、抵抗弯矩图及配筋图(包括立面、剖面详图),比例1:50,1:20 (4)设计说明

结构毕业设计计算书

目录 第一部分设计原始资料 0 第二部分结构构件选型 0 一、梁柱截面的确定 0 二、横向框架的布置 (1) 三、横向框架的跨度和柱高 (2) 第三部分横向框架内力计算 (2) 一、风荷载作用下的横向框架(KJ-14)内力计算 (2) 三、竖向恒载作用下的横向框架(KJ-14)内力计算 (10) 四、竖向活载作用下的横向框架(KJ-14)内力计算 (21) 第四部分梁、柱的内力组合 (28) 一、梁的内力组合 (28) 二、柱的内力组合 (30) 第五部分梁、柱的截面设计 (34) 一、梁的配筋计算 (34) 二、柱的配筋计算 (35) 第六部分楼板计算 (38) 第七部分楼梯设计 (40) 第一节楼梯斜板设计 (40) 第二节平台板设计 (41) 第三节楼梯梁设计 (41) 第八部分基础设计 (43) 第一节地基承载力设计值和基础材料 (43) 第二节独立基础计算 (43) 参考文献 (48) 致谢 (49)

第一部分 设计原始资料 建筑设计图纸:共三套建筑图分别为:某办公楼全套建筑图:某五层框架结构。 1.规模:所选结构据为框架结构,建筑设计工作已完成。总楼层为地上3~5层。各层的层高及各层的建筑面积、门窗标高详见建筑施工图。 2.防火要求:建筑物属二级防火标准。 3.结构形式:钢筋混凝土框架结构。填充墙厚度详分组名单。 4.气象、水文、地质资料: (1)主导风向:夏季东南风、冬秋季西北风。基本风压值W 0详分组名单。 (2)建筑物地处某市中心,不考虑雪荷载和灰荷载作用。 (3)自然地面-10m 以下可见地下水。 (4)地质资料:地质持力层为粘土,孔隙比为e=0.8,液性指数I 1=0.90,场地覆盖层为1.0 M ,场地土壤属Ⅱ类场地土。地基承载力详表一。 (5)抗震设防:该建筑物为一般建筑物,建设位置位于6度设防区,按构造进行抗震设防。 (6)建筑设计图纸附后,要求在已完成的建筑设计基础上进行结构设计。 第二部分 结构构件选型 一、梁柱截面的确定 1、横向框架梁 (1)、截面高度h 框架梁的高度可按照高跨比来确定,即梁高h=)8 1 ~121(L 。 h=)81~121( L 1=)8 1 ~121(×9200=767~1150mm 取h=750mm (2)、截面宽度 b=)2 1~3 1(h=)2 1~3 1(×750=250~375mm 取b=250mm 2、纵向连系梁 (1)、截面高度 h=11( ~)1218L 1=11 (~)1218×3600=300~200mm 取h=300mm (2)、截面宽度

工程结构课程设计计算书

辽宁工业大学 工程结构课程设计说明书 题目:工程结构课程设计(36组) 院(系):管理学院 专业班级:工程管理132班 学号:XXXXXXXXXX 学生姓名:XXXXXXXX 指导教师:XXXXXX 教师职称:教授 起止时间:2016.1. 4-2016.1.15 课程设计(论文)任务及评语 院(系):土木建筑工程学院教研室:结构教研室

目录 1.设计资料---------------------------------------------------------------1 2.楼盖的结构平面布置---------------------------------------------------1 3.板的设计-------------------------------------------------------------- 2 (1)荷载计算---------------------------------------------------------------2(2)计算简图--------------------------------------------------------------2(3)弯矩设计值------------------------------------------------------------3(4)正截面承载力计算-------------------------------------------------------3 4.次梁设计---------------------------------------------------------------4(1)荷载设计值-------------------------------------------------------------4(2)计算简图-------------------------------------------------------------- 4(3)内力计算---------------------------------------------------------------4(4)承载力计算------------------------------------------------------------5 5.主梁设计---------------------------------------------------------------6(1)荷载设计值-------------------------------------------------------------6(2)计算简图--------------------------------------------------------------6(3)内力设计值及包络图-----------------------------------------------------7

大桥钢板桩围堰设计及计算书

***大桥8#、9#墩承台钢板桩围堰设计计算书 1、工程概况 ***资水大桥是***至***公路工程中横跨资水的一座大桥,桥梁上部结构设计采用(6×30m)先简支后连续T梁+(58+95+95+58m)现浇变截面混凝土连续梁+(5×30m)先简支后连续T梁结构;主桥下部结构采用钢筋混凝土矩形门式桥墩,钻孔灌注桩基础,主墩墩身顺桥向宽为2.6m,横桥向为2个2.4m宽的墩柱,主墩承台厚度为3.5m,平面尺寸为11×9m,基桩采用直径Φ2.0m钻孔灌注桩。桥面宽度:2.5 m(人行道)+0.5m(路缘带)+10.75m(车行道)+0.5m(双黄线)+10.75m(车行道)+0.5m(路缘带)+2.5m(人行道)=28m,分两幅修建,桥梁中心桩号K5+873,桥梁全长为644m。 ***资水大桥设计洪水频率1/100,设计水位+179.4m,十年一遇洪水水位+172m,施工常水位+164m,近5年12月至4月最高水位+168m。8#、9#主墩基础位于资水河道内,主墩承台施工采用钢板桩围堰法,围堰考虑能满足在+168m 水位下施工。 2、计算依据 《钢结构设计规范》(GB50017-2014) 《简明深基坑工程设计施工手册》 《简明施工计算手册》 《***资水大桥施工图设计》 《***资水大桥工程地质纵断面》 《***资水大桥钻孔柱状图》 3、***资水大桥8#、9#墩钢板桩围堰检算 3.1围堰结构概况 8#、9#墩单个承台尺寸均为11m(横桥向)×9m(顺桥向)×3.5m(高度),下为4根Φ2.0m钻孔桩,桩基施工采用Φ2.4m钢护筒。承台施工采用钢板桩围堰法,钢板桩采用国产拉森Ⅳ型钢板桩,材质为SY295。 8#墩承台底标高为+161.498,顶标高为+164.998。钢板桩单根长度为9m,围堰平面尺寸为30×12m(考虑围堰四周各有1.5m操作及安装模板空间,双幅桥

钢框架结构计算书-毕业设计

摘要 该计算书为滨岛医疗中心门诊楼建筑方案及钢框架结构设计计算书,本设计依据建筑方案及给出的结构类型。参照规范有《建筑结构荷载规范》(GB 50009-2012)、《建筑抗震规范》(GB 50011-2010)、《混凝土结构规范》(GB 50010-2010)、《钢结构设计规范》(GB 50017-2003)等。完成设计内容有:建筑方案、结构平面布置、结构计算简图确定、荷载统计、内力计算、内力组合、主、次梁、柱选取及布置连接截面验算以及节点设计、楼梯设计、基础设计、工程概预算。结构类型为钢框架结构,梁、柱为钢梁、钢柱,板为组合楼板,柱脚采用埋入式,楼梯为板式钢筋混凝土楼梯、基础采用锥形独立基础。本计算书中列出了框架在恒荷载、活荷载、地震荷载、风荷载作用下的弯矩、剪力、轴力图以及内力组合表。 关键词结构设计;钢框架;独立基础;医用建筑

Abstract The calculations for the BinDao medical center clinic building steel frame building solutions and design calculations, based on the design and construction program structure given type. Design process based on structural loads standard (GB50009-2012) determine the structure of the load, in accordance with the Seismic Design of Buildings (GB50011-2010), design of steel structures (GB50017-2003) and the relevant requirements for structural design and calculation. The main work to complete the structure diagram layout and calculation of the identification, load statistics, internal force calculation and combination of primary and secondary beams and floor cross-section design and checking, node connection design, staircase design, basic design as well as project budget.Type of structure is steel frame structure, beams, columns of steel beams, steel columns, plates of composite slabs, column foot buried, reinforced concrete slab staircase stairs, independent foundation with a tapered base. Meanwhile, The calculations in the framework of the book lists the dead load, live load, seismic loads, wind loads bending moment, shear, axial force, and force combination table. Keywords Structural Design; Steel Frame;single footing medical building;

A江坝后式厂房双曲拱坝设计计算书

目录 第一章调洪演算 ........................ - 3 - 1.1 调洪演算的原理.......................................... - 3 - 1.2 调洪方案的选择.......................................... - 3 - 1.2.1对以下四种方案进行调洪演算......................... - 3 - 1.2.2方案比较........................................... - 7 - 1.2.3 2浅孔+2中孔方案选定后坝顶高程的计算 .............. - 8 -第二章大坝工程量比较 .................. - 10 - 2.1 大坝剖面设计计算....................................... - 10 - 2.1.1混凝土重力坝设计.................................. - 10 - 2.2 大坝工程量比较......................................... - 17 - 2.2.1重力坝工程量...................................... - 17 - 2.2.2拱坝工程量........................................ - 18 - 2.2.3重力坝与拱坝工程量比较............................ - 19 -第三章第一主要建筑物的设计 ............ - 19 - 3.1 拱坝的型式尺寸及布置................................... - 19 - 3.1.1坝型选择.......................................... - 19 - 3.1.2拱坝的尺寸........................................ - 19 - 3.2 荷载组合............................................... - 23 - 3.2.1 正常水位+温降 .................................... - 23 - 3.2.2 设计水位+温升 .................................... - 23 - 3.2.3 校核水位+温升 .................................... - 23 - 3.2.4 正常水位+温降+地震 ............................... - 23 - 3.3 拱坝的应力计算......................................... - 23 - 3.3.1对荷载组合1,2,3使用FORTRAN程序进行电算........ - 23 - 3.3.2对荷载组合4进行手算.............................. - 24 - 3.4 坝肩稳定验算........................................... - 37 - 3.4.1计算原理.......................................... - 37 - 3.4.2验算工况.......................................... - 38 - 3.4.3验算步骤.......................................... - 38 - 4.1泄水建筑物的型式尺寸 ................................... - 42 - 4.2坝身进水口设计 ......................................... - 42 - 4.2.1管径的计算........................................ - 42 - 4.2.2进水口的高程...................................... - 42 - 4.3泄槽设计计算 ........................................... - 43 - 4.3.1坎顶高程.......................................... - 43 - 4.3.2坎上水深h ........................................ - 43 - c 4.3.3反弧半径R ........................................ - 44 -

钢结构课程设计计算书

一由设计任务书可知: 厂房总长为120m,柱距6m,跨度为24m,屋架端部高度为2m,车间内设有两台中级工作制吊车,该地区冬季最低温度为-22℃。暂不考虑地震设防。 屋面采用1.5m×6.0m预应力大型屋面板,屋面坡度为i=1:10。卷材防水层面(上铺120mm 泡沫混凝土保温层和三毡四油防水层)。屋面活荷载标准值为0.7KN/㎡,雪荷载标准值为0.4KN/㎡,积灰荷载标准值为0.5KN/㎡。 屋架采用梯形钢屋架,钢屋架简支于钢筋混凝土柱上,混凝土强度等级C20. 二选材: 根据该地区温度及荷载性质,钢材采用Q235-C。其设计强度为215KN/㎡,焊条采用E43型,手工焊接,构件采用钢板及热轧钢筋,构件与支撑的连接用M20普通螺栓。 屋架的计算跨度L。=24000-2×150=23700,端部高度:h=2000mm(轴线处),h=2150(计算跨度处)。 三结构形式与布置: 屋架形式及几何尺寸见图1所示: 图1 屋架支撑布置见图2所示:

图2 四荷载与内力计算: 1.荷载计算: 活荷载于雪荷载不会同时出现,故取两者较大的活荷载计算。 永久荷载标准值: 防水层(三毡四油上铺小石子)0.35KN/㎡找平层(20mm厚水泥砂浆)0.02×20=0.40 KN/㎡保温层(40mm厚泡沫混凝土0.25 KN/㎡预应力混凝土大型屋面板 1.4 KN/㎡钢屋架和支撑自重0.12+0.011×24=0.384 KN/㎡ 总计:2.784 KN/㎡可变荷载标准值: 雪荷载<屋面活荷载(取两者较大值)0.7KN/㎡积灰荷载0.5KN/㎡风载为吸力,起卸载作用,一般不予考虑。 总计:1.2 KN/㎡永久荷载设计值 1.2×2.784 KN/㎡=3.3408KN/㎡可变荷载设计值 1.4×1.2KN/㎡=1.68KN/㎡2.荷载组合: 设计屋架时应考虑以下三种组合: 组合一全跨永久荷载+全跨可变荷载 屋架上弦荷载P=(3.3408KN/㎡+1.68KN/㎡) ×1.5×6=45.1872KN 组合二全跨永久荷载+半跨可变荷载 屋架上弦荷载P1=3.3408KN/㎡×1.5×6=30.07KN P2=1.68KN/㎡×1.5×6=15.12KN 组合三全跨屋架及支撑自重+半跨大型屋面板自重+半跨屋面活荷载

围堰计算(最终)-2

围堰安全专项施工方案施工计算书 计算: 校对: 复核: 2012年1月5日

拉森板桩围堰计算 介绍 对于水中拉森板桩围堰的计算,我们采用了迈达斯专业计算软件。 第一节、结构形式描述 根据设计形式,主桥中墩5#、6#在水中,计划采用拉森板桩围堰进行封闭施工。钢板桩围堰为方形,内轮廓平面尺寸52.0×11.0m ,高22m ,顶标高+3.5m ,入土12.9m ,设3道内支撑,封底厚度1.0m 。 钢板桩采用拉森Ⅵ型,围檩主梁第1道采用2I45b 、第2道及第3道采用2I63a 型钢梁,内支撑采用Φ630*8mm 钢管。 第二节、主要数据及相关参数 围堰用钢板桩为日本产SKSP-SX27型,即拉森Ⅵ型高强度钢板桩,单根宽度60cm ;截面参数如下表: 钢板桩结构 型号 (宽度×高度) 有效宽 W1 mm 有效高 H1 mm 腹板厚 t mm 单根材 每米板面 截面 面积 cm 2 理论 重量 kg/m 惯性距 Ix cm 4 截面 模量 Wx cm 3 截面 面积 cm 2 理论 重量 kg/m 2 惯性距 Ix cm 4 截面 模量 Wx cm 3 600×210 600 210 18.0 135.3 106 8630 539 225.5 177.0 56700 2700 钢板桩的机械性能如下表: 标准号 牌号 机械性能,不小于 屈服强度(N/mm 2) 抗拉强度(N/mm 2) 延伸率(%) JIS A 5528 SY295 295 490 17 根据钢板桩的进厂检验报告,试验屈服强度在380~405 N/mm2间。

钢板桩插打设备为美国ICE公司的28C-350E液压振动锤,锤宽30cm,设备自带动力,由振动锤和动力站两大部分组成,最大可提供116t的击震力和71t 的拔桩拉力。 28C-350E液压振动锤 第三节、主要计算 1、钢板桩围堰布置 主墩基础施工拟采用钢板桩围堰法。钢板桩采用拉森Ⅵ型钢板桩,材质SY295,单根长度为22m,围堰平面尺寸为52.0×11.0m,共设置三道内支撑。围堰顶高程为+3.5m,围堰底高程为-18.5m,承台底高程为-10m,封底混凝土厚1m。 2、钢板桩围堰施工步骤 (1)钻孔桩施工结束后打设围堰导向架及围堰施工平台,在靠近承台侧定位桩上焊接牛腿,安装第一道内支撑作为钢板桩插打导向围檩; (2)依次插打钢板桩至合拢; (3)围堰内抽水至-3.4m,在-2.4m处安装第二道内支撑; (4)围堰内抽水至河床底并挖土至-7.3m,在-6.3m处安装第三道内支撑; (5)第三道内支撑安装后采用挖掘机配合吊斗及人工,将围堰内基坑底面干挖清理至-11.0m; (6)搭设封底施工平台,采用泵车浇筑封底砼; (7)凿除桩头,施工承台; (8)承台模板拆除后,向钢板桩与承台间间回填细砂并在顶部浇注40cm厚

土石坝设计计算说明书

土石坝设计计算说明书 专业:水利水电建筑工程 指导老师:李培 班级:水工1303班 姓名:王国烽 学号:1310143 成绩评定: 2015年10月

目录 一、基本材料 (2) 1.1水文气象资料 (2) 1.2地质资料 (2) 1.3地形资料 (2) 1.4工程等级 (2) 1.5建筑材料情况 (2) 二、枢纽布置 (3) 三、坝型选择 (4) 四、坝体剖面设计 (5) 4.1坝顶高程计算 (6) 4.1.1 正常蓄水位 (6) 4.1.2 设计洪水位 (7) 4.1.3 校核洪水位 (8) 4.2坝顶宽度 (9) 4.3坝坡 (9) 五、坝体构造设计 (10) 5.1坝顶 (10) 5.2上游护坡 (10) 5.3下游护坡 (10) 5.4防渗体 (10) 5.5排水体 (11) 5.6排水沟 (11)

一、基本资料 1.1水文气象资料 吹程1km,多年平均最大风速20m/s,流域总面积2971km2。上游地形复杂,沟谷深邃,植被良好,森林分布面广,为湖北主要林区之一。 1.2地质资料 河床砂卵砾石最大的厚度达23m。两岸基岩裸露,支局不存在有1~8m厚的残坡积物。在峡谷出口处的左岸山坡,存在优厚1~30m,方量约150万m3 的坍滑堆积物,目前处于稳定状态。 1.3地形资料 坝址位于古洞口峡谷段,河谷狭窄,呈近似“V”型,河面宽60~90m。 1.4工程等级 本工程校核洪水位以下总库容1.38亿m3,正常蓄水位325m,相应库容1.16亿m3,装机容量3.6万kw,设计洪水位328.31m,校核洪水位330.66m,河床平均高程240m。混凝土面板堆石坝最大坝高120m。根据《水利水电枢纽工程等级划分及设计安全标准》DL5180—2003的规定,本工程为二等大(2)型工程。1.5建筑材料情况 坝址附近天然建筑材料储量丰富。砂砾料下游勘探储量318.5万m3,石料总储量21.86万m3,各类天然建筑材料的储量和质量基本都能满足要求。

课程设计计算书

四川理工学院课程设计 某综合楼给排水工程设计 学生:王玥 学号:12141020128 专业:给水排水工程 班级:2012级1班 指导教师:陈妮 四川理工学院建筑工程学院 二○一五年一月

四川理工学院 建筑工程学院课程设计任务书 设计题目:《某综合楼给排水工程设计》专业:给排水工程 班级:2012级1班学号:12141020128 学生:王玥指导教师:陈妮 接受任务时间 2014.12.01 教研室主任(签名) 1.课程设计的主要内容及基本要求 一.课程设计内容: (A)项目简介 根据有关部门批准的建设任务书,拟在某市修建一综合楼,地上9层,建筑面积约为8000㎡,建筑高度为28.50m。一层为商业用房,层高4.50米;二至九层为普通住宅,层高3.00米。 (B)设计资料 上级主管部门批准的设计任务书 建筑给水排水设计规范 建筑防火设计规范 高层民用建筑设计防火规范 自动喷水灭火设计规范 建筑设计资料 建筑物各层平面图等。 根据建筑物的性质、用途及建设单位的要求,室内要设有完善的给排水卫生设备。生活供水要安全可靠,水泵要求自动启闭。该建筑物要求消防给水安全可靠,设置独立的消火栓系统和自动喷水灭火系统。屋面雨水采用内排水系统。室内管道全部暗敷。 城市给水排水资料 1.给水水源 建筑以城市自来水管网作为给水水源。建筑物前面道路有一条市政给水可供接管,给水管管径DN200,常年水压不低于200Kpa。 最低月平均气温7℃,总硬度月平均最高值10德国度,城市管网不允许直接吸水。 2.排水条件 本地区有集中污水处理厂,城市污水处理率为85%,城市排水体制为雨水、污水分流制。市内生活污水需经化粪池处理后排入城市污水管道。本建筑右后方有一条市政污水管和一条市政雨水管预留的检查井可供接管。

钢板桩围堰计算书

津石高速公路(海滨大道-荣乌高速)工程第八标段围堰结构 检算报告 中铁四局集团有限公司设计研究院 2019年4月

津石高速公路(海滨大道-荣乌高速)工程第八标段围堰结构 检算报告 计算: 复核: 审核: 中铁四局集团有限公司设计研究院 建筑行业甲级铁道行业甲(Ⅱ)级市政行业甲级 二〇一九年四月

目录 一、项目概况 (1) 二、水文地质条件 (1) 三、计算依据 (3) 四、材料参数 (4) 五、围堰工况介绍 (4) 六、围堰计算 (5) 1、外侧围堰计算 (5) 2、内侧围堰计算 (12) 七、结论及建议 (18) 1、结论 (18) 2、注意事项 (19)

一、项目概况 津石高速公路是连接南部港区通往石家庄方向的重要通道,路线主线起自滨海新区南港工业区桩号K0+000,接已建的海滨大道及南港工业区港北路,经大港电厂南、东台子,止于西青区小张庄附近,接已建的津石高速和长深高速共线段桩号K36+500,全长约31.3公里。全线在南港工业区、大港油田、东台子、小张庄4处设置互通式立交。 本标段起点桩号为K29+730,路线沿独流减河北堤后侧台布设,跨越长深高速并设置小张庄互通立交,终点桩号为K31+150,路线长1420m。 本互通立交主线设计速度采用100Km/h,A、B、E、F匝道设计速度采用60Km/h,C、D匝道设计速度采用40 Km/h;主线为双向四车道,标准路基宽度27.5m;B、E匝道为单向单车道,标准路基宽度9m;A、C、D、F匝道为单向双车道,标准路基宽度10.5m。 其中A、F匝道位于独流减河河道中,河道水位标高为2.8m,本工程中钢板桩围堰是为了阻隔河水,以进行项目施工。 本工程钢板桩围堰位于独流减河中河水深度1m~5.2m,围堰采用12m双排钢板桩从河岸打设到河中央滩涂位置,上游、下游各打设一道,上、下游距离272m,每道长度360m,每道采用间距为4m的双排钢板桩形式,两排钢板桩中间抽2.5m水,保持内、外侧钢板桩水位差,确保钢板桩稳定。双排钢板桩围堰示意图见图1-1。 河面 内侧外侧 图1-1 双排钢板桩围堰示意图 二、水文地质条件

土木工程毕业设计计算书

1 工程概况 1、1 建设项目名称:龙岩第一技校学生宿舍 1、2 建设地点:龙岩市某地 1、3 建筑类型:八层宿舍楼,框架填充墙结构,基础为柱下独立基础,混凝土C30。 1、4 设计资料: 1.4.1 地质水文资料:由地质勘察报告知,该场地由上而下可分为三层: 杂填土:主要为煤渣、石灰渣、混凝土块等,本层分布稳定,厚0-0.5米; 粘土:地基承载力标准值fak=210Kpa, 土层厚0、5-1.5米 亚粘土:地基承载力标准值fak=300Kpa, 土层厚1、5-5.6米 1.4.2 气象资料: 全年主导风向:偏南风夏季主导风向:东南风冬季主导风向:西北风 基本风压为:0、35kN/m2(c类场地) 1.4.3 抗震设防要求:七度三级设防 1.4.4 建设规模以及标准: 1 建筑规模:占地面积约为1200平方米,为8层框架结构。 2建筑防火等级:二级 3建筑防水等级:三级 4 建筑装修等级:中级 2 结构布置方案及结构选型 2、1 结构承重方案选择 根据建筑功能要求以及建筑施工的布置图,本工程确定采用横向框架承重方案,框架梁、柱布置参见结构平面图,如图2、1所示。 2、2 主要构件选型及尺寸初步估算 2.2.1 主要构件选型 (1)梁﹑板﹑柱结构形式:现浇钢筋混凝土结构

图2、1 结构平面布置图 (2)墙体采用:粉煤灰轻质砌块 (3)墙体厚度:外墙:250mm,内墙:200mm (4)基础采用:柱下独立基础 2.2.2 梁﹑柱截面尺寸估算 (1)横向框架梁: 中跨梁(BC跨): 因为梁的跨度为7500mm,则、 取L=7500mm h=(1/8~1/12)L=937、5mm~625mm 取h=750mm、 4 7.9 750 7250 > = = h l n= =h b) 3 1 ~ 2 1 (375mm~250mm 取b=400mm 满足b>200mm且b 750/2=375mm 故主要框架梁初选截面尺寸为:b×h=400mm×750mm 同理,边跨梁(AB、CD跨)可取:b×h=300mm×500mm (2)其她梁: 连系梁: 取L=7800mm h=(1/12~1/18)L=650mm~433mm 取h=600mm = =h b) 3 1 ~ 2 1 (300mm~200mm 取b=300mm 故连系梁初选截面尺寸为:b×h=300mm×600mm 由于跨度一样,为了方便起见,纵向次梁截面尺寸也初选为: b×h=300mm×600mm

某江水利枢纽拱坝设计计算书毕业论文

某江水利枢纽拱坝设计计 算书毕业论文 目录 第一章调洪演算 (3) 1.1调洪演算的原理 (3) 1.2泄洪方案的选择 (3) 1.2.1 对三种方案进行调洪演算 (3) 1.2.2 对三种方案分别计算坝顶高程 (7) 1.2.3 对三种方案进行比较 (9) 第二章大坝工程量比较 (10) 2.1大坝剖面设计计算 (10) 2.2工程量比较 (16) 第三章第一建筑物——大坝的设计计算 (18) 3.1拱坝的剖面设计以及拱坝的布置 (18) 3.1.1 坝型选择双曲拱坝 (18) 3.1.2 拱坝的尺寸 (18) 3.2荷载组合 (19) 3.3拱坝的应力计算 (20) 3.3.1 对荷载组合⑴,⑵,⑶使用FORTRAN程序进行电算 (20) 3.3.2 对荷载组合⑷进行手算 (22) 3.4坝肩稳定验算 (31) 3.4.1 计算原理 (31) 3.4.2 验算工况 (31) 3.4.3 验算步骤 (32) 第四章泄水建筑物的设计 (38) 4.1泄水建筑物的型式尺寸 (38)

4.2坝身进水口设计 (38) 4.2.1 管径的计算 (38) 4.2.2 进水口的高程 (38) 4.3泄槽设计计算 (39) 4.3.1 坎顶高程 (39) 4.3.2坎上水深h c (39) 4.3.3反弧半径R (40) 4.3.4 坡度(直线段):与孔身底部坡度一致。 (40) 4.3.5 挑射角θ=20° (40) 4.4 导墙设计 (40) 4.5消能防冲计算 (41) 4.5.1水舌挑距 (41) 4.5.2冲刷坑深 (42) 参考文献 (45) 附录一 (46) 附录二 (47)

基础工程课程设计计算书

基础工程课程设计 说明书 二零一三年六月 土木工程

某框架结构条形基础设计计算书 一、工程概况 威海近郊五层两跨钢筋混凝土框架结构(相当于七层以上民用建筑),车间有三排柱,柱截面尺寸为400×600mm2,平面图如图1。作用在基础顶面的荷载特征值如表1,弯矩作用于跨度方向。室内外高差0.30m。 图1混凝土框架结构平面图 表1 荷载效应特征值 二、地质资料 1.综合地质柱状图如表2,地下水位在细砂层底,标准冻深为2m; 2.冻胀类别为冻胀。

表2 综合地质柱状图 三、设计要求 1.设计柱下钢筋混凝土条形基础; 2.计算该条形基础相邻两柱的沉降差; 3.绘制基础平面图(局部),基础剖面图,配筋图。 四、设计步骤 1.考虑冻胀因素影响确定基础埋深; 2.持力层承载力特征值修正; 3.计算基础底面尺寸,确定基础构造高度; 4.计算条形基础相邻两柱的沉降差; 5.按倒梁法计算梁纵向内力,并进行结构设计; 6.计算基础的横向配筋及翼缘高度; 7.绘制施工图。

五、工作量 1. 设计柱下钢筋混凝土条形基础; 2. 计算该条形基础相邻两柱的沉降差; 3. 完成课程设计计算说明书一份; 4. 完成铅笔绘制2号施工图一张; 5. 配合教师安排进行答辩。 六、内力计算 (一) 确定基础埋深 根据地质资料进入土层1.2m 为粘土层,其基本承载力特征值为147kPa ak f =,可知其为最优持力层,基础进入持力层大于30cm 。又有考虑冻胀因素的影响,根据规范可知,其设计冻深d z 应按下式计算:0 2.0 1.00.90.95 1.71m ...zs zw ze d z z ψψψ=???==,基础 埋深应在设计冻深以下,据此可初步确定基础埋深为2.3m 。根据基础埋深 2.3m>0.5m d =需进行持力层承载力特征值的深度修正,持力层为黄褐色粘性土层。液性指数 2618 0.50.853418 p L L p w w I w w --= = =<--,又0.70.85 e =<,查表可得,承载力修正系数0.3, 1.6b d ηη==,基础底面以上土的加权平均重度m γ= 317 1.2190.8 17.8kN/m 2.0 ?+?=, 条形基础的基础埋深一般自室内底面算起,室内外高差为0.3m ,取 2.30.3 2.6m d =+=, 则可得修正值为:(0.5)147 1.617.8(2.60.5)206.81kPa a ak d m f f d ηγ=+-=+??-=。 (二) 确定基础梁的高度、长度和外伸尺寸 根据规范要求,柱下条形基础梁的高度应该取为柱距的1/81/4倍 ,又有此处柱距取为6500mm ,故可得到基础梁的高度(1/81/4)6200(7751550)mm h =?=,取 1500mm h =,即为 1.5m h =。根据构造要求,条形基础端部外伸长度应为边跨跨距的1/41/3倍,故考虑到柱端存在弯矩及其方向,可以得到基础端部左侧延伸 1(1/4 1/3)(1/41/3)6200(1550 2067)m m l l ==?=,取1 2.0m l =。计算简图如图 2所示: